水冷變壓器 的英文怎麼說

中文拼音 [shuǐlěngbiàn]
水冷變壓器 英文
water cooled transformer
  • : 名詞1 (由兩個氫原子和一個氧原子結合而成的液體) water 2 (河流) river 3 (指江、河、湖、海、洋...
  • : Ⅰ形容詞1 (溫度低; 感覺溫度低) cold:冷水 coldwater; 你冷不冷? do you feel cold?; are you feeling...
  • : 壓構詞成分。
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  1. From the performance analysis of the inverter heat pump air conditioner, heat pump type vrf ( variable refrigerant flowrate ) air conditioning system, two - stage compression inverter air source heat pump, and cooling / heating / how - water inverter air source heat pump, the expanded function and performance improvement of air source heat pump from the variable frequency technology are analyzed in this paper

    摘要以頻熱泵空調、熱泵型vrf空調系統以及我們提出的雙級頻空氣源熱泵系統、供/供熱/供生活熱頻空氣源熱泵系統為研究對象,分析頻技術引入空氣源熱泵系統帶來的功能拓展和性能提升。
  2. The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method

    本論文從目前空調工程中使用的流量系統入手,研究了盤管換熱在部分負荷下流量與換熱量的非線性關系,分析了文獻中介紹的旁通管通流能力選擇的不足之處和一次泵系統採用差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次泵流量系統中差旁通控製法、回溫度控製法、負荷控製法的精確性,並得出了在一次泵系統的工況轉換時,採用負荷控製法能使機組及其相應泵在啟停時的負荷化范圍較小,更符合建築物的量需求,節能效果較好的結論。
  3. The condensed water separated from the air - conditioning system of an airplane is sprayed in the cold side of the radiator, and the heat transfer and the state change of water in the process of its spraying to the ram air are analyzed

    摘要將飛機空調系統中分離分離出的游離噴到散熱邊,並對噴到沖空氣中的狀態化過程和傳熱過程進行分析和計算。
  4. The sprayer is usually connected with water supply network, control value, detection alarm unit, etc. to form an automatic water spray system ( such as sprinkler fire - extinguishing system ) for saving electrical equipment, fighting burning flammable liquid, etc. it is widely used for fire control and cooling protection for such equipment / places as power plant * generating machinery, large size transformer, liquefied petrolatum tank, factory, shopping mall, hotel, warehouse, storied building and so on

    霧噴頭通常與供管網、控制閥門、控測報警等組成自動噴滅火系統(如雨淋噴滅火系統等) ,用來撲救電氣設備,可燃液體火災等,廣泛用於保護電廠的發電設備,大型,液體石油儲罐、工廠、商場、賓館、倉庫、樓房等必須滅火、控火或防護卻等場所。
  5. Resistance welding water - cooled transformers of the press - package and portable types - specification for portable transformers

    裝和便攜式電阻焊水冷變壓器.第2部分:便攜式規范
  6. Resistance welding water - cooled transformers of the press package and portable types - specification for press - package transformers

    裝和便攜式電阻焊水冷變壓器.第1部分:裝式規范
  7. There are five parameters need to be measured. there are five channels for input : the displacement of casting - roller, the rotate speed of casting - roller, the pressure of casting and rolling, the casting temperature and the water - speed of cooling water. they are measured by raster, photoelectric coder, strain pressure sensor, thermocouple and turboflowmeter

    系統需要進行監測的參數有五個,即有五路輸入信號:鑄輥位移、鑄輥轉速、鑄軋力、澆鑄溫度、流速,分別採用光柵、光電編碼、應力傳感、熱電偶和渦輪流量計作為檢測元件。
  8. At the same time, experimental study on boiling heat transfer by changing mass flow of refrigerant, mass flow of water, and inlet temperature of water was also finished. and then the performance of miniature evaporator was estimated

    本文完成了液單相、兩相熱平衡實驗和阻力特性實驗,研究了製劑在管內流動的降;同時進行了微型蒸發流動沸騰實驗,通過改劑質量流量、的質量流量、的進口溫度等,實現了對微型蒸發的性能評價。
  9. The shahe pumped - storage power station with two 50mw reversible units has been in good conditions on general since it was put into operation, but there still were some defects, such as the failure of unit ' s contemporaneous device, the insufficient cooling water discharge and pressure, and the failure of static frequency converter and excitation overcurrent

    摘要沙河抽蓄能電站兩臺50mw可逆式機組自投運以來,總體情況良好,但是也出現了一些缺陷,如機組同期裝置故障,機組流量或力不足,靜止故障,勵磁過電流故障等。
  10. Measurements were made of system pressure, mass flow rate of steam, air, and cooling water, temperatures of condensing flow and cooling flow, and the water level of boiler. the major phenomena observed in the present experiment are similar to those by other investigators. the mass flow rate of steam, the system pressure and air content are the most important factors affecting steam condensation

    實驗結果表明,維持二次側流量不,無論對于純凈蒸汽還是含有空氣的蒸汽凝,隨著蒸汽發生加熱功率的增大(即蒸汽流量增大) ,有效凝段長度將加長;當蒸汽中含有少量空氣,有效凝段長度也會明顯加長;提高系統力,有效凝段長度將縮短。
  11. This numerical simulation is not limited by number of cooler, winding at each pole, directed area, and horizontal duct in each directed area, and not limited by geometrical size of discs and ducts

    數值模擬對所配臺數、每柱線圈數、各線圈導向區間數、每區內平油道數以及線餅、油道的幾何尺寸沒有特別的限制。
分享友人