水式換熱器 的英文怎麼說

中文拼音 [shuǐshìhuàn]
水式換熱器 英文
steam-water type heat exchanger
  • : 名詞1 (由兩個氫原子和一個氧原子結合而成的液體) water 2 (河流) river 3 (指江、河、湖、海、洋...
  • : 名詞1 (樣式) type; style 2 (格式) pattern; form 3 (儀式; 典禮) ceremony; ritual 4 (自然科...
  • : 動詞1. (給人東西同時從他那裡取得別的東西) exchange; barter; trade 2. (變換; 更換) change 3. (兌換) exchange; cash
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  1. Based on the analysis of existing heat transfer models, design methods and experiences of the ground loop heat exchangers, a computer - aided design software is proposed. it can be used to design the horizontal loop, vertical loop and double - pipe heat exchangers

    在總結了國內外埋管設計經驗的基礎上,進行了埋管計算機輔助設計程序開發,該程序可用於平埋管、 u型埋管以及套管的設計計算。
  2. Based on the method of energy consumption, an analysis is given of the impact, which the dirt growth of a tube and shell sewage heat exchanger will have on transfer intensity, flow pressure drop and their energy losses

    本文運用力學能耗分析法,分析了管殼中軟垢的厚度對強度、流動壓降及其有效能損失的影響。
  3. Our main products are plate heat exchanger, unit heat exchanger, spiral heat exchanger, displacement heat exchanger, air radiator, welded plate heat exchanger, shell and tube heat exchanger, heat exchange boiler, etc

    公司主要產品有板機組、螺旋板、容積、空氣散、釬焊板、全焊板、列管、全自動等設備。
  4. Heat pumps and heat exchangers. devices for the recovery in the form of hot water of the energy coming from refrigerating equipment so called " heat recuperators "

    力泵和.以從致冷設備回收能量的裝置
  5. The fabricating procedure and quality control for thread lock heat exchanger were introduced. the quality of heat exchanger is satisfactory

    摘要主要論述了螺紋鎖緊環的製造工藝及質量控制方法,按此工藝和控制方法製造的質量優良,壓試驗一次成功。
  6. Heat exchangers - water to water heat exchangers for district heating - test procedures for establishing the performance data ; german version en 1148 : 1998

    .直接加.確定功率數據的測
  7. In the project hong kong international wetland park phase ii, we take the initiative to install the first geothermal heat pump air - conditioning system and utilize the wetland around as a source of heat and a heat sink. through 468 pairs of vertical geothermal pipe heat exchanger buried in the wetland, heated water from water - cooled refrigeration plants and cool water from water source heat pump are circulated in a common condenser water loop to exchange their energy directly

    在香港國際濕地公園第二期工程項目,我們率先採用了香港首個地源泵空調系統,利用公園的濕地作為一個源及能儲存,透過468對埋放在濕地的直立,將空調系統的受冷凝與地泵的凍直接交能。
  8. Through developing a 2 - dimensions heat transfer model of buried pipe - in - pipe heat exchanger and simulating the process by computer, the author figures out inter - relations of factors which influence characteristics of buried pipe - in - pipe heat exchanger, such as pipe diameter, pipe length, ratio of pipe diameters, flow rate, inlet water temperature, patterns of water inlet and outlet, and material features made of pipe, and proposes some optimizing indexes of buried pipe - in - pipe heat exchanger. the author studies the " heat - - short circuit " phenomenon as well and gives < wp = 5 > some important results

    本文通過建立地下套管埋管過程的二維傳模型,並藉助計算機對分析結果進行解析,弄清了影響埋管性能的管徑、管長、管徑比、通過流量、進溫度、進出以及管材等參數的作用,並提出了相應的優化指標,對研究界懸而未決的「短路」問題也進行了細致分析,得出了有關結論。
  9. Technical retrofit for the domestic water heating system in residential quater of one thermal power plant has been carried out by adopting the boosting and heating technology based on supersonic steam - liquid two - phase flow, to replace the original water pump and tube type heat exchanger

    摘要採用超音速汽液兩相流升壓加技術對某電廠福利區生活系統進行了技術改造,以取代原有的泵及管
  10. This thesis brings some new proposals for the computation of temperature rise in nature oil transformer. some useful formulas for convection calculation of vertical and horizontal duct are given. so temperature decrease at the surface of discs and temperature rise of oil flow can be obtained

    得到了較為適合的垂直油道、平油道自然對流特性數經驗關聯,並據此得到了自然油循環變壓垂直油道和平油道線餅表面溫降和油流溫升的計算方法。
  11. The way in which the mains pressure solar collector heats water is the same as the non pressure solar collector. rather than using the water in the tank directly, as the non pressure does, the type uses a 4560 copper coil

    這種和非承壓是一致的,但是它不直接用箱里的,它通過採用45 60圈的銅盤管
  12. The immersion electrical heater is chiefly applied in the direct contact mode of fluid heating. it features fast heat exchange and high thermal efficiency. it has the varieties of water heater, oil heater and gas heater. its heating element power density, i. e. the power per unit of heating area of the heating element, is an important parameter of the electrical heating element, which has a direct bearing on the performance and working life. the working out of the value is a highly specialized problem, being under the influence of many factors ( media flow rate, tempt, physical and chemical properties and direction in which the medium flows past the element etc )

    浸入電加主要用於直接對流體接觸加的場合,具有快,效率高等特點,分為用加、油用加、氣體用加,加元件的功率密度:即電加元件單位發面積上的功率,它是電加元件極重要的參數,直接影響加的使用性能及使用壽命,它的取值是一個非常專業的問題,受到許多因素的影響(如介質的流速、溫度、物理和化學性質及介質流過加元件的方向等等) 。
  13. It specifies the process of the design, simulation and experiment of liquid cooling system. main contents of the thesis are as follows : description of the present usage of liquid cooling system, presentation of a new type of liquid cooling system and description of its work principles ; design of the liquid cooling system, which mainly deals with the design and collating calculating of serpentine condenser and heat exchangers adopted in this system. meanwhile, the model chosen calculating of compressor 、 thermal expansion valve 、 plate evaporator 、 water pump and the like equipment used in the system are also carried out

    本文的主要內容如下:對液冷源使用現狀進行了描述,提出了一種新型液冷源系統並對其工作原理進行了闡述;對系統進行了設計,主要對系統中所採用的管帶冷凝側空/液進行了設計和校核計算,同時對系統中所用到的壓縮機、力膨脹閥、板蒸發泵等配套設備進行了選型計算;分別對製冷系統和冷卻液循環系統進行了數學建模。
  14. Rclying on the abundant technical strength of zhejiang university chemical machinery research instiute, it is specially engaged in the production of all kinds of the medical instruments such as the steam modular cylinder, modular dyeing tube, bactcricidal cylinder, gas storage cylinder, fermentation cylinder, heat exchanger, desk type, verticaltype, portable, horizontal electrically - hcated pressure steam sterilizer, carbon dioxide, biochemical, mycetes, illumination, water - sealcd, clectrically - heatedpressure steam sterilizer, dry heating sterilizer, carbon dioxide, bibiochemical, mycetes, illumination, water - sealcd, clectrically - heated, clectrically - heated constant temperature type culture box, fixed temperature and humidity box, climate cabinet exc. meanwhile it offers a full set of the stainless steel utensil serial products to the pharmaceuticals, health - care products, food, drink, cosmetics, uncontaminated workshops and so on. it can design and manufacture various non - standard equipments according to the consumer is requirements. welcome to make inquiry into this company. we are looking forward to cooperating with you

    本公司依託浙江大學化機研究所專業開發,製造各類:蒸汽定型罐、定型染色缸、殺菌罐、儲氣缸和發酵罐、、臺、立、手提、臥壓力蒸汽滅菌、乾滅菌、二氧化碳、生化、黴菌、光照、隔、電恆溫培氧箱、恆溫恆濕箱、人工氣候箱等醫療儀,同時提供製藥、保健品、食品、飲料、化妝品、潔凈車間成套不銹鋼具系列產品,還可根據用戶要求設計、製造各種非標設備,歡迎您的垂詢,期待您的合作!
  15. Presents the use of ice thermal storage technology in public buildings, the proper collocation and control of ice - coils, base - load refrigerating machines, dual - condition refrigerating machines, plate heat exchangers and circulating pumps, and the air conditioning system design when excess heat exists in inner zone

    摘要介紹了冰蓄冷技術在大型公共建築中的應用,冰盤管蓄冰槽、基載主機、雙工況主機、板和各種循環泵的合理配置和控制要求及內區有餘時的空調系統設計。
  16. According to the status of sewage in a pharmaceutical factory in harbin, uses the multistage spray heat exchanger in the sewage - source heat pump system

    摘要根據哈爾濱某制藥廠的污情況,在污泵系統中採用多級淋激作為污
  17. For the indirect cooling method, glycol liquid as the secondary coolant is cooled in the refrigerating unit, pumped to the cooler in the house to cool the air. the cooling load is regulated by changing the flowrate of the glycol liquid

    乙二醇間接製冷方是通過低溫鹽機組將乙二醇降到一定溫度,通過循環泵將乙二醇溶液供到需要製冷的氣調庫內中,再由對庫內環境進行製冷。
  18. The condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    建立了空氣冷卻實驗臺,管的加為電加,工質為蒸餾.在1 1模型上對分離管管內凝結特性、不凝性氣體對凝結的影響及不凝性氣體的擴散規律進行了試驗,得出分離管有一最佳充液率,其值為45 %左右;凝結系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離管的凝結僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結;隨著壓力的增加,不凝性氣體對分離管冷凝段的影響減少.這些結論可用於分離的工程設計和控制
  19. Abstract : the condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    文摘:建立了空氣冷卻實驗臺,管的加為電加,工質為蒸餾.在1 1模型上對分離管管內凝結特性、不凝性氣體對凝結的影響及不凝性氣體的擴散規律進行了試驗,得出分離管有一最佳充液率,其值為45 %左右;凝結系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離管的凝結僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結;隨著壓力的增加,不凝性氣體對分離管冷凝段的影響減少.這些結論可用於分離的工程設計和控制
  20. The model assimilates the latest results in the research and is solved by numerical approach which is called finite - difference equation 。 combined with experimental system, this model simulates the temperature of the water which comes from ground heat exchangers and the round temperature field

    結合實驗系統和傳模型,我們對製冷運行中地下的出溫度及周圍溫度場分佈進行了模擬分析,並給出了鉆孔的平均傳系數的公
分享友人