水泵出水管 的英文怎麼說

中文拼音 [shuǐbèngchūshuǐguǎn]
水泵出水管 英文
pumping line
  • : 名詞1 (由兩個氫原子和一個氧原子結合而成的液體) water 2 (河流) river 3 (指江、河、湖、海、洋...
  • : 名詞(吸入和排出流體的機械) pump
  • : Ⅰ名詞1 (管子) pipe; tube 2 (吹奏的樂器) wind musical instrument 3 (形狀似管的電器件) valve;...
  • 水泵 : water pump; compressed water pump水泵房 pump house; 水泵缸套 hoghead; 水泵工 plugman; 水泵間 [土]...
  • 水管 : waterpipe; water carrier; aqueduct; water conduit; water pipe; syphon; siphon (消防) 水管車 hos...
  1. Through calculating annual expenses and analyzing investment risk, an optimization model firstly put forward. the coefficient of investment profit of the irrigation system, which includes pipe distribution networks, drop irrigation device, is minimized. the coefficient is optimization design ' s target function which is by the genetic algorithms to solve

    在系統優化方面,單獨作為一個模塊用vc + +實現,本文首次提了以包括網、灌器、、電機等設備在內的微灌系統的益本比最大為目標函數,利用遺傳演算法求解的方法。
  2. The litter - resistance slowly closing butterfly check valve is developed a newest product based on our butterfly check valve, hydra - matic transmission to be add in the valve with unique design, new stuction and optimum performance, can be used pipeline of water supply and dring with such media : fresh water, sea water, sewage, raw water, ect. the valve should be installed at outlet of the water pump, in stapping the pump, the process of slowly closing after valve plate shuts rapidly. can be guard effectively against the destruction water hummer, so to ensure the safe operation of the pipline

    微阻緩閉蝶式止回閥是在我廠生產的蝶式雙瓣止回閥的基礎上利用能量轉換原理增設油壓緩閉裝置的新型模式止回閥,設計獨特,結構新穎,性能優宜,適用於凈,源,污,海等介質的供、排路中,安裝於口端,停時由於油壓阻尼作用法盤先速閉后緩閉,以消除破壞性錘,保證灌路安全運行。
  3. The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method

    本論文從目前空調工程中使用的變流量系統入手,研究了盤換熱器在部分負荷下流量與換熱量的非線性關系,分析了文獻中介紹的旁通通流能力選擇的不足之處和一次系統採用壓差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次變流量系統中壓差旁通控製法、回溫度控製法、負荷控製法的精確性,並得了在一次系統的工況轉換時,採用負荷控製法能使冷機組及其相應在啟停時的負荷變化范圍較小,更符合建築物的冷量需求,節能效果較好的結論。
  4. So the pipe system sends out noise because of resonance. especially the frequency 250hz of pulsating water is in close proximity to natural frequency of pipe, so the 250hz is a dangerous frequency to the pipe system. there is another reason why the noise is reached to 110db ( a ) in pump room that the noise is magnified by the cistern because of the resonance of cistern

    特別是激勵頻率為250hz的頻率分量恰好與道系統的固有頻率相接近,其引起的道振動對噪聲的貢獻最突,同時也與房房腔的固有頻率相接近,從而引起房腔共鳴發聲,使噪聲進一步被放大,以至於噪聲最大處高達105db ( a ) 。
  5. The centrifugal pump for oilfield waterflooding and oil transfer worked with low pump efficiency owing to unstable load and its energy loss is fairly large

    油田注集輸系統離心由於載荷經常變化,大多不能在其額定工況點工作,效低,且需要用口閥調節流量,產生一定的壓差,造成較大的能量損失。
  6. By this way, however, the working pressure of the fire water system will be at higher level in case of the central stabilizing high pressure system and undesirable consequences related to the pressure - acceptance of the pipe and the joints shall come forth

    而在集中穩高壓給系統中,這樣確定的穩壓揚程及設定壓力值,往往使消防給網始終處于較高壓力工況,因而使網內壓與道及其介面的承壓能力這一對矛盾趨于突
  7. H the high - raisepitch of pump also must install inverted - end valve at export - pipeline, to prevent the water - hammer of closed suddenly to destroy

    8揚程高的路上還應該安裝逆止閥,以防突然停機的錘破壞
  8. Based on optimization theories of genetic algorithms and the linear programming, a series of optimal design mathematics models and methods of water transmission conduits and water distribution networks have been presented, in the light of their characteristics. the results are as follows : 1 the linear programming models and calculations of the pressure gravity conduit, the gravity pressure conduit and channel, the pressure conduit with pump station and the pressure conduit in considering pump station flow variations are presented respectively

    本文針對不同類型的輸線和配網系統的特點,應用遺傳演算法和線性規劃等優化設計理論和方法,對其優化設計問題進行了較為系統的研究,成果如下: 1分別建立了重力輸道系統、重力輸渠系統、站加壓輸道系統以及考慮流量變化的站加壓輸道系統優化設計的線性規劃數學模型,並提了計算方法。
  9. Experimentation of sewage pumping station based on predictive control with vvvf is carried out. the experimentation result shows that the sewage pumping station predictive control system can be running under the condition of high water level. by using this control mode, inflow sewage is pumped out entirely

    在模擬研究基礎上,搭建了模擬試驗系統,在實驗室條件下,對污站排放系統進行了結合變頻調速的預測控制模擬試驗,試驗結果表明,採用預測控制,可以使系統運行在高位低揚程的工況下,使流入網的污等量排,實現了節能無污的控制目標。
  10. Results indicate that flow deviation in discharge passage is formed by co - action of pump outflow circulation and secondary flows in outflow curved pipe, hydraulic loss of discharge passage increases and pump assembly efficiency decreases because of flow deviation

    結果表明:流環量和二次流共同作用形成了流道偏流,偏流使流道力損失增大,裝置效率下降。
  11. This equipment is mainly composed of braising apparatus 、 condenser 、 balanced water tank 、 material pump 、 circulating pump of cooling water 、 double water - ring vaccum pump 、 connecting pipeline and electrical control box

    本設備主要由閃蒸器、冷凝器、平衡箱、、冷卻循環、雙級環式真空、聯接道及電器控制櫃等組成。
  12. A flap vlave used in pumping station is a kind of hydraulic - operated automatic gate, which is similar to a hinged check vaive. because of their simple structure and reliability, being able to shorten the length of outlet passage and facilitate the starting of pumping system in comparison with siphonic vacuum - distroied cutoff scheme. so it is propitious to be used and save investment but at the same time, flap valves always show some disadvantage

    因拍門簡單、可靠,與虹吸真空破壞截流閉鎖方式相比,可以縮短道(流道)長度,並利於系統起動,與快速閘門相比,拍門也有諸多優點,閘門門體易關閉不到位或卡住不能活動,因為門槽和?塊較軸孔容易殘留異物,閘門門體克服滑動阻力不僅無機械增益,且阻力和動力不在一直線上,門體易傾斜而自鎖,而拍門的工作可靠性則遠高於快速閘門。
  13. Points out that some designers only use empirical methods in determining the inner diameter of pipeline, calculating system resistance and selecting the rated flow and rated head of circulating pumps in water systems

    摘要指目前一些設計人員在設計空調系統時,僅根據經驗值估算道內徑、計算路阻力和選配系統循環的流量和揚程。
  14. From two sides of the design and construction, this paper expatiates the disposal of water supply and drainage pipelines, how to choose the pipe, the disposal of pump room and how to diminish the vibrancy of the pump groups

    從設計和施工兩方面發,論述了給排道的布置、給排材的選用及給房的減振隔聲等內容。
  15. This experiment include many contents, in a word, that is summer condition experiment, winter condition experiment > summer - winter transition condition experiment and winter - summer transition condition experiment, furthermore summer condition experiment still include flux changing experiment and winter condition experiment still include thermal balance experiment this article dealt with the data of the test, calculating out energy absorbing ( energy discharging ) of buried pipe in winter condition ( summer condition ), input power of heat pump x heat exchanging of piece buried pipe length x co - efficiency performance ? op ( energy efficiency rate ? er ) and average heat exchanging coefficient ; in additiont this article compares the inlet water temperature and outlet water temperature of underground the first layer and the second layer buried pipe when heat pump was running, the results are that the heat exchanging ability of the second layer buried pipe outgos the first layer buried pipe, and heat exchanging is more stable ; and still analyse earth temperature resuming in the transition season. the results are earth temperature resume fast in the first week when the heat pump runs off

    本文測試內容相當多,概括地說就是四個工況的測試,即夏季製冷工況的測試、冬季供熱工況的測試、夏?冬過渡季測試和冬?夏過渡季測試;另外在夏季工況的測試中還進行了變流量測試,在冬季工況的測試中還進行了熱平衡測試。本文對測試數據進行了處理,計算了冬(夏)季工況埋吸(放)熱量、熱空調器供熱量(製冷量) 、熱空調器輸入功率、埋單位長換熱量、供熱性能系數(製冷能效比)和平均傳熱系數等;另外,還比較了熱運行時地下一二層埋溫度變化情形,得地下二層埋換熱能力優于地下一層埋,且換熱很穩定;並分析了過渡季地下一二層埋溫度恢復情形,得系統停機一周內地溫恢復特別快。
  16. By citing distribution piping loss curve, analyses the two commonly used control methods of constant pump head and constant remote circuit differential pressure and considers that control with a constant remote circuit differential pressure is the better

    通過提輸配壓損曲線概念,從理論上分析了計量供熱變流量系統循環常用的恆揚程式控制制和恆定最不利環路壓降控制兩種方案,認為恆定最不利用戶資用壓力方案節能效果較好。
  17. According to actual requirement of tis for xinda pump factory, this paper puts forward a distributed structure and implementing scheme of technology information system based on three - layer mode, and explores some key technologies of software development. this paper ' s main conclusions are as follows : 1. aiming at the problems of present tis and its trends, a structure of cad / capp / cam system is presented in this paper based on component technology and integrated pdm

    本文以新達廠的生產理為背景,針對技術信息系統的實際需求,提了建立基於三層結構的分散式技術信息系統的體系結構和具體的實施方案,探索了軟體系統開發的關鍵技術,其主要成果如下: ( 1 )針對技術信息系統的發展趨勢及現有系統存在的問題,提了基於組件技術以pdm為集成工具的cad capp cam集成的體系結構。
  18. The function of the software is useful, it has provided many functions such as the calculate of crop water requirement, pipeline layout ( automatic layout and manual operation ) and its optimization, pipe diameter optimization. investment budgetary estimate and economic beneficial result can be result. and can rapid create plan and do plan comparison, the software provides many kinds of result output such as graph. text, table and so on

    該系統可以實行作物需量計算,系統設計流量推算、力計算、工程投資概算,經濟效益分析等功能,建立了常用的數據庫(材、件、和電機等)並對其進行理和維護,可以實現包括道布置、徑優化、材選擇等多種參數選擇在內的多種方案比較、優選。系統能提供圖形、文本、表格等多種形式的成果輸,人機交互界面友好,操作方便。
  19. The experimental method about pump setting characteristics with long discharge pipe

    帶長模型裝置特性試驗方法
  20. Analyze quantitatively chilled water with large temperature difference how to affect the performance and energy consumption of pump, chiller, fan - coil unit and surface air cooler and cooled water with large temperature difference how to affect pump, chiller and cooling tower. then put forward some remedy measures that can be adopted for good operation of large temperature deference

    定量分析了空調系統的冷凍大溫差對、冷機組、風機盤、表冷器的影響,以及冷卻大溫差對冷機組和冷卻塔的影響,從而提要使大溫差系統運行良好,需要採取的一些彌補措施。
分享友人