流體流道 的英文怎麼說

中文拼音 [liúliúdào]
流體流道 英文
fluid course
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • : 體構詞成分。
  • : Ⅰ名詞(道路) road; way; route; path 2 (水流通過的途徑) channel; course 3 (方向; 方法; 道理) ...
  • 流體 : [物理學] fluid; fluor流體力學 fluid mechanics; hydromechanics; 流體生物學 hydrobiology; 流體運動學 hydrokinematics
  1. On the basis of the hamilton ' s principle, the element mass matrix, stiffness matrix, and damping matrix caused by coriolis force of the finite method for the conveying fluid tubes were educed in the paper

    本文用哈密頓變分式推導輸送的有限元法分析單元質量矩陣、剛度矩陣和科里奧利力引起的阻尼矩陣。
  2. D. nwabunma, t. kyu, “ phase behavior, photopolymerization, and morphology development in mixtures of eutectic nematic liquid crystal and photocurable monomer ”, polymer. 42, 801 ( 2001 )

    劉光耀, 「光聚合高分子在微上的設計與製作」 ,國立成功大學,化學所碩士論文( 2004 )
  3. Measurement of fluid flow in closed conduits. velocity - area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current - meters or pitot static tubes

    密封管中量的測定.用電表或靜壓皮託管測量圓管內迴旋或不對稱量的速度-面積法
  4. Before assembling, inspect whether the fasteners are tight and make sure there are no foreign bodies blocked in the runner to avoid the damage to pump impeller and casing

    安裝前應檢查機組緊固件有無松動現象,泵內有無異物堵塞,以免水泵運行時損壞葉輪和泵
  5. Measurement of fluid flow by means of pressure differential devices inserted in circular cross - section conduits running full - venturi tubes

    用插入圓截面管中的壓差裝置測量量.文杜利管
  6. Measurement of fluid flow by means of pressure differential devices inserted in circular cross - section conduits running full - orifice plates

    用插入圓截面管中的壓差裝置測量量.節孔板
  7. Measurement of fluid flow by means of pressure differential devices inserted in circular cross - section conduits running full - nozzles and venturi nozzles

    用插入圓截面管中的壓差裝置測量量.噴嘴和文杜利噴嘴
  8. Measurement of fluid flow by means of pressure differential devices inserted in circular cross - section conduits running full - part 2 : orifice plates

    用插入滿載的圓截面管中的壓差裝置測量量.第2部分:節孔板
  9. Measurement of fluid flow by means of pressure differential devices inserted in circular cross - section conduits running full - general principles and requirements

    用插入圓截面管中的壓差裝置測量量.一般原理和要求
  10. Venturi measurement of fluid flow by means of pressure differential devices inserted in circular cross - section conduits running full - part 4 : venturi tubes

    用插入滿載的圓截面管中的壓差裝置測量量.第4部分:文杜利
  11. Measurement of fluid flow in pipes using vortex flowmeters

    用渦量計測量管
  12. Methods for measurement of fluid flow in closed conduits, using tracers - measurement of water flow - transit time method using radioactive tracers

    密封管量的示蹤劑測量法.第1部分:水量測量.第5節:放射性示蹤劑渡越時間法
  13. Methods for measurement of fluid flow in closed conduits, using tracers - measurement of gas flow - general

    密封管量的示蹤劑測量法.第2部分:氣量測量.第1節:總則
  14. Methods for measurement of fluid flow in closed conduits, using tracers - measurement of water flow - general

    密封管量的示蹤劑測量法.第1部分:水量測量.第1節:總則
  15. Specification for dimensions of omega clamps saddle clamps for fluid tubing installations

    裝置"形卡箍
  16. A mixture of three amino acids ( arg, gly, glu ) labeled with fluorescein isothiocyanate ( fitc ) was separated in pdms microfluidic chip, the separation voltage is 200v / cm, the separation time is less than 120 seconds ; according to ccd fluorescence images, two distinct physical processes - stacking and destacking during sample injection were studied qualitatively ; rhodamine b, a kind of temperature - dependent fluorescence dye, was used as probe to develop a temperature - fluorescence intensity equation, then temperature - color map in microchannels was constructed, and temperature trait in microchannels on the pdms microfluidic chip was analysed. according to the results, we conclude that the electric field applied to the pdms microfluidic chip should not exceed 400v / cm

    利用pdms微控晶元對fitc標記的精氨酸、甘氨酸、谷氨酸混合物進行了電泳分離,分離電壓為200v cm ,分離時間不到120秒;通過拍到的熒光顯微圖像對電泳注樣過程中復雜的樣品分子積聚與解聚現象作定性的分析;以熒光染料rhodamineb為溫度熒光探針,建立了pdms微控晶元上的溫度-熒光強度的關系公式,並利用matlab圖像處理工具箱構建出微內的溫度色圖,對pdms微控晶元的微溫度特性進行了分析,根據實驗結果,我們認為對于pdms微控晶元來說,在進行需要外加電場作用的試驗時,外加電場不應超過400v cm 。
  17. It has a long history using a throttle device to measure the flow volume of fluid in pipe the method has formed normalization at home and abroad the principle is to make the flow bunch form the particial shrink at the place where the throttle part is located so as to produce a static pressure difference then measure and calculate the flow volume at the moment when the fluid is flowing through the throttle device by the static pressure measured this method is based on the law of conservation of energy and the equation of flow continuity

    用節裝置測量管量已歷史悠久,在國內、國際上都已標準化,其原理是使束在節件處形成局部收縮,產生靜壓力差,通過測量靜壓力差來衡量過節裝置時的量大小,這種測量方法是以能量守恆定律和動連續性方程為基礎的。
  18. Methods for measurement of fluid flow in closed conduits, using tracers - measurement of gas flow - transit time method using radioactive tracers

    使用示蹤劑的密封管量的測量方法.氣量的測量.採用放射性示蹤劑的過渡時間法
  19. Because the operation in water hydraulic valves is controlled by flow fluid and the pressure drop results from energy loss of flow fluid past valve channel, the flow state of fluid in valves becomes the most important factor for the operational property of valves

    由於水壓閥是通過控制動來操作系統的,閥的壓降也來自於經閥時的能量損失,因此閥內的動狀態就成為決定閥操作性能最為重要的因素。
  20. When in experiment, the air was heated by the film heater installed on the above and below surface of channel, adopting various air velocity of flow, test import ' s and export ' s temperature, wall temperature, fluid flux and the drop of pressure, and the other parameter. adopting nu and nu0 to analyze the baffle ' s situation of heat transfer and fluid flow, which baffle was holed various diameters

    實驗時,通過矩形通上下壁面敷設的電加熱膜加熱通空氣,改變空氣速,測試不同工況時的進出口溫度、壁面溫度、量和壓力損失等參數,並採用無量綱努謝爾特準則數nu 、 nu _ 0等分析了設置不同開孔折板的換熱與動情況。