消弧線圈 的英文怎麼說

中文拼音 [xiāoxiànjuān]
消弧線圈 英文
arc extinguishing coil
  • : 動詞1 (消失) disappear; vanish 2 (使消失; 消除) eliminate; dispel; remove 3 (度過; 消遣) pa...
  • : 名詞1. [數學] (圓周的任意一段) arc2. (古代指弓) bow
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : 圈名詞1. (養豬羊等牲畜的建築) pen; fold; sty 2. (姓氏) a surname
  • 線圈 : [電學] coil
  1. According to the quickly adjustable characteristic of the peterson coil grounding system, this dissertation proposes a new control strategy. when the system is in operation, the strategy can limit the series resonance over - voltage by using the off - resonance method. when fault occurs, the strategy can conveniently suppressing arc by rapidly adjusting the inductance value of the peterson coil to the point, which the resonance with grounding capacitance of the power network is occurred

    依據可控硅控制消弧線圈接地系統的快速可控性,一改傳統的電網正常運行時調節消弧線圈接近於全補償的預調諧方法,提出正常運行時採用脫諧方法抑制串聯諧振過電壓;故障時立即調節消弧線圈電感量達到與對地電容諧振,以利熄的新型調節原理和方法。
  2. New designed auto tracing arc eliminating device based on this technique contents more technology, which has sample circuit, wide tuning scope, quick response and low noise. this paper firstly introduces neutral grounding histroy. by analyzing the syntony grounding theory, the transient and stable process of one - phase grounding fault, the threaten to secure run of power system and the importance of exact compensation for capacitive current are cognized

    論文中首先介紹了中性點接地方式的發展過程,通過對諧振接地原理和單相接地故障的暫態、穩態分析,認識到接地故障對系統安全運行的危害,通過消弧線圈對接地電容電流的迅速準確補償是減小故障危害的最主要手段。
  3. Analysing and restraining the surge current of tsc arc suppression coll

    消弧線圈的湧入電流及其抑制
  4. Based on researching the function of every kind of eliminating arc loop, new concept was brought up in this paper, and the protective device for eliminating arc and overvoltage was researched and manufactured. when the arc light connecting the ground emerges, the chip synthesizing controller control the vacuum contacter which can be operated with dividing phase and make its fault phase earthed so that the arc light can be dissolved thoroughly

    本文在研究各種消弧線圈的基礎上,提出全新的概念,研製出了及過電壓保護裝置,該裝置在出現光接地時,通過單片機綜合控制器控制一組可以分相操作的真空接觸器,使故障相接地,達到徹底光的目的。
  5. With this grounding method, the inductance value of the peterson coil can be adjusted quickly and continuously in real time

    採用這種接地方式,消弧線圈的電感量具有快速、連續可調節性。
  6. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  7. Then the idea of integral control of automatic resonance and single - phase earth faulted line selection was put forward

    並在此基礎上給出了補償電網中消弧線圈自動調諧與單相接地故障選一體化的綜合控制思路。
  8. Moreover, the epiipc functions properly and stably under well due to the reasonable electrical circuit design and very strong anti - jamming design. this design successfully solves the directionally power current leakage fault action and reject action, and makes it working in both neutral point non - grounded and grounded through resistors or coils under compensate systems and over compensate systems

    本次研製的保護器較好地解決了功率方向型漏電的誤動作和拒動作問題,使得它既能較好地運行在中性點不接地的系統中,又能用在中性點經消弧線圈接地的欠補償系統中,同時試用於過補償系統中。
  9. These measures include installation of lightning lines, decrease of the tower grounding resistance as far as possible, the reasonable use of arc suppressing coils and adoption of arresters

    處理方法包括加裝避雷、盡量減低路桿塔接地電阻值、消弧線圈的合理使用和採用路型避雷器。
  10. Development and application of the peterson coil device

    消弧線圈裝置的發展和應用
  11. Application and effect of arc suppressing wire coil in power distribution grid

    消弧線圈在配電網的應用及其效果
  12. Selecting principle analysis of damping resistance for multitap arc - suppression coil

    調匝式消弧線圈阻尼電阻的選取原則分析
  13. The arc - suppression coil with three - phases and five - columns system andits application in coal mine power network

    三相五柱式消弧線圈及其在煤礦電網中的應用
  14. In the end of this paper, the unsolved problem in this program is analyzed, and a conclusion is drawn

    文後分析了消弧線圈並聯運行控製程序尚未解決的問題,並做出結論。
  15. China ’ s 10kv distribution systems are almost grounded via the arc - suppression coil or not grounded systems

    我國10kv配電網大部分是中性點經消弧線圈接地系統或者中性點不接地系統。
  16. This method bases on the relativity of the current through zero order line and the sensible current through the perterson coil

    這種方法依據路零序電流與消弧線圈感性電流的相關性為基礎。
  17. Be based on distribution automation, the probability and feasibility of the parallel connection of arc - extinction coils is analyzed

    在配網自動化的基礎上分析了消弧線圈並聯運行的可能性和可行性。
  18. In mode selection of middle and large capacity units nowadays, there mainly have two types of peterson coil grounding and distribution transformer with resistor

    在現有大中型發電機中性點接地選擇上,主要有消弧線圈接地方式和接地變高阻接地方式。
  19. It has been proved by test results that this protective method is suitable not only for neutral point insulated system, but also for neutral point grounded system through arc suppression coil

    實驗結果表明:該保護原理不僅適用於中性點絕緣的供電系統,而且適用於中性點經消弧線圈接地的供電系統,提高了選擇性漏電的動作可靠性,保證了動作值的穩定性。
  20. It depends on many factors. in our country, middle and low voltage distribute net system uses non - direct - grounded system including no - grounded system and anti - arc system

    我國中低壓配電網多採用小電流接地系統,即中性點不接地或者經消弧線圈接地。
分享友人