消磁裝置 的英文怎麼說

中文拼音 [xiāozhuāngzhì]
消磁裝置 英文
degaussing apparatus
  • : 動詞1 (消失) disappear; vanish 2 (使消失; 消除) eliminate; dispel; remove 3 (度過; 消遣) pa...
  • : 名詞1. [物理學] (磁性; 能吸引鐵、鎳等的性質) magnetism 2. (瓷) porcelain; china
  • : Ⅰ名詞1 (服裝) dress; outfit; attire; clothing 2 (演員的化裝品) stage makeup and costume Ⅱ動詞...
  • : 動詞1. (擱; 放) place; put; lay 2. (設立; 布置) set up; establish; arrange; fix up 3. (購置) buy; purchase
  • 裝置 : 1 (機器設備的配件)installation; device; apparatus; equipment; arrangement; gear; appliance; rig...
  1. Meanwhile it can filter the waveform and gather the envelope and calculation the current peak and max steepness of lightning by length of erased magnetic record. thirdly we need analyze the difference of length of erased magnetic record between kinds magnetic tape or pre - recorded sine wave on magnetic tape, and finding the min and max lightning current that can be recorded by magnetic tape. then we confirm the type of the magnetic tapes and the way of installing which fit to the line towers

    同時對該波形進行濾波噪,提取包絡線計算長度和雷電流峰值及最大陡度第三部分根據mtlcd得出的數據分析不同雷電流通道下不同帶、不同預錄正弦波長度的差異及帶可以記錄的最小雷電流和最大雷電流,找到可以在輸電鐵塔角鋼上安使用的帶及其放方式。
  2. And we test how the laser ' s intensity changes with time through six kinds of cofe2o4 ionic magnetic fluid when laser has the same direction as the magnetic field ( be perpendicular to the magnetic fluid film )

    用相法設計了測試光效應一一透射光強的,測試了光線與外場方向一致(都垂直於性液體薄膜)的情況下,透過六種cofe 。 0 。
  3. The system eliminates the conventional rotating driving components, the absence of mechanical propeller system will lead to a reduction in the mechanical noise generated and make the arrangement of ship more expedient

    由於流體推進取了傳統的螺旋槳推進系統中的螺旋槳、傳動軸、減速齒輪等轉動,因此,它具有噪音小、布局靈活等優點。
  4. In this paper, based on analysis the distributing rule of permanent magnetic field, a novel method for dynamic tracing micro drug delivering device in alimentary canal has been proposed

    本文在分析永體空間場分佈規律的基礎上,提出了利用定位原理實現動態跟蹤微型藥物釋放化道運動狀態的方法。
  5. The basic principle of the method is that, when the micro drug delivering device mounted with a permanent magnet pass through the alimentary canal, the variety of magnetic field was detected by hall sensors, so the location of micro drug delivering device could be deduced and dynamic tracing can be achieved

    其基本過程是在微型藥物釋放上固定永體,當其通過化道時在體外檢測場變化,進而實時計算出微型藥物釋放的空間位,並描記出運動軌跡,實現動態跟蹤。
  6. The basic principle of biasing magnet automatic resonance regulated petersen coil and its operating condition at wuzhan substation were introduced

    摘要介紹了偏式自動調諧弧線圈在武漢市武展變電站運行的狀況。