無分流進樣器 的英文怎麼說

中文拼音 [fēnliújìnyàng]
無分流進樣器 英文
non split stream injector
  • : 無Ⅰ動詞(沒有) not have; there is not; be without Ⅱ名詞1 (沒有) nothing; nil 2 (姓氏) a surn...
  • : 分Ⅰ名詞1. (成分) component 2. (職責和權利的限度) what is within one's duty or rights Ⅱ同 「份」Ⅲ動詞[書面語] (料想) judge
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • : 進構詞成分。
  • : Ⅰ名詞1. (形狀) appearance; shape 2. (樣品) sample; model; pattern Ⅱ量詞(表示事物的種類) kind; type
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 無分 : no try
  • 流進 : inpour
  1. The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,

    基於基爾霍夫定律的電差動保護論對於何種形式的輸電線路都是一種簡單、可靠、選擇性強的保護形式,電力系統的發展使得電差動保護應用於線路保護成為需要,而電子、通信技術的發展使得電差動保護應用於輸電線路成為可能。首先,本文對目前線路保護的研究和實際應用情況行了討論和析,比較了常用線路縱聯保護的實現原理和實現條件及優缺點。其次,針對常規相量電差動保護易受正常負荷電和故障過渡電阻影響的缺點,同時為加快差動保護的動作速度,對基於故障量瞬時采值電差動保護的原理、判據、動作特性等作了討論和析,結果表明基於故障量瞬時采值電差動保護在可靠性、靈敏度、抗電互感飽和方面明顯優于常規相量電差動保護,對電差動保護各端的同步采方法和數據通信也行了析和評價。
  2. Non split stream injector

    無分流進樣器
  3. At the same time, the method of disposal phase shift of ct by compensation is introduced. then the analysis and statistic of electrical power quality, the control scheme and compensating amount of capacitor for reactive power compensation are analyzed respectively. and in the paper, the control with a / y and the switch with ac contactor and solid state switch is valid measure not only for improving operate level economically and amending electrical power quality but also for avoiding of replacing switch frequently and decrease economic loss

    然後對現有的演算法行了詳細的析、比較,篩選出既能滿足硬體要求又可降低投資、保證精度、簡化軟體的方案,確定了準同步采的方案,並通過對準同步采誤差的析,提出了一種從45開始采,從而提高精度的采數據處理辦法,同時,對于電互感相位漂移提出了一種補償辦法,接著對裝置中電能質量析與統計以及功補償中電容的補償量、投切原則也作了相應析,其中對于功補償採用y混合接線,並利用交接觸和固態開關共同投切電容,不但提高了經濟運行水平、改善了電能質量,而且有效的避免了頻繁更換開關,減少了經濟損失;最後,設計了裝置的硬體電路並繪制了相應的軟體程圖。
  4. Because of the difficulty to obtain the traffic flow information of lanes at non - detector intersections in most metropolises of the world, based on the relationships between the lanes of signal - controlled intersections, cluster analysis and stepwise regression are integrated to predict the traffic volume of lanes at non - detector isolated controlled intersections. first cluster analysis is used to cluster the lanes of non - detector isolated signal - controlled intersections and the lanes of all signal - controlled intersections with detectors. then, by the results of cluster analysis, the traffic volume samples are selected randomly and stepwise regression is used to predict the traffic volume of lanes at non - detector isolated signal - controlled intersections. the method is tested by the traffic volume data of lanes of the road network of nanjing city. the problem of predicting the traffic volume of lanes at non - detector isolated signal - controlled intersections was resolved and can be widely used in urban traffic flow guidance and urban traffic control in cities without enough intersections equipped with detectors

    針對目前國內外大中城市中普遍存在的檢測信號交叉口車道交通信息難于獲取的情況,基於信號控制交叉口車道之間的相關性,綜合應用聚類析和逐步回歸法預測單點檢測信號控制交叉口車道量.首先應用聚類析將單點檢測信號控制交叉口的車道與有檢測信號控制交叉口的車道交通行聚類,然後在聚類析結果的基礎上隨機選取車道交通本運用逐步回歸法預測單點檢測信號控制交叉口的車道量,此方法經過南京市的具體車道量數據驗證.此類問題的解決,可廣泛應用於城市交通誘導系統以及交通控制系統
分享友人