無功電壓降 的英文怎麼說
中文拼音 [wúgōngdiànyājiàng]
無功電壓降
英文
reactive drop- 無 : 無Ⅰ動詞(沒有) not have; there is not; be without Ⅱ名詞1 (沒有) nothing; nil 2 (姓氏) a surn...
- 功 : 名詞1 (功勞) exploit; merit; meritorious service [deed]: 戰功 military exploits; 立功 render me...
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 壓 : 壓構詞成分。
- 降 : 降動詞1. (投降) surrender; capitulate 2. (降伏) subdue; vanquish; tame
- 無功 : [電學] idle; idle work
- 電壓 : voltage; electric tension; electric voltage
-
Reactive power optimization is of great impotae to voltage quality twee, powerloss minimization and thus security and economic operation of power system
電力系統無功優化對保證電壓質量、降低運行損耗,實現電網的安全經濟運行具有重要意義。Accordingly, using graph theory and operating experience abroad for reference, it firstly brings forward a new method of voltage rectification which based on pilot bus with voltage control area in view of the weak coupling among every vca ( voltage control area ), using decomposing method of multi critical value, it realizes the eliminating vinculum of every vca. and then, the rectification starts by pilot bus voltage of every vca. so the resolution of whole power net is diverted into calculating smaller sub - net
由於各個電壓控制區之間無功電壓的弱耦合性,利用多閥值分解的分區演算法,實現區域間的解耦,然後根據各個子網路的主導節點的電壓進行校正,從而把求解整個網路的問題轉化為求解各個小的子網路,降低了網路維數,減少了無功設備控制動作次數,提高了校正成功率,縮短了計算時間。With the development of the electric power system, static - state reactive power compensators ca n ' t have met the requirements of the actual production and operation, and the trend to the fast and dynamic compensation for reactive power become greater and greater. since ertan hydroplant and 500kv transmission systems in sichuan power system have been operated, many power plants of load center are forced to halt during the high - water period, because the great deal of power is transmitted to far - distance load center. thus the load center loses voltage sustentation and the level of the system stabilization is debased greatly
四川電網的二灘水電站和500kv輸變電系統投入運行后,由於二灘水電站的大量電力遠距離輸送至負荷中心,迫使負荷中心的火電機組在豐水期大量停機,使負荷中心失去電壓支撐,大大降低了電網的電壓穩定水平;同時,因為四川電網中的無功補償裝置全為靜態無功補償電容器(或電抗器) ,這些設備只能在系統正常運行狀態下起到無功補償和電壓支撐的作用,而在電網出現事故時,不但不能起到電壓支撐作用,反而會促使電網電壓崩潰事故的發生。Firstly, the thesis briefly reviews the history of voltage and reactive power control technology, focusing on the defects of the equipment in use. then, with the theoretical analysis and the discussion on voltage and the characteristic of power system as well as the basic principle of voltage and reactive power control, the thesis makes a research on the character of voltage and reactive power control and interprets the controlling regularity of substation. in addition, with the consideration of the changes of transformer tips and the combined influence of capacity groups and reactive power and voltage, the thesis makes adjustment suggestion to the different operating - zones of voltage and reactive power
本文從降低網損和提高變電站自動化水平著眼,對變電站電壓無功控制應用方面的問題進行了研究,本文首先簡要回顧電壓無功控制的發展概況,著重指出了現有電壓無功控制裝置的缺陷;通過理論分析,在討論電力系統電壓、無功調節特點以及電壓無功總體控制原則的基礎上討論了變電站電壓、無功控制特性以及控制原理,給出了變電站電壓無功的控制規律;考慮了變壓器分接頭的變化及電容器組的投切對無功和電壓的綜合影響,針對電壓、無功的各種運行控制區域給出了相應調節策略。On account of the disadvantages of the feedback reactive power compensator, a device of its simplified scheme is studied in this paper, in which the reactive power is adjusted by regulating the voltage of the low - voltage side of the transformer
由於這種反饋式補償方案存在一些問題,本文分析了它的簡化形式,即通過調節降壓變壓器低壓側的母線電壓來調節濾波器的無功出力的補償方案。Placing facilities for reactive power compensation can reduce network loss effectively as well as improve transmission capacity and regulate voltage profile
在配電系統中加裝無功補償設備,可達到降低網損的效果,此外還可以提高電網輸送能力和改善電壓質量。The reactive power optimization of a radial distribution system can efficiently minimize the real power losses and improve voltage level of it, so that the yearly running charge will be reduced and the quality of power energy can be increased
配電網無功優化可以有效地降低網路有功損耗,提高系統的電壓合格率,從而降低網路運行費用,提高供電質量。Capacitors dispatch of distribution system is an efficient method to network loss reduction and voltage improvement in the distribution system operation. it is an important component of distribution automation system ( das ). the thesis mainly discusses reactive optimal control of distribution system
首先,研究了配電網無功優化控制的基本理論,討論了配電網無功優化控制對電壓和有功損耗的影響,提出配電饋線電容器優化控制對進一步降低配電網的有功損耗效果顯著。The electric power harmonic comprehensive control system with low cast and high security is applied in this article. it adopts that sourced compensation links with non - sourced compensation herewhich the former is realized by high frequency pwm control technology and the latter is carried out by crystal switch formed by non - flow and over - voltage. it can realize stepless modulation with imaginary power, mightiness compensation of harmonic and negative electricity, and circuitry consumption debasing are achieved
提出採用有源補償與無源補償相結合的電力諧波綜合治理技術及裝置,無源部分採用無涌流和過電壓的晶閘管控制電容器技術實現,有源部分採用高頻pwm控制技術實現,成本低、可靠性高、可實現無功功率的無級調節、強力補償諧波電流和負序電流,降低線路損耗。Aiming at the fact that power factor of low - voltage power equipment is very low in china and application condition of fieldbus technology in the world, based on enhancing power factor of ac motor, lowering losses of the reactive power, improving power quality, therefore, it is of great significance and practical value to research the reactive power compensation by applying the technology of fieldbus, computer and power electronics
針對目前國內低壓設備用電負載功率因數偏低和國內外現場總線技術的應用現狀,基於提高交流電機的功率因數、降低無功功率損耗和改善電能質量,本文綜合運用現場總線技術、計算機技術和電力電子技術對交流電機無功功率補償的有關方面進行了研究,其研究成果具有一定的理論意義和實用價值。Aimed at conquering the local - searching shortcoming in ga, after establishing fuzzy regulation scale of normal voltage, a socalled on - site regulation expert anowledge based on the plantrstation concept in power systemis implemented to eliminate voltage / reactive power overlimit, to amer decrease investinentand to minimiting active power loss. 2
在給出合格電壓的模糊調整裕度的基礎上,提出採用基於廠、站概念的就地調整的專家規則進行輔助變異決策,以增強遺傳演算法的局部收斂性;所採用的專家規則主要包括越限校正、進一步減少無功設備投資和降低網損三個方面。Abstract : the underground load characters in yinshan mine were analyzed. based on the technical features of various kinds of reactive compensation devices, it was proposed that low voltage capacitance dynamic compensation mode shall be adopted for compensating reactive power and lowering voltage fluctuation
文摘:對銀山鉛鋅礦井下負荷性質進行了分析,根據各種無功補償裝置的技術特點,提出採用低壓電容動態補償方式對該礦井下無功進行補償和降低電壓波動。In order to ensure the whole system operate economically, power department equip transformer with onload tap changer and shunt capacitors for most distribution substations, according to the operating condition, adjusting the position of transformer taps and capacitors can control the variation of voltage and reactive power exchanger of distribution substations and power system in certain extent
為確保整個系統運行經濟性,降低網損,電力部門在大多數變電站配置了有載調壓變壓器和並聯補償電容器組,根據運行情況適當調節變壓器分接頭的位置和投切並聯補償電容器組,可以降低電壓變化和變電站與系統的無功交換控制在一定的范圍內,確保供電質量和電網運行的經濟性。Reactive power and voltage control in the distribution systems is very important. it makes the running of the systems more safe and stable and economical. it can also decrease the real power loss and improve the voltage
在配電系統中進行無功電壓控制能夠有效地降低有功功率損耗、改善電壓水平,對系統的安全穩定經濟運行具有重要意義。Fuzzy security constraints, such as voltage and generator ' s reactive power output, are introduced in qp model, and a new ipm with fuzzy constraints is deduced in detail, being the critical program in quasi real - time voltage / reactive control. 4
根據我國電網當前的自動控制水平以及實時無功/電壓控制的認可程度不高的實摘要際情況,提出首先實現電網的準實時無功電壓控制,以提高運行電壓合格率、降低網損。Then reactive power optimizing calculation is figured out on the chongqing power network on condition that the loss minimum of the active power network is object function, taking account of the limit of voltage restriction condition, adopting three mode of generators adjustment reactive power compensation and tap change. it achieves satisfaction result, expectable purposes of reducing voltage and active loss
然後以系統有功網損最小為目標,考慮電壓約束條件的限制,採用發電機調節、無功補償、分接頭調整三種調控方式對重慶電網低谷時段的運行方式進行了無功優化計算和分析,取得了滿意的結果,達到了預期的降壓目的,減少了網損。This study have investigated optimal reactive compensation for daqing power distribution network. the job include the following aspect : thoroughly analyze the power distribution network of different level voltage and the manner of the power reactive compensation, aim at the question of the distribution network in reducing wasting and increasing voltage quality, put forward some feasible solving method
論文針對電網無功優化研究面臨的主要難點,對大慶城市配電網無功優化補償進行了研究,所做工作主要包括以下幾部分: 1 )對大慶不同電壓等級的城市配電網、無功補償方式和無功補償裝置進行了深入分析,針對城市配電網在降低損耗、提高電壓質量等方面存在的問題,提出了切實可行的解決方法。Tal series high exchange filter installation, 6 - 35kv exchange mainly for electricity grid, as scheduled filter out the high harmonics currents, reducing grid voltage sinusoidal wave distortions rate, while providing compatibility for mouttalos no credit, improve the power factor lines, lowering the depletion, save energy, clean grid
的電力交流電網中,作為濾除預定的高次諧波電流,降低電網電壓正弦波畸變率,同時為基波提供容性無功提高線路的功率因數達到降低損耗節約電能凈化電網的目的。In the power transmission system, reactive capacity and active power is closely related to each other, at feeding power load required active power and reactive capacity. if a mount of reactive capacity could be supplied by far location but no local station, a great deal of reactive capacity and active power would be wasted, and its voltage be descended
在電力傳輸系統中,無功功率和有功功率是密切相關的,在輸送電力負荷所需要有功功率的同時必須消耗一定量的無功功率,同時輸送無功電力也需要消耗有功功率。如果大量的無功電力不能就地供應,靠長途輸運,就會產生較大的無功和有功損耗及電壓降落。This article has discussed the control problem in a distribution substation and on the distribution line respectively. reactive power / voltage control in a substation using general approach usually results in the voltage of the second side being too close to the boundary. it will make the ability of enduring the variation of load in a system decrease a lot and become the threat of the system
本文分別對配電系統中的變電站及配電線路的無功電壓優化控制問題進行了研究,採用常規方法進行變電站電壓無功控制時,往往使二次側電壓過于接近邊界而導致系統承受負荷波動的能力大大下降,成為系統安全運行的隱患。分享友人