  1. This article aims at the boiler ' s problems in operation : 1 ) under nominal load, the smoke temperature at the outlet of hearth reaches 1200, far more exceeds 1050 the original designed temperature. this will always result in slag inside boiler and the temperature of overheater ' s pipe superheat, so that boiler cannot take nominal load and all these influence boiler ' s nomal operation heavily, 2 ) this article also studied the reason why the assistant oil becoming necessary when coal changes. during the nomal operation, many factors ( makeup of combustor and its disposal, smirch and encrust of water wall, excessive air coefficient, temperature of primary air, coal type and density of coal dust ) can deviate the designed working conditions, then affect the boiler ' s nomal operation

    本文針對該爐在實際運行中存在的問題:在額定負荷下,爐膛出口超溫、低溫段過熱器前煙溫高達936 ,遠遠超過815的設計值;噴燃器四周水冷壁焦嚴重,過熱器管壁溫度超標,無帶上額定負荷;甚至有時因燃煤質量的變化,必須投油助燃的嚴重情況進行了分析研究。在實際生產過程中,燃器的構、布置,水冷壁的粘污、垢,過剩空氣系數、一次風溫、煤種及其濃度變化等許多因素都會偏離爐的設計工況,從而影響爐內的傳熱和燃,造成爐膛出口超溫、水冷壁渣等問題。
  2. In this thesis, the measuring methods of main combustion parameters of coal burning boiler are analyzed and compared on the basis of the conclusion of relative experiences of both here and abroad. and by integrating relative knowledge of the combustion regulation of coal burning boiler, a set of the on - line monitoring system of the combustion condition of boiler is designed and developed, which is used to measure the important parameters of the burning process of boiler exactly, and is suitable to the tangentially fired furnace boiler

    在總國內外相關經驗的基礎上,本文分析比較了火電廠燃煤爐主要燃參數的測量方,並合燃煤爐燃調整的有關知識,設計開發了一套爐燃在線監測系統,用於對爐燃過程的重要參數進行實時準確的測量,適用於中間儲倉式、熱風送粉的四角噴燃爐。
  3. The reform scheme of no. 1 boiler in fengtai company is confirmed on the basis of cold / hot tests, theoretical discussions and calculations. in the process of field retrofit, it is indicated in the operation of the improved furnace that without the change of furnace structure, the transform of the burner angle has shrunk the tangential diameter and prevented flames burning on furnace walls, and the burning state of furnace has been bettered, simultaneously, lowering the slagging wi in furnace, thus laying sol id foundation for the safe and economic operation of generating units. wuyanrong ( power plant thermal power engineering ) directed by prof

    本論文通過冷、熱態試驗,經過論證和計算,確定了豐泰公司~ # 1爐燃器的改造方案,並進行了現場改造,改造后實際運行狀況表明:在無改變爐膛構的情況下,改變燃器角度,縮小切圓直徑,使火焰不貼壁,改善了爐內燃工況,同時降低了渣的程度,為機組的安全經濟運行奠定了必要的技術基礎。
  4. The performance testing method is suggested for the boiler using mixed fuel of oil and touch gas

    摘要介紹了燃油爐摻火炬氣后的性能試驗方果。
  5. In this thesis, designing " a " furnace arch by applying momentum synthesis and applying the laminar coal supply device to improve the burning in furnace, the operation duty of chain boiler, the thermal efficiency of boiler, are studied, according to the problems of the irrationality on boiler proper frame and the disproportion on system disposition in the design and the operation of chain boiler

    本文根據鏈條爐設計和運行中存在爐本體構上的不合理、系統布置上的不匹配等問題,研究了利用動量合成設計「 」型火焰爐拱,以及利用分層給煤裝置來強化爐內燃,改善鏈條爐運行工況,提高爐熱效率。
  6. The research objective is to improve the control system performance through the combination of the advanced control strategy with the meaningful information mined from the history operation database. firstly, a new solution for the control performance enhancement is presented by the reference of the kdd technology. aiming at practical application, a novel boiler load control method, which combines the multiple model adaptive control strategy with the data mining technology, is put forward in this dissertation

    本文第一部分為熱工過程式控制制與數據信息採掘,研究的重點是通過先進控制策略的應用以及運行數據中發掘的有用信息,提高現有典型熱工過程式控制制系統的性能,內容包括:首次提出了借鑒數據信息採掘技術的思路和方,用於完善現有的熱力系統優化控制方案;在此基礎上合生產實際,提出了運用多模型自適應策略實施爐負荷控制,並利用關聯規則的數據信息採掘方,通過對燃料發熱量信息的在線診斷,優化控制器構,同時實現爐燃配風的自適應調整,提高負荷、燃控制系統性能。
  7. The thesis also makes a study of the combustion optimization of boiler at the part load condition through testing, and draws some useful conclusions

    對電站爐低負荷運行(深度調峰)時的燃優化問題,也通過試驗的方進行了研究,得出一些有用的論。