相敏檢測器 的英文怎麼說
中文拼音 [xiāngmǐnjiǎncèqì]
相敏檢測器
英文
phase sensitive detector- 相 : 相Ⅰ名詞1 (相貌; 外貌) looks; appearance 2 (坐、立等的姿態) bearing; posture 3 [物理學] (相位...
- 敏 : Ⅰ形容詞(靈敏;敏捷) quick; agile; smart; nimble Ⅱ名詞(姓氏) a surname
- 檢 : Ⅰ動詞1 (查) check up; inspect; examine 2 (約束; 檢點) restrain oneself; be careful in one s c...
- 測 : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
- 器 : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
- 檢測器 : detector
- 檢測 : check; detection; test; gauging; detecting; sensing; [工業] checkout; measuring
-
Intrusion detection can monitor and analyze the behavior of users and system, audit the system configuration and holes, assess the integrality of data and sensitive system, recognize attack action, stat and audit the abnormal behavior, collect the patch related with system automatically, and record the hacker ' s action uses honey pot. intrusion detection helps system administrator monitor, audit and assess the system state easily and available
入侵檢測具有監視分析用戶和系統的行為、審計系統配置和漏洞、評估敏感系統和數據的完整性、識別攻擊行為、對異常行為進行統計和審計、自動地收集和系統相關的補丁、使用誘騙服務器記錄黑客行為等功能,使系統管理員可以較有效地監視、審計、評估自己的系統。This compound was firstly used as a fluorescence carrier of chemical sensors to examine the toxic p - nitroaniline. compared with conventional methods, this sensor has lower cost, wider detection range, higher sensitivity and selectivity, better reproducibility and reversibility. 4
與傳統的檢測對硝基苯胺的方法相比,該傳感器操作簡便,製作成本低廉,在較寬的范圍內有響應,具有較高的靈敏度和選擇性,重現性好,響應迅速。In the thesis, a signal processing scheme of polarization - insensitive fiber optic michelson interferometric magnetic sensor is described : making the interferometer work near the quadrature with closed loop controlling working point method, the fundamental frequency component of the magnetic field sensing signals can be detected to measure the input direct current ( dc ) magnetic field by phase sensitive demodulation
本文主要介紹了偏振無關光纖michelson干涉型微弱磁場傳感器信號處理的方案:通過閉環控制工作點演算法使干涉儀工作在正交工作點處,再利用相敏檢波演算法提取傳感器輸出信號的基頻分量,以測量直流磁場的大小。Although this method gives high sensitivity, the radioactive labels present many problems such as a potential hazard to analyst and environment, which limited its application in dna diagnostic laboratories. in order to overcome these problems a serious of non - radioactive dna probes such as fluorescent, chemiluminescent and electrochemical probes have been developed. although these new methods display many advantages, they have not been used to take place completely the traditional method because of low sensitivity or complex equipment or other shortcomings
自20世紀80年代以來,各種非同位素如酶、熒光素、生物素、地高辛標記的化學發光法和熒光分析法以及以電活性物質做標記的電化學方法相繼問世,這些方法雖然在一定程度上克服了同位素標記的缺陷,但由於存在靈敏度不夠高或檢測系統龐雜或儀器價格昂貴或標記物不穩定等缺陷,還不能完全取代傳統方法。Except for types of stationary phase, components of mobile phase and types of detectors, other prescribed conditions under each type, such as internal radius and length of chromatographic column, brand of stationary phase, carrier granularity, flow speed of mobile phase, as well as proportion, column temperature, volume of incoming samples of different components of mixed mobile phase and sensitivity of detector can be appropriately changed to accommodate different chromatographic system and reach requirements for applicable test of the system
各品種項下規定的條件除固定相種類、流動相組成、檢測器類型不得任意改變外,其餘如色譜柱內徑、長度、固定相牌號、載體粒度、流動相流速、混合流動相各組成的比例、柱溫、迸樣量、檢測器的靈敏度等,均可適當改變,以適應具體的色譜系統並達到系統適用性試驗的要求。Research of digital phase signal detecting in remote field eddy current detecting
遠場渦流檢測中的數字相敏檢波器的研究The design and application of the measuring circuit of inductance sensor base on the soft digital phase sensitivity detection
基於軟相敏檢波演算法的電感傳感器測量電路的設計Experiment indicates that the sensor has a series of virtues, such as high sensitivity to aldehyde, good selectivity and reappearance, very short response time and stable performance, compared with ib processed before, it is easier to regenerate and has much longer lifetime
該qcm傳感器,在液相中都表現出了對甲酸良好的響應敏感特性,在線性度、靈敏度、穩定性與重現性等方面均優良。有望用於對甲酸的在線檢測。The purpose of this paper is to resolve some key technologies of the amplitude - modulation inductive displacement transducer signal processing circuit with nanometer resolution, such as the design of high stability signal generating circuit ; the technology of high precision digital phase - sensitive detection circuit ; the technology of digital filter and linearization, etc
本文主要研究調幅式電感位移傳感器精密測量系統中涉及的高精度載波信號發生技術、高精度數字相敏檢波技術、數字濾波及線性擬和等關鍵技術,目的是進一步改善調幅式電感位移傳感器精密測量系統的測量精度,適應納米級測量的要求。The article relates that the tool ' s measurement precision has been improved by applying cycling acquisition method, self calibration function and phase - sensitive detector. the image coverage rate is improved and reached to 60 percent by increasing the number of pad ' s buttons. the tool carried out two logging functions : fast - scanner mode and dip mode
本文敘述了採用循環採集法、自刻度功能、相敏檢波等方法提高了儀器的測量精度;通過增加極板電扣的數量將圖像覆蓋率提高到60 ;實現了快掃描、傾角兩種測井模式;將測斜短節與預處理短節合二為一,縮短了儀器長度;去除了零伺服控制系統,簡化了電路;用fpga晶元對採集控制器重新設計。In this article, the method of pgc302 ( fid detector ) process gas chromatograph on measuring of hydrocarbons in air separation plant is introduced
摘要介紹了用pgc302氣相工業色譜儀( fid檢測器)直接測定空分裝置液態氧中碳氫化合物的分析方法,該方法具有自動化程度高,靈敏度精密度好等優點。The impact of makeup gas for packed column on sensitivity of fid ( flame ionization detector ) was studied with different concentration sample and different carrier gas flow in order to find out optimal sensitivity of gas chromatogram
摘要本文研究氣相色譜填充柱在不同柱流量和不同濃度的苯系物樣品,使用尾吹氣對fid檢測器靈敏度的影響,以確定分析儀器的最佳靈敏度。It is necessary to establish a new system for steering performance evaluation of electric power steering. this paper analyzes the effect of electric power steering on the steering performance based on it s configuration feature and then the object evaluation of steering performance of electric power steering is studied. the new system of evaluation includes steering maneuvrability, steering returnability, once enter handling performance, steering wheel vibration, servomotion sensitivity and assist characteristic
電動助力轉向是轉向系統中較新的技術,在國內發展很快,關于其性能和可靠性檢測還未有統一的方法及評價標準,本文研究的目的主要是對針對電動助力轉向的結構特點,分析了電動助力轉向對汽車轉向性能的影響,提出從轉向輕便性、轉向回正性、轉向盤中間位置區域性能、轉向盤振動、隨動靈敏度和助力特性等方面進行電動助力轉向系統轉向性能的客觀評價,並探討了相應的評價指標,以及對電動轉向系統的電機減速機構及其控制器、傳感器、提出相應的技術要求與試驗方法。Compared with d - shaped fiber, the d - shaped fiber bragg grating index sensor is more precise and reliable because the sensed information is encoded into wavelength, which is an absolute parameter, the output does not depend on the light levels, loss in the connecting fibers and couplers, or source power
光纖布喇格光柵傳感器以波長偏移和功率變化同時作為傳感度量,由於波長檢測對光功率漲落不敏感,相對于只以功率變化作為傳感度量的傳感器件,具有更高的傳感精度和準確性。In the experiments, the polypyrrole gas sensor was prepared on screen - printed electrodes by cvd ( chemical vapor deposition ). the effect of the electrochemistry undoping and doping on the characteristic of the gas sensor was studied
實驗採用化學氣相沉積的方式在絲網印刷電極上沉積聚吡咯氣敏膜用於氣體的檢測,並研究了電化學去摻雜?摻雜對傳感器氣敏特性的影響。So, mfld provides a new way to obtain optical information for optical chemo - and biosensors. compared with conventional detection methods, in which the detector was placed at the distal end of the fiber, mfld has advantages in much higher singnal - to : noise ( s / n ) ratio and sensitivity, since the analyte signal is measured against a much lower background by placing the detector at the fiber - optic profile instead of the distal end
模式濾光檢測和傳統的檢測方式相比,檢測器的位置由光纖末端改放在光纖側面,獲取光纖側面產生的模式濾光信號,由於光纖側面的背景光遠較光纖末端的出射光背景小,因而較之檢測光纖末端的出射光有高得多的信噪比和靈敏度。The card has been applied in our single photon counter cell function analyzer for automatic detection. this analyzer can detect the ultra - weak luminescence sensitively and comparably
此採集卡應用於超微弱發光單光子計數細胞功能分析儀,實現了相關檢測的全程自動化測量,該儀器能夠靈敏、直接並有對照性地檢測超微弱化學發光。It is also applied to determine hepatitis b surface antigen using the sensor chip inunobilized with anti - hbsag monoclonal anibody. to compare with spr method, the same hbsag solotions are determined using the method of enzyme - linked immuosorbent assay ( ellsa ). the kinatics of inununo - reaction is studied using the spr sensol in the second task, the theory of the sensing technology is investigated
實驗結果表明: spr傳感器具有良燈的重現性,其靈敏度為1844iun riu ,對折射率的分辨能力為5xio 」 aiu ; x利用該spr傳感器測定了兩種葡萄糖注射液,將檢測結果與藥典法中所採用的標準方法進行了對比,實驗結果表明了兩種方法的相對誤差分別為1刀5和1分享友人