瞬時響應數據 的英文怎麼說

中文拼音 [shùnshíxiǎngyīngshǔ]
瞬時響應數據 英文
transient response data
  • : Ⅰ名詞(眼珠一動; 一眨眼) wink; twinkling Ⅱ動詞(眨眼) wink
  • : shí]Ⅰ名1 (比較長的一段時間)time; times; days:當時at that time; in those days; 古時 ancient tim...
  • : 應動詞1 (回答) answer; respond to; echo 2 (滿足要求) comply with; grant 3 (順應; 適應) suit...
  • : 數副詞(屢次) frequently; repeatedly
  • : 據Ⅰ動詞1 (占據) occupy; seize 2 (憑借; 依靠) rely on; depend on Ⅱ介詞(按照; 依據) according...
  • 數據 : data; record; information
  1. The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,

    基於基爾霍夫定律的電流差動保護無論對於何種形式的輸電線路都是一種簡單、可靠、選擇性強的保護形式,電力系統的發展使得電流差動保護用於線路保護成為需要,而電子、通信技術的發展使得電流差動保護用於輸電線路成為可能。首先,本文對目前線路保護的研究和實際用情況進行了討論和分析,比較了常用線路縱聯保護的實現原理和實現條件及優缺點。其次,針對常規相量電流差動保護易受正常負荷電流和故障過渡電阻影的缺點,同為加快差動保護的動作速度,對基於故障分量采樣值電流差動保護的原理、判、動作特性等作了討論和分析,結果表明基於故障分量采樣值電流差動保護在可靠性、靈敏度、抗電流互感器飽和方面明顯優于常規相量電流差動保護,對電流差動保護各端的同步采樣方法和通信也進行了分析和評價。
  2. In order to improve the prospecting precision to the earth of transient electromagnetic method ( tem ), the idea of tem imaging is proposed according to the characteristics of both electromagnetic wave propagation and response : the wave - impedance is calculated from observed data in - field by the way of inverse - faltung and linear digital filter ; the sequence of reflection coefficients corresponding to every tiny - lever move time is calculated by the way of linear programming, and the imaging result section is drawn consequently

    摘要?提高變電磁法的對地探測精度,從變電磁場的傳播特性和電磁特性兩個角度?慮,提出了變電磁成像方法:由野外實測磁場感,經過反褶積和線性字濾波求出波阻抗;用線性規劃法求出每一微層走所對的反射系序列,並以此?參繪製成像結果圖。
  3. Firstly, wall ’ s transfer matrix is deduced by laplace transformation based on 3r2c thermal network model. secondly, frequency response of transfer matrix is calculated. thirdly, we make the frequency response of transfer matrix of stimulation model equate the theoretical frequency response of wall transient heat conduction by applying appropriate identification algorithm, from which we can obtain every polynomial ’ s coefficient of model transfer function, then each parameter of resistance and capacitance is calculated by appropriate optimization algorithm

    首先,根模擬熱流網路模型用拉普拉斯變換推出墻體的傳遞矩陣;然後,計算傳遞矩陣的頻率;最後,採用頻域回歸方法求出模型傳遞函各次項的系,進而通過一定的優化演算法確定模型的各個熱阻、熱容參,使通過模型建立的多項式s -傳遞函與墻體傳熱的理論超越s -傳遞函完全等價。
分享友人