確動 的英文怎麼說

中文拼音 [quèdòng]
確動 英文
positive motion
  • : 形容詞1. (符合事實; 真實) true; reliable; authentic 2. (堅固; 堅定) firm
  1. The crankshaft checked in dynamic equilibrium ensures the enggine running smothly

    經過精確動平衡的曲軸,使柴油機運行平穩。
  2. Are vivariums / cages labelled correctly, identifying the animal, it ' s statistics and brief requirements

    物飼養場地/獸?標示是否正物的辨? 、 ? ?統計和各種物的需求標示是否明
  3. It is designed for a power plant in order to reduce the workload of the relay protection workers, decrease the percentage of protection device ' s false action, and increase the work efficiency of the device in power plants

    可視化的發電廠保護整定綜合系統是為減輕發電廠繼電保護工作人員的勞強度,降低保護設備的不正確動作率,提高發電廠設備的運行效率而開發。
  4. Through analyzing the two cases of protection malfunction due to incorrect connection of open - delta connection of busbar voltage transformer, the importance of correct connection of open - delta connection when earthing fault occurring in a power system was explained

    摘要通過分析兩起母線電壓互感器開口三角形接線錯誤引起的保護不正確動作,從而說明在系統發生接地故障時電壓互感器開口三角形接線正的重要性。
  5. If corresponding information of cad drawing is linked to external database and electric intellectual files of users is constructed, we can make use of the bridge ( model block or programmes ) between autocad and database to display and control change of drawing and database flexibly, correctly, dynamically and comcidentally

    如果將cad圖中的有關信息鏈接到外部數據庫中並建立用戶電子智能文檔,就可以利用autocad與數據庫之間的橋梁(模塊或程序)來靈活、準態而一致地顯示及控制圖形和數據庫的變化。
  6. At the same time, we have discovered some bug in cooperate between the two type protection, analyzed different result in different condition as config with different logic protection, show that the incorrect relay act result from these bug only appear when line is in incompletely phase operation and occur fault, furthermore the mass computer protection have comprehensive incompletely phase logic, so this condition can not seriously threaten the power system

    同時,也發現了兩種保護裝置在配合上存在一些缺陷,分析了這種邏輯上的不配合在不同情況下所造成的不同後果,並且指出由於這些缺陷所造成的保護裝置不正確動作的情況僅在線路非全相運行時又故障的情況下才可能出現,而且現有的成套微機保護的都具有較為完善的非全相邏輯,在保護裝置正常投運的情況下,還不致對系統安全構成重大隱患。
  7. All simulation and digital signal conveying between machine and cabinet is right reliable, and compliance with design

    各機櫃間所有模擬、數字(報警聯鎖)信號傳遞正作可靠,符合設計要求。
  8. Along with the development of power system, more and more generators and ehv transmission systems are put into operation. there come many new situations, such as the lengthening transmission distance, the heavier load, the increasing transient elements during the transient process. these new conditions influence the correct working of relay protections

    隨著電力系統的不斷發展,大容量發電機組和超高壓輸電系統的相繼投入運行,系統中出現了許多新的情況,如輸電距離增大、負荷加重、故障暫態過程中的暫態分量大大增加、持續時間變長等,這些情況對目前常用的各種繼電保護方法的正確動作會產生許多不利的影響,甚至不能正常運行。
  9. The misoperation of high frequency protection caused by the electromagnetic disturbance was analyzed and the bad anti - jamming ability of existing coaxial - cable which is an important reason of misoperation in high frequency protection was pointed out

    摘要對電網高頻保護通道受電磁干擾發生不正確動作現象進行了分析,指出現有同軸電纜抗干擾性能差是高頻保護不正確動作的重要原因。
  10. Agent protection can prevent the maloperation and accelerate the backup protection. the maloperation of this protection is not a common phenomenon

    大型電站agent保護對于保護整體性能的提高主要體現在防止保護的不正確動作和加快后備保護的作速度。
  11. All the keyboard events will be propagated to the xim, which determines the appropriate action for the events based on the current state of the xic, and passes back the resulting characters

    所有鍵盤時間都被傳遞到xim ,它根據xic的當前狀態決定事件對應的正確動作,然後傳送回相應的字元。
  12. The experimental result of the system has shown that the correct performance rate of relay protection is 100 %, the performance of safety automation equipment is normal, and the communication system satisfied the demand of data transmission

    製作的樣機實驗結果表明繼電保護正確動作率百分之百,安全自裝置功能運行正常,通信系統滿足數據傳輸的要求。
  13. If we can locate the fault section rapidly and accurately when fault occuring, we can isolate the faulut area, resume the power supply for the unaffected area, decrease the power cutted area and bring out great economic benefits

    當配電網饋線發生故障時,要是能夠迅速、準定故障區域,就能正確動作相關的電氣設備來隔離故障區域,恢復對非故障區域的供電,減少停電面積,帶來巨大的經濟效益。
  14. For current misoperation cause of microcomputer relay protection, the paper introduces the technology of scattered arrangement protection to improve anti - inteferance ability, the usage of computer digital communication technology to enhance fault diagnostic function of micro computer protection device and outside circuit and decrease bad contact of contactor and terminal which may cause ralay misoperation, establishment of electrical protection remote management network to realize maintenance under condition

    針對目前微機保護不正確動作的原因,提出了採用保護分散布置技術,提高抗干擾能力;應用計算機數字通信技術,增強微機保護裝置及外聯迴路的故障診斷功能及減少接點和端子接觸不良引起的保護不正確動作因素;建立電網保護管理遠程網路,實現「狀態維修」 。
  15. For existed statistics method shortcoming of " relay correct operating rate " which is used by electric power system of our country for a long time, the paper provides a new statistics and calculation method which will give important direction to relay protection design, manufacture and operation administration in our country

    摘要針對我國電力系統長期沿用的「繼電保護正確動作率」統計方法存在的缺點,提出了新的統計和計算方法,對提高我國繼電保護的設計、製造及運行管理具有重大的指導作用。
  16. Precision power transmission, double - pitch power transmission, and double - pitch conveyor roller chains, attachments, and sprockets

    確動力傳送雙齒節力傳送和雙齒節輸送帶滾子機鏈附件和供片輪
  17. The cam - follower is the main mechanism of the engine that carries out a series of accurate motions. its mild wear may gradually worsen the contact conditions. the probability for surface fatigue will then increase due to changes in the surface topography

    凸輪?挺柱是內燃機中實現一系列精確動作的主要機構,其磨損會使接觸條件惡化,由此產生的表面形貌的變化會使表面疲勞的概率增加,可能會對部件產生破壞性的影響,進行凸輪機構的摩擦學設計對提高內燃機的運行性能和延長使用壽命十分重要。
  18. In reality, he had indeed experienced these procedures ? years before ? and unlike his brain operation, they had successful outcomes

    在現實世界中,他的確動過這些手術,但那是幾年前的事,而且不像這次的腦部手術,那些手術是成功的。
  19. At the same time it has an important significance to study roundly the structure of boom system of the truck - mounted concrete pump. based on the certain boom system model of the truck - mounted concrete pump made in china, the primary content of this thesis includes two aspect of boom system of the truck - mounted concrete pump. one is the dynamics simulink of boom system based on flexible multi - body and stress of boom structure based on the result of dynamics simulation of boom system

    論文在綜述國內外混凝土泵車發展概況和技術水平的基礎上,說明了臂架系統的研究現狀及本論文所基於的方法,並從以下兩個方面對臂架系統進行了研究: 1 .利用pro / e建立了臂架系統的三維模擬模型,利用ansys軟體與adams軟體,對臂架系統的工作過程進行了基於剛柔混合臂架模型的力學模擬,得到了基於精確動力學模擬結果的臂架的應力分析結果。
  20. And modern movement of relay protection time more and more little, smaller than 20 ms generally, accurate working voltage of movement its low to 1 - 3 vs

    而現代繼電保護的作時間越來越小,一般小於20ms ,其準確動作的工作電壓低至1 3v 。
分享友人