空氣比測儀 的英文怎麼說

中文拼音 [kōng]
空氣比測儀 英文
air comparator
  • : 空Ⅰ形容詞(不包含什麼; 裏面沒有東西或沒有內容; 不切實際的) empty; hollow; void Ⅱ名詞1 (天空) s...
  • : Ⅰ名詞1 (氣體) gas 2 (空氣) air 3 (氣息) breath 4 (自然界冷熱陰晴等現象) weather 5 (氣味...
  • : Ⅰ動詞1 (比較; 較量高下、 長短、距離、好壞等) compare; compete; contrast; match; emulate 2 (比...
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : 名詞1 (人的外表) appearance; bearing 2 (禮節; 儀式) ceremony; rite 3 (禮物)present; gift 4 ...
  • 空氣 : 1 (大氣) air; atmosphere 2 (氣氛) atmosphere 3 (氣閘) air brake4 pneum ; pneumo ; pneumat ;...
  1. Using mass flux controller ( mfc ), gas regulation system achieved accurate mix of two kinds of gases, steel bottle gas ( some compressed gas ) and zero air ( pure air ). for the sake of data transmission between dynamic air regulator and other equipments in the monitoring air quality system, normal digital interface ( rs - 232c ) make correlative role of communication interface so that automatic survey could be achieved

    器採用國際先進的自動控制配原理,採用精密質量流量控制器( mfc )來控制鋼瓶(某種壓縮體)與零(純凈無污染的)的混合來得到精確濃度的校準體,以便於對各種體監進行高精度校準。
  2. Methods of calibration for exposure meters, air kerma meters, air absorbed dose meters and dose - equivalent meters

    曝光計釋動能吸收劑量和劑量當量的校正方法
  3. To overcome this problem, not only the meteorological observation network has to be equipped with automated, higher precision, and more economical devices and instruments, but also a synthetic mobile observation system is required for filling in the data gaps between the surface and upper air sounding stations

    為了克服這一問題,除了研製自動化程度高、量精度高和性能價格高的器設備來裝備現有的定點大網外,還應建設一些流動的大系統,以獲得常規大臺站檔間(如大洋、山區和荒漠等無人區)的天現象和大環境變化的信息。
  4. In this work, according to the feature of soft x - ray fluorescence, a setup has been established for the measurement of soft x - ray fluorescence in laboratory, which is calibrated by 55fe. the setup is made of x - ray tube, fine tuning table, vacuum system, gas - flow proportional counter and multiple channel analysis

    本文工作中依據軟x射線熒光的特點,在實驗室建立了一套軟x射線熒光量裝置,該裝置由x射線管、精密微調樣品臺、真系統和流計數管探系統以及多道分析組成,並採用~ ( 55 ) fe標準光源對系統進行實際標定。
  5. At the same time the number of holes for liquid flowing, gas flowing and blocked to the number of total holes was defined as liquid flowing ratio, gas flowing ratio and blocked ratio. the experiment was made with in - diameter 500mm column using water - air system, the ratio was first delected in detail by multi - path conductivity gauge for the compound tray with free area 20 % and 25 % respectively

    採用多路電導,在直徑500mm的冷模塔內,以-水為介質,首次較系統地量了開孔率為20和25的復合塔板的通、通液和阻塞篩孔的數量例,獲得了通率、通液率和阻塞率隨液變化的基本規律。
  6. To calibrate a dew - point hygrometer, a stream of low flow rate air, generated by a standard humidity generator and at the specified dew - point temperature, is passed through both the uut and reference dew - point hygrometers which are then compared

    由標準濕度產生器產生的低流速定值露點溫度的會流經被器及參考露點濕度計,然後互相對,從而校正露點濕度計。
  7. The measure of ellipsometer shows : the refractive index value of c60 cluster films in gas atmosphere is smaller than that of vacuum c60 films ( our measurement result is 1. 94 ) and refractive index value of c60 cluster films in ar is larger than that in n2. both refractive index values are nearly the same in lower pressure ( about 1. 46 ), but decrease with increasing gas pressure

    橢偏量表明:氛條件下制備的c60薄膜的折射率n在真條件下制備的c60薄膜的折射率( 1 . 94 )小;在低壓強條件下,不同氛中制備的樣品的折射率也幾乎相等;在一定的壓強范圍內,折射率隨著壓強的增大而減小。
  8. Experiments have demonstrated that, under the condition of constant temperature ( 20 ), the frequency error of double - frequency laser interferometer with two longitudinal modes could be controlled within 10 " 9 even with conditions such as with cool or hot air blowing, it can still be kept within 10 " 7. self - organised fuzzy control methods can be realised in a single - chip processor which contains fuzzy optimisation and self - organisation functions. the above - mentioned system possesses the following advantages : simple

    / znl (式中c為光速, l為諧振腔長, n為折射率,其值約790mhz ) ,原理上對目前可能要求的量速度都能滿足;它發出的光為一對互相垂直的線偏振光,與塞曼型雙頻激光干涉,它不用外加軸向磁場及1 / 4波片,因此結構簡單,造價低廉。
分享友人