keep-alive voltage-
The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance
爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。The two - dimensional axisymmetric subsonic - transonic - supersonic flow in an experimental arcjet thruster is simulated numerically using flux vector splitting method. the profiles of density, velocity, temperature, pressure and mach number can be obtained by the computation. the computation grid and some computed results are given here. the test equipment such as power supply system, ignition system, propellant supply system, arcjet thruster, thrust measuring device and vacuum system are introduced briefly. some working phenomena of the arcjet are observed and discussed. three different kinds of instability appeared in the process of the experiments. except some important parameters are measured, it is found that the operating stability of argon is better than that of nitrogen
對一實驗電弧加熱式發動機二維軸對稱亞跨超音速流動進行了數值模擬,所採用的方法是矢通量分裂演算法.通過計算可以得出密度、速度、溫度、壓力和馬赫數的分佈.給出了計算所使用的網格和一些計算結果.簡要介紹了實驗所使用的設備,如電源系統、點火系統、推進劑供給系統、電弧加熱式發動機、推力測量裝置和真空系統.對所觀察到的一些工作現象進行了討論.有三種不同的不穩定性出現于實驗過程.除了所測量的一些重要參數,通過實驗發現氬比氮工作更穩定
分享友人