線束準直器 的英文怎麼說

中文拼音 [xiànshùzhǔnzhí]
線束準直器 英文
beam collinmator
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : Ⅰ動詞1 (捆; 系) bind; tie 2 (控制; 約束)control; restrain Ⅱ量詞(用於捆在一起的東西) bundle;...
  • : Ⅰ名詞1 (標準) standard; guideline; criterion; norm 2 (目標) aim; target Ⅱ動詞1 (依據; 依照)...
  • : Ⅰ形容詞1 (成直線的; 硬挺的) straight; stiff 2 (跟地面垂直的; 從上到下的; 從前到后的) erect; v...
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  1. The position and size of the monochromator, focusing curvature radii and tilting angles of the germanium focusing monochromator under different different take - off angle, size and divergency of the second collimator and intensity loss due to the use of it were determined. the neutron flux at different wavelength, under different reflection and take - off angle of the monochromator and divergency of the first collimator, were given. the simulation on the aperture used for limiting beam size in front of the sample showed that, smaller the size of the aperture and further the distance from the aperture to the sample, greater the loss of the intensity and more serious the spread of the beam along vertical direction at the sample position which makes the practical sampling volume greater than expected

    用蒙特卡羅模擬方法對中子應力衍射譜儀的設計方案進行了優化研究,提出了一系列可供參考的數據:確定了單色的位置、尺寸、垂聚焦單色在不同起飛角下的聚焦曲率半徑和傾角;討論了第二的尺寸和發散,以及使用第二造成的強度損失;給出了在不同單色反射面、起飛角、中子波長和第一發散度的情況下樣品處的中子注量率,以及多種組合情況下譜儀的解析度曲;對限方孔的尺寸、距離樣品遠近對強度損失和測量中的影響做了深入研究。
  2. At first, the author analyzed some chief factors such as light beam drift and atmospheric turbulence that affect the precision of the laser collimation in brief. then, the author studied the plan of the laser collimation generating nondiffracting beam and automatic level system with high precision. at last, the author completed the measurement of the straightness guideway by using ccd ( charge coupled device ) as the receiver and computer imaging processing

    文章首先簡要地分析了激光自身漂移、大氣湍流等影響激光精度的主要因素,然後對系統的激光方案進行論證,並確定了無衍射光的生成方案、高精度自動安平系統的結構方案,最後以ccd為接收件,通過計算機圖像處理,完成對軌道性的測量。
  3. X - ray beam collimator x

    線束準直器
  4. The methods of straightness measurement are mostly about a line, but the straightness of couple lasers is the mainly problem in the system. first the couple laser beams should be calibrated separately. then, the couple laser beams should be aligned, and it is the most important problem in the design

    現在度的測量方法多數是對一條度進行測量,本文所要解決的主要問題是兩激光的性校,首先要分別對兩激光性校,然後將兩激光調到一條上,這也是設計中的重點問題。
分享友人