繼電保護運行 的英文怎麼說
中文拼音 [jìdiànbǎohùyùnháng]
繼電保護運行
英文
principles of relay protection- 繼 : Ⅰ動詞(繼續; 接續; 接著) continue; succeed; follow Ⅱ副詞(繼而) then; afterwards
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 保 : Ⅰ動詞1 (保衛; 保護) defend; protect 2 (保持) keep; preserve; maintain in good condition 3 (...
- 護 : 動詞1. (保護; 保衛) protect; guard; shield 2. (袒護;包庇) be partial to; shield from censure
- 運 : Ⅰ動詞1 (物體位置不斷變化) move; revolve 2 (搬運; 運輸) carry; transport 3 (運用) use; wield...
- 行 : 行Ⅰ名詞1 (行列) line; row 2 (排行) seniority among brothers and sisters:你行幾? 我行三。where...
- 運行 : move; be in motion; run; working; machine run; operation; corotation; propulsion (影片)
-
These character based on sichuan power network ' s practice operation experience, in allusion to the config of the carrier wave protection in bypass breaker operating, through the study of protection ' s typical config : one side lfp - 902a, one side csl - 101a, proceeded comprehensive act module test, noted plenty of first hand test data and wave picture, proceeded detailed theory analyses, plenitude demonstration atresic type carrier wave distance protection when twain side atresic type logic is not completely same, basically can fill power network ' s requirement to relay of reliability selectivity speedly and sensitively
本文結合四川電網的實際運行經驗,針對旁路開關代路運行時的保護配置情況,通過對旁路代路時保護典型配對組合:一側lfp - 902a ,一側csl - 101a的保護配置情況的深入研究,做了全面的動模試驗,記錄了大量的第一手試驗數據和波形,進行了詳細的原理分析,充分驗證了高頻閉鎖式距離零序保護在兩側閉鎖式邏輯不盡一致的情況下,基本能夠滿足電網對繼電保護的可靠性、選擇性、快速性以及靈敏性的要求。It is designed for a power plant in order to reduce the workload of the relay protection workers, decrease the percentage of protection device ' s false action, and increase the work efficiency of the device in power plants
可視化的發電廠保護整定綜合系統是為減輕發電廠繼電保護工作人員的勞動強度,降低保護設備的不正確動作率,提高發電廠設備的運行效率而開發。A large amount of experience data accumulated through long term operation is introduced. combined with the definition of relative requirements, the choosing and definition of operation index of high - frequency channels specially used for protection of hubei electric power network are discussed and elaborated through calculation and analysis such as input impedance and channel impedance of transmitter, sensitive voltage of received signal, redundancy of received signal, warning of channel redundancy and warning of channel faults etc
引用了長期運行中積累的大量經驗數據,通過計算分析,結合有關規程規定,探討和闡述了湖北電網繼電保護專用高頻通道諸如收信機輸入阻抗及通道阻抗、收信靈敏電平、收信裕度、通道裕度告警、通道異常告警等運行指標的選取和確定。Currently. development in this field is still in pioneering exploration in china, management information system of relay protection consists of such modules as equipment management, operation management, statistic analysis, countermeasure and plan management, office management, and technical exchange. to meet the demands from zitong power supply bureau of mianyang electric power bureau
繼電保護信息管理系統,主要由設備管理、運行管理、統計分析,反措與計劃管理,事務管理和技術交流等模塊組成,本文主要以四川省綿陽電力局梓潼供電局的需求提出並以該局變電站為藍本,對這一系統的基本部分進行動態數據訪問開發。Along with the development of power system, more and more generators and ehv transmission systems are put into operation. there come many new situations, such as the lengthening transmission distance, the heavier load, the increasing transient elements during the transient process. these new conditions influence the correct working of relay protections
隨著電力系統的不斷發展,大容量發電機組和超高壓輸電系統的相繼投入運行,系統中出現了許多新的情況,如輸電距離增大、負荷加重、故障暫態過程中的暫態分量大大增加、持續時間變長等,這些情況對目前常用的各種繼電保護方法的正確動作會產生許多不利的影響,甚至不能正常運行。The relay protection ensures the safe operation of the electric system. the relay setting must be selected reasonably in order to exert effect of the relay protection completely
繼電保護裝置是電力系統安全運行的保證。為了充分發揮繼電保護裝置的效能,必須合理地計算選擇各保護的整定值。The experimental result of the system has shown that the correct performance rate of relay protection is 100 %, the performance of safety automation equipment is normal, and the communication system satisfied the demand of data transmission
製作的樣機實驗結果表明繼電保護正確動作率百分之百,安全自動裝置功能運行正常,通信系統滿足數據傳輸的要求。For existed statistics method shortcoming of " relay correct operating rate " which is used by electric power system of our country for a long time, the paper provides a new statistics and calculation method which will give important direction to relay protection design, manufacture and operation administration in our country
摘要針對我國電力系統長期沿用的「繼電保護正確動作率」統計方法存在的缺點,提出了新的統計和計算方法,對提高我國繼電保護的設計、製造及運行管理具有重大的指導作用。Answer : preparative job includes : understands workplace one, the moving circumstance of 2 equipment, this job has with moving equipment without direct connection, have the job that cooperates without need with other team and group ; makes working priority discipline and the blemish that prepare to solve and weak point ; the staff member makes clear to divide the work and be familiar with the concerned data such as blueprint and test gauge cheng ; should be had the blueprint that agrees with actual state, record that examines last, newest rectify spare parts of the instrument that decides requisition, test gauge cheng, qualification, machine parts or tools kept in reserve, tool and join lead to wait ; is a few righter important equipment, especially complex protector or couplet jumps loop protector, should weave test program, working controller should fill in ticket of protection safety precaution, examine and approve via technical chief, just can carry out
答:預備的工作包括:了解工作地點一、二次設備的運行情況,本工作與運行設備有無直接聯系,與其他班組有無需要配合的工作;制定工作重點項目及預備解決的缺陷和薄弱環節;工作人員明確分工並熟悉圖紙與檢驗規程等有關資料;應具備與實際狀況一致的圖紙、上次檢驗的記錄、最新整定通知單、檢驗規程、合格的儀器、備品備件、工具和連接導線等;對一些重要設備,非凡是復雜保護裝置或有聯跳迴路保護裝置,應編制試驗方案,工作負責人應填寫繼電保護安全措施票,並經技術負責人審批,方能實施。This forms a unity of the protective equipment and type selection to power network configuration and setting coordination that ensures the safe and reliable operation of power network extremely. after analyzing the first operation mode of yuncheng power network, the first and the second equipment configuration and operation, this paper sets up a scheme on setting and coordination of yuncheng power network and attention pointing on maintenance, and checks out equipment operation. the scheme reasonably uses the regulation procedures on relaying protection and automatic equipment setting coordination promulgated by china ministry of energy
本文即在對運城電網一次系統運行方式,一、二次設備配置,鐵磁諧振對保護影響分析的基礎上,合理運用部頒《繼電保護及安全自動裝置運行整定規程》 ,兼顧繼電保護的四性要求,制定出運城電網繼電保護整定方案及設備運行維護校驗注意事項,旨在總結鐵磁諧振對保護影響及保護應用過程存在的實際問題和解決方法,尋找區域電網繼電保護安全穩定運行的基石,以提高電網繼電保護安全穩定運行水平。As one of important components of relay protection, automotive reclosing device plays an important role in guaranteeing security, stability and economical running, etc. adaptive single - phase reclosing based on intelligent control is a new sort of protection principle, which develops with the advancement of power system technology and the progress of intelligent control theory
自動重合閘裝置作為電力系統繼電保護裝置的重要組成部分,它在保證系統安全、穩定和經濟運行等方面起著非常重要的作用。智能式自適應單相重合閘是隨著電力技術的進步、智能控制理論的發展,為了滿足對電力系統自動重合閘所提出的更高要求而產生的一種新型的保護技術。Adopt some new material, new technology in design of mutual inductor, apply to mutual inductor to technology of relay protection study
在互感器的設計中採用了一些新材料、新技術,並且對互感器運用於繼電保護的技術進行了研究。Secondly, against different elements influencing branch coefficient, some accelerated measures are described. fast method to calculate branch coefficients without fault calculation is presented
其次,在與繼電保護整定計算密切相關的運行方式的選擇演算法方面,針對影響分支系數的因素,介紹了一些加快措施,提出了無需故障計算的分支系數快速演算法。Code for operating management of microprocessor - based relaying protection equipment
微機繼電保護裝置運行管理規程Evaluation rules of protection equipment and power system stability control devices
電力系統繼電保護及安全自動裝置運行評價規程At last, according to a actual power system relay values calculation case, which is realized on the basis of our theory, the validity and practicability of adaptive calculation and management are proved in practical production and operation of power. index terms : adaptive technology, protective relay setting calculation and management, complex fault, mutiloop network, the coordination of main protection with backup protection
最後,我們結合我們利用本文所介紹的理論實現的一個具體電力系統的定值整定計算和管理的實際例子,驗證了利用自適應技術建立的繼電保護定值計算和管理在實際電力生產和運行中的有效性和實用性。But a series of problem rises with the increasing of wind - generator capacity, the equipments match with the wind - electricity system are becoming more and complex. the serious problem is how to elect the type and disposition of the protection equipnent, for example, relay
但不容忽視的是隨著風電裝機容量的不斷擴大,風電網的配套設備也相應變的越來越復雜,突出的問題是為保證安全運行的繼電保護設備如何選型和配置急待解決。The fault calculation is realized with fault analysis theory of power systems. in the paper, simple fault with operation mode transformation is calculated by modifying node input current. phase - sequence parameter converse technique is used to get general method in calculating complex fault
本文運用成熟的電力系統故障分析理論,實現了繼電保護整定的故障量計算,它採用補償法進行運行方式變化時的簡單故障計算,以求取整定用運行方式,採用故障口相序變換技術實現通用的復雜故障求解,為整定計算奠定了基礎。Relay - protected operation
繼電保護運行Operational and setting code for relay protection of 3 110kv electrical power networks
3 110kv電網繼電保護裝置運行整定規程分享友人