補償電壓 的英文怎麼說

中文拼音 [chángdiàn]
補償電壓 英文
bucking potential
  • : Ⅰ動詞1 (修理; 修補) repair; mend; patch 2 (補充; 補足;填補) fill up; add supplement; supply; ...
  • : 動詞1. (歸還; 抵補) repay; compensate for 2. (滿足) meet; fulfil
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 壓構詞成分。
  • 補償 : compensate; make up; make up for; make it up to sb. ; make sth. good; compensation; offset
  • 電壓 : voltage; electric tension; electric voltage
  1. The electromagnetic unit is composed of medium - voltage transformer, compensation reactor, damper etc., the casing is filled with insulation oil

    磁單元由中器、抗器、阻尼器等器件組成,箱體內充絕緣油。
  2. Exchange non - clearane metal oxidate matter arrester is suitabe for the voltage protection of transformer switch cupboard, vacuum switch etc

    交流無間隙金屬氧化物避雷器,適用於變器、配屏、開關櫃、真空開關、輸線路、力計量箱、並聯容器、旋轉機等保護。
  3. The way of taking one nth out of capacitor ' s the first harmonic capacitive reactance as its nth harmonic impedance is verified whit the data from tang7c. according to the approximately estimating method, the first harmonic impedance of 220kv system is calculated. on the basis of the models, this paper gives the harmonic equivalent circuit of substation and gives the b ( n ) function of the harmonic time n. when the capacitors has different combination, b ( n ) ' s value will also change, with the inputting local measurement data, the paper studies the series and parallel resonance at the substation, and deduces that the reason the capacitor ' s fuse of tang6c is frequently interrupted is that its capacitor current contains a large number of 5th harmonics, and that the reason the discharging pt of tang7c capacitor being exploded is also that the 7th and 9th harmonic currents are amplified

    據此,對該站進行了串聯諧振分析和並聯諧振分析,並結合測試數據和有關變站的運行記錄,指出了導致該站容器湯6c頻繁燒保險的主要原因是5次諧波流含量偏高,引起湯7c放pt爆炸也是因為7次和9次諧波流被放大。針對這些導致湯陰變容器故障的原因,提出了相應的諧波治理措施,包括針對湯6c容器5次諧波流含量偏高的原因,提出了停運湯6c容器或者通過把湯sc容器的部分容量併入湯6c容器(湯sc其餘部分停運)以增加湯6c諧波承受能力的措施;針對# 2變低側7次和9次諧波流被放大的現象,提出了在湯7c容器上加裝一定百分比的串聯抗器的措施。
  4. After which, the battery will be charged by large constant current to allow the fast charging. finally, the constant voltage charging is adopted to guarantee the battery was charged to its full capacity. under the condition that the temperature has raised to a certain threshold at the constant current charging stage, the over temperature circuit is performing and it provides a compensation current which switches the system to constant temperature charging mode with the intention of protecting the ic

    即在充初期採用較小的流對池進行預處理,對出現過放池進行修復和保護;然後採用較大的恆定流對池充,實現快速充的目的;最後採用恆定,確保池充滿;在恆流充階段,當晶元溫度上升到一定程度時,晶元過熱保護路開始工作,該路以提供充流的形式使充進入恆溫充模式,對晶元進行保護。
  5. Second, the results of theory analysis and simulation research show that the output of one cycle controlled bridge switching power amplifier have dc offset because of the nonideal characteristic of reset signal. the magnitude of output dc offset voltage is proportional to width of reset pulse. a voltage compensation technique is used to solve this question, and the computation formula of compensation voltage is gived. the circuit compensated and not are researched through simulation and experiment, which results show that compensated circuit solve the output dc offset effectively

    其次,理論分析和模擬研究結果表明,由於復位脈沖的非理想特性,單周控制的全橋開關功率放大器輸出端存在直流偏置問題,其大小與復位脈沖的寬度成正比。針對輸出直流偏置問題,提出了的改進方案,給出了補償電壓的具體計算公式。對前和后的方案進行了對比模擬研究和實驗研究。
  6. In the part of the transmitter, the pre - amplifier logarithmic amplifier, temperature complement circuit, anti - disturbing circuit, and v / i circuit, are discussed. the transmitter outputs 4 - 20ma. in the part of the displayer hardware design, the i / v convert circuit and the flame intensity signal processing circuit are introduced

    在探頭的設計中,詳細介紹了前置對數放大器路設計,在對數放大器加入了溫度路和抗干擾路,以保證測量精度和較大的量程,最後信號經流的轉換,得到4 - 20ma的標準信號作為探頭的輸出信號,進行遠傳。
  7. With the development of the electric power system, static - state reactive power compensators ca n ' t have met the requirements of the actual production and operation, and the trend to the fast and dynamic compensation for reactive power become greater and greater. since ertan hydroplant and 500kv transmission systems in sichuan power system have been operated, many power plants of load center are forced to halt during the high - water period, because the great deal of power is transmitted to far - distance load center. thus the load center loses voltage sustentation and the level of the system stabilization is debased greatly

    四川網的二灘水站和500kv輸變系統投入運行后,由於二灘水站的大量力遠距離輸送至負荷中心,迫使負荷中心的火機組在豐水期大量停機,使負荷中心失去支撐,大大降低了網的穩定水平;同時,因為四川網中的無功裝置全為靜態無功容器(或抗器) ,這些設備只能在系統正常運行狀態下起到無功支撐的作用,而在網出現事故時,不但不能起到支撐作用,反而會促使崩潰事故的發生。
  8. The key items include the car sinking, constant speed characteristics, inspection function, auto relevelling function and level accuracy, etc. the research contents focus on the following three parts : firstly, research on effects of system parameters on car sinking has been completed. secondly, the constant speed performance with the compensation of internal leakage of pump / motor is improved. lastly, research on improvement of the car level accuracy and contrast to that of traction elevators is presented, and the reasons of low car level accuracy of hydraulic elevators are discussed

    重點研究了三方面內容:一是研究了停層沉降特性及影響梯轎廂停層沉降特性的各種因素;其次是通過負載泵馬達內泄漏來改善梯轎廂速度穩定性;最後是液梯平層精度的理論和實驗研究,並與曳引梯的理論模型進行了對比,闡述了液梯平層精度低的原因,理論探討了影響液梯平層精度的主要因素。
  9. On the base of widely investigating and researching, author deems that the conventional reactive power compensation devices used by consumer had many defects with among others : lower response time, remaining residual voltage on the compensation capacitors, and so on. because of existing improper trigging time, it is impossible to realizing balance compensation for 3 - phrase unbalance loads

    本文在充分調研的基礎上,認為目前採用的傳統的無功功率裝置存在響應速度慢、觸發時刻不合適、容器上有殘、不能實行三相平衡、對網產生污染、不能消除負荷本身產生的高次諧波等弊病。
  10. First the paper use the different four network operating condition as the primary given conditions and set the 330 / 220kv transformer tap changer position in the standard position, adding the paralleled capacitor bank sets one by one into the network to change the amount of the input reactive power, thus obtained four sets of the 330kv and 220kv bus voltage and the active and reactive power losses changing curves

    進而研究了在每一確定並聯容器組投入量條件下,隨聯變調檔位變化而產生出的一組並聯量、母線與損耗的變化曲線。進而選出了隴南網在四種選定網運行方式下、有功損耗最小條件下的最優綜合控制組合曲線。
  11. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及網潮流,總結出了如下規則:隴南網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯容器作為主要措施,再輔助以選擇合適的主變有載調分接頭來調節,達到控制網內無功潮流分佈合理、各變站母線在理想的范圍內時網有功損耗最小,從而也提高了網安全運行水平及供質量。
  12. With the consideration of most of our transformers " taps are changed manually and some fluctuate unnecessarily, this paper presents a supervision system of oltc based on plc control technique. then we combine this system with reactive power compensate device such as shunt capacitor to design a new supervision system of substation voltage and reactive power synthetic control based on plc fieldbus

    針對國內變調整大多依靠人工調節,且有載調器( oltc )分接頭動作頻繁的特點,本文提出了基於plc控制技術的有載調監控系統的研製方法,並以此監控系統為基礎,結合併聯容器組等無功設備,設計了一種基於plc現場總線的變無功監控系統。
  13. The main contents to be studied and solved are shown as follows : designing scheme of the error compensation system, studying and designing the signal conditioning circuit, designing the data - acquisition circuit, designing and realizing the max1457 software development system. the compensating circuit is designed in virtue of the signal conditioning chip max1457 as its core. the data - acquisition circuit is designed in virtue

    硬體方面,根據總體方案設計了以信號調理晶元max1457為核心的路;以max1401為核心的數據採集路,用來採集傳感器的和max1457輸出;設計了max1457路, max1457的是失調dac和靈敏度dac的參考,採用了ad586給max1457提供精密5v
  14. Dynamic voltage restorer ( dvr ) is an important member of custom power family. it can compensate voltage harmonic, fliker, sag, swell, unbalance, and has the advantage of high performance / price, so it is necessary to investigate the theory and operation of dvr

    動態恢復器( dynamicvoltagerestorer ? dvr )是custompower家族的一個重要成員,它可以補償電壓的跌落、突升以及諧波,具有高性價比的優點。
  15. According to zero sequence voltage distribution from system zero sequence impedance to shunt reactor zero sequence in zero sequence circuit, the zero sequence voltage at the terminal of shunt reactor and the zero sequence compensating voltage at neutral are compared in the scheme

    即根據零序網路中零序在系統零序阻抗和抗器零序阻抗上的分佈情況,通過直接比較抗器首端零序抗器末端中性點的零序補償電壓的幅值大小,來判別抗器匝間故障。
  16. A deadbeat controller is utilized in the stationary frame, eliminating the machine back electro motion force with an assumption that it is a constant in one sampling interval

    通過差分消去機模型中的反動勢,利用補償電壓進一步消除流誤差。
  17. After getting the experiment data, the resistance value and the deviation value of compensation voltage can be calculated by the two algorithms which can be realized by vb program language and math software such as matlab and maple

    得到採集數據以後,通過vb編程語言, matlab和maple數學計算軟體編程,利用最小二乘法和最佳一致逼近演算法,計算出網路的阻參數和補償電壓的擬合差值。
  18. At first, it describes structure of the full - length prototype, manufacturing craft and prepare to work, including sting, sealing, wire tension and leak current measurement, mounting of the preamp, gas system, high voltage system, reduction of noise and so on. the construction of full - length prototype provided valuable experience and important reference to the besiii drift chamber. then good function of the full - length prototype was performed using 55fe 5. 9kev x _ ray source. we can see that the uniformity of gas gain of the full - length prototype is well and it is effective for the compensation voltage to adjust the uniformity of gas gain of the boundary cells

    為了初步測試模型的性能用55fe5 . 9kevx射線進行了氣體增益的均勻性檢測,隨之用55fe5 . 5kevx射線初步測試了模型性能,對部分高補償電壓的設置進行了調整,驗證了對邊界場絲層加補償電壓能夠有效地調節邊緣層氣體增益的均勻性,實驗結果表明全長模型能正常工作並具有良好的性能。
  19. Among them unified power quality controller ( upqc ) is a better set, which can compensate voltage 、 current and promote power quality

    統一能質量控制器( unifiedpowerqualitycontroller ,簡寫為upqc )則是其中一種能夠綜合補償電壓流,改善能質量的裝置。
  20. Abstract : the basic operational principle of the series active power filter, when compensating the voltage type load, is analyzed through its system configuration

    文摘:通過所給出的串聯型有源力濾波器系統結構,分析了其補償電壓型負載的工作原理。
分享友人