調節送風 的英文怎麼說

中文拼音 [diàojiésòngfēng]
調節送風 英文
controlled air distribution
  • 調 : Ⅰ動詞1 (配合得均勻合適) harmonize; suit well; fit in perfectly 2 (使配合得均勻合適) mix; adju...
  • : 節構詞成分。
  • : 動詞1 (運送; 傳送) deliver; carry 2 (贈送) give as a present; give 3 (伴送; 送別) see sb of...
  • : Ⅰ名詞1 (空氣流動) wind 2 (風氣; 風俗) practice; atmosphere; custom 3 (景象) scene; view 4 ...
  • 調節 : regulate; adjust; monitor; measure; take care of; condition; regulation; adjustment; conditioning...
  1. The reheat coil adjusts supply air temperature to offset building heat losses due to transmission.

    再熱盤管調節送風溫度,以補償因傳熱造成的建築熱損失。
  2. Hotel kunlun s guestrooms and suites feature the following amenities and services : high - speed broadband internet access international domestic direct dial fold - out make - up shaving mirror coffee tea - making facilities electronic safe mini bar satellite cable television voice mail bathrobe slippers hairdryer wake - up calls room service bed - side control panel in - room temperature controls shoeshine service

    昆侖客房和套間提供下列物品及服務:高速寬頻上網國內外直播電話折疊式化裝鏡電子保險箱小酒吧有線衛星電視語音信箱浴衣拖鞋吹機叫醒服務房間餐服務床頭控制面板溫度調擦鞋服務
  3. Takes several energy saving measures for air conditioning system, nick a large capacity centrifugal chillers working with variable frequency nil capacity chillers, variable frequency and variable flow control on secondary pump water systems, cooling tower for four - pipe water system in winter, fan - coil unit for commercial peripheral zones aid all - air systems for interior zones, variable frequency control on supply and exhaust air fain, enthalpy control on fresh air cooling in winter and intermediate season

    採用了多項空調能措施:大冷量離心冷水機組搭配變頻小冷量機組,二次泵變頻變流量空調水系統,四管制機盤管冬季用冷卻塔換冷供冷設計,商業外區機盤管、內區全空氣空調系統,機、排機變頻控制,過渡季、冬季利用室外新降溫的焓值控制設計。
  4. Delivery warm air two stages adjustment

    二段調
  5. Thirdly, radiator performance test - bed thermal system control modeling and rule self - organizing fuzzy control simulation were studied. the water supply temperature, radiator inlet temperature, test room temperature based on water temperature regulation, air supply average temperature and test room temperature based on air temperature regulation total five controlled processes transfer function were set. finally, rule self - organizing fuzzy control simulation for two

    通過試驗,辨識了散熱器實驗臺熱工系統中供水溫度、散熱器進水溫度、基於熱水系統調的測試室溫度、平均溫度及基於系統調的測試室溫度共5個被控過程的傳遞函數,並對基於熱水系統調和基於系統調的測試室溫度響應過程進行了規則自組織模糊控制模擬。
  6. Genetic algorithm is used to optimize the parameters of pid controller that is used to control the plant lon ( local operating network ) is designed to control vav air - conditioning system. by this means the static pressure control and minimum total supply air volume control are experimented. the paper analyzes the coupling among loops, the whole system ' s stability and energy saving effect under the two control methods

    針對目前變量空調系統的模型都是用機理建模方法建立的情況,本論文用最小二乘法對機組部分進行系統辨識,建立了水閥?溫度、變頻機?靜壓兩個迴路的模型,經驗證比較接近實際系統;採用遺傳演算法對pid控制器的參數進行尋優,尋優結果令人滿意;設計了變量空調系統的lon控制網路,以此為實現手段,進行了定靜壓控制和最小總量控制,並在兩種控制方式下,分析了各個迴路的耦合情況、兩種控制方式的穩定性和能效果。
  7. A coke oven represents a kind of controlled object with a full spectrum of closely coupled factors, such as distributed parameters, no - linearity, time - dependent change and multi - variable features. among them, the discharge header pressure and fan suction are key parameters, and also constitute strongly coupled variables with very close inter - relation, which are fulfilled by the way of regulating coal - feeding and the rate of primary air supply in practice

    焦爐是一個分佈參數,非線性、時變、多變量緊密耦合的被控對象,其中集氣管壓力和鼓機吸力既是關鍵參數,又是具有緊密關系的強耦合變量,它們均是通過調給煤量和一次量來實現控制的。
  8. This thesis introduced the status quo, existent problems and tasks which still need to be studied in the domestic and international research on ufad ( underfloor air distribution system ), expounded the principle and characteristic of ufad. compared with the traditional mixed ventilation, this thesis pointed out ufad has advantages of specially ventilated air organize, higher ventilation efficiency, flexible collocation, optionally accommodate to realize local environment in control of individual and satisfy personal request for the thermal comfort, and energy saving, and it is a ventilated way of all for human which has broad development foreground

    本文介紹了地板調系統在國內外的研究現狀、存在的問題以及仍需研究的課題,簡述了地板的原理與特性,並與傳統的混合通方式進行了比較,指出地板有獨特的通氣流組織、較高的通效率、布置靈活、能夠隨意調實現局部氣候環境的個人控制滿足個人熱舒適性要求以及能的優點,是一種充分體現以人為本的通方式,具有廣闊的發展前景。
  9. Adopted the questionnaire form to do subjective estimation for thermal sensation 、 thermal comfort 、 effects of ventilation air change and so on in ceiling air conditioning system, parietal air conditioning system and ufad. and tested air parameters and calculating estimated indexes that are used to reflect thermal environment and thermal comfort. the results suggested the characteristic of saving energy and improving indoor air quality

    通過問卷調查形式,對頂棚、側及地板三種方式下的人體熱感覺、熱舒適感及通換氣效果等進行了主觀評價,並通過對環境參數的測量,計算反映熱環境和熱舒適性等的評價指標,結果表明地板調系統具有能和提高室內空氣品質的特點。
  10. Directing against state of affairs at present, such as margin of type - selection parameters being selected comparatively large during design stage of air fans for boilers in thermal power plants, the opening degree of air fans in operation being often smaller ( for adjustment of inlet regulator ) or operation at lower revolution speed ( for speed - regulating operation mode ), and efficiency of air fans being lower etc., factors and corresponding measures having to pay attention in margin selection of air fan ' s parameters have been put forward through analysing practical example of retrofitting forced draft fans in one power plant, playing certain positive role for energy - saving and benefit - increasing in power plants

    摘要針對目前火力發電廠鍋爐機在設計選型時參數裕量選取較大,運行時門開度較小(對入口調調)或低轉速運行(調速運行方式) ,機效率較低的狀況,通過對某電廠機改造實例的分析,提出了在機參數選擇中的裕量選取需要注意的因素及相關對策,對電廠的能增效有一定的積極作用。
  11. The experiment ' s results show that the system is stable under the static pressure control and energy saving under the minimum total supply air volume control. although the terminal dampers ' s tuning time is prolonged under the minimum total supply air volume control, it can be reduced by adopting the appropriate sampling time when debugging the system. from all of this we can conclude thart the minimum total supply air volume control has a good application perspective

    實驗結果表明,定靜壓控制方式下系統較為穩定,最小總量控制比定靜壓更加能,但它延長了末端閥位的調時間,在系統調試時,我們可通過選擇合適的采樣時間來縮短閥門的調過程,所以最小總量控制具有廣闊的應用前景。
  12. It was analyzed the variables in the thermal comfort control in train air - conditioning by fuzzy control technique and get the air temperature as the parameter by directly control

    對熱舒適控制中的各變量進行了分析,採用模糊控制技術,選擇空氣溫度作為直接受控的參數,並通過調節送風量來實現。
  13. Single - duct air distribution method should be used when designing the full air conditioning system with no special requirement

    設計全空氣空氣調系統並當功能上無特殊要求時,應採用單方式
  14. To this model, synthetically consider running working condition, the archetype jet which is 240mm should be the jet outlet of this stratification air - condition. so, it can not only satisfy air - condition effect, but also save energy

    對于本模型而言,綜合考慮三個季的運行工況,應採用240mm的原型噴口作為該分層空調口,才能達到既滿足空調效果,又能能的目的。
  15. Single - duct air supply mode should be adopted in designing all - air air conditioning systems when no particular functions are required

    設計全空氣空氣調系統並當功能上無特殊要求時,應採用單方式
  16. As new terminal equipment in air - conditioning, the mechanism of radiant floor is heating or cooling the room mainly through radiation and convection

    輻射地板作為一種新型空調末端設備,主要利用輻射和對流形式對房間供冷或供暖;與常規空調相比,具有熱舒適性好、能、美觀、對環境影響小等優點。
分享友人