象形位移構造 的英文怎麼說

中文拼音 [xiàngxíngwèigòuzào]
象形位移構造 英文
keazoglyph
  • : Ⅰ名詞1 (所在或所佔的地方) place; location 2 (職位; 地位) position; post; status 3 (特指皇帝...
  • : Ⅰ動詞1. (移動) move; remove; shift 2. (改變; 變動) change; alter Ⅱ名詞(姓氏) a surname
  • : Ⅰ動詞1 (構造; 組合) construct; form; compose 2 (結成) fabricate; make up 3 (建造; 架屋) bui...
  • : Ⅰ動詞1 (做; 製作) make; build; create; produce 2 (假編) cook up; fabricate; concoct 3 [書面語...
  • 象形 : [語言學] pictographic characters or pictographs e g 日 (sun) and 月 (moon) one of the six cat...
  • 構造 : structure; construction; constructional detail; tectonic; structural; makeup; anatomy; constituti...
  1. In this thesis, four types of steel beam - rectangular cfst column connections, including normal welded flange plate ( wfp ) connection, bolted flange plate ( bfp ) connection, stiffened end plate ( sep ) connection and double split - tee plate ( dst ) connection, were designed based on the configuration of steel frame connection. total 8 models, 2 models of each kind of connections were tested under low - reversed cyclic loading at the end of cfst columns. the relationships between force and displacement at the end of columns, the relationships between the moment and rotation of the joints, degradations of strength and stiffness, ductility, failure mechanism and failure characteristics of these four connections under different axial - compression ratios were presented

    本文借鑒鋼框架節點,設計了四種類型矩鋼管混凝土柱與鋼梁連接節點,包括常規栓焊( wfp )節點、翼緣全螺栓連接( bfp )節點、雙t板連接( dst )節點以及加勁端板連接( sep )節點,進行了四類節點8個模型試件在柱端低周反復荷載作用下的抗震性能試驗研究,比較了不同軸壓比下節點的滯回性能、強度與剛度退化、延性、破壞機理與破壞特徵,主要結論有: 1 、節點的滯回曲線與轉角滯回曲線為塊型分佈,沒有或略有捏攏現,耗能能力強; 2 、軸壓比對節點滯回曲線有顯著影響,全部節點都有顯著的剛度退化; 3 、與轉角骨架曲線在峰值荷載後有較長的水平或下降段,具有良好的延性性能; 4 、從整體抗震性能上看,翼緣全螺栓連接節點、雙t板連接與加勁端板連接節點都優于常規栓焊節點,可在實際工程中加以推廣。
  2. Then the coupling beams with new reinforcement layout were made an inquiry into, and the improvement on the seismic behavior by coupling beams diagonally reinforced with a few rows in end regions was found out at last, based on the observations of the experimental phenomena and the analysis of the measurement result, and by the comparison of seismic behavior by making use of hysteretic response, ductility and energy dissipation behavior, a conclusion is presented : the code for design and construction of reinforced concrete high - rise structures ( the draft asked for advise hi 2000 ) ca n ' t ensure that the coupling beams have fairly good seismic ductility ; the result of improvement of the seismic ductility of the coupling beams by the increase hi stirrups besides the strengthen of longitudinal detailing reinforcement was n ' t obvious ; the coupling beams diagonally reinforced with a few rows in end regions have fairly good mechanisms, and the ductility and the behavior of energy dissipation are better than conventionally reinforced concrete coupling beams, so it is suitable to te tised in short coupling beams

    本文通過對三根小跨高比(均為l h = 1 . 0 )剪力墻洞口連系梁在低周反復荷載作用下的試驗,了解了嚴格按《鋼筋混凝土高層建築結設計與施工規程》 ( 2000年徵求意見稿)設計的連梁具有的抗震性能,研究了採取增大連梁配箍量同時加強縱向筋的方案對抗震性能的影響,並進一步對新的配筋式的連梁進行了探討,了解了在連梁梁端配置多排交叉斜筋方案對連梁抗震性能的改善。通過對試驗現的觀察和量測結果的分析,利用荷載?滯回曲線、延性和耗能性能等指標對各個試件的抗震性能進行了比較,最後得出結論: 《鋼筋混凝土高層建築結設計與施工規程》 ( 2000年徵求意見稿)不能保證小跨高比連梁具有較好的抗震延性:通過增大連梁配箍量同時加強縱向筋的方案對改善連梁的抗震延性的效果不太明顯;梁端配置多排交叉斜筋的連梁具有相對較好的受力性能,其延性和耗能性能等各項性能指標均優于普通配筋連梁,宜在深連梁中採用。
  3. Gas chimney is one of seismic anomalies resulted from vertical fluid migration, which is the interactional outcome due to overpressure, low stress and shale harrier

    摘要氣煙囪是由於天然氣(流體)垂向運在地震剖面上成的含氣異常現,是氣藏超壓、低應力部和泥頁巖封隔層3種因素綜合作用的結果。
分享友人