負序電流 的英文怎麼說

中文拼音 [diànliú]
負序電流 英文
negative sequence current
  • : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
  1. There is great change of negative current component when it happens the line - open fault. it is marked as the occurrence of the fault. and it can be concluded the phase characteristic of negative current in the line. in the transient course, there are plenty of harmonics in the fault line. through the transient analysis, it is drawed that the amplitude of each harmonic in fault phase is greater than other phases. harmonic current in fault line is far greater than other normal lines

    發生斷線故障以後,線路中會出現負序電流的突變,可以作為故障啟動判斷的標志,並且通過分析得出了故障時基波的相位特點。在故障暫態過程中,故障中含有大量豐富的諧波成分,各次諧波在故障期間有突變,並且衰減很快。
  2. The device can protect start - up status and running status of asynchronous motors by differential protection, over current protection, negative - sequence current protection, zero - sequence current protection, inverse time current protection, under - voltage protection and so on, can measure every kind of electricity, and can process the function of telecontrol, telemetering and telecommunication

    其依靠差動、速斷、、反時限、零和低壓等保護方法實現了片動機的運行、啟動和自啟動過程進行保護,並實現各種量的計量,同時具有遙控、遙測、遙信的功能。
  3. This paper focuses on the control strategies to improve the performance of the three - phase ac - dc pwm voltage - source - converters ( vsr ) under unbalanced power supply. the problems such as negative sequences current, voltage and current harmonics and un - constant ( un - smooth ) power flow from ac to dc side are discussed in this paper. the analytical solutions for negative sequence current and harmonic current elimination are obtained by fully feed - forward of negative sequence voltage and producing a non - harmonic current command of the inner - loop

    網不平衡時,基於網平衡為約束條件設計的三相vsr將出現不正常運行狀態,比如三相vsr交中出現分量,使交嚴重不對稱;直壓和交中出現非特徵諧波分量,使直壓和交波形發生嚴重畸變;三相vsr從網吸收不平衡的瞬時功率等一系列問題。
  4. This paper describes mainly system functions, measuring methods, circuit design, software program and errors analysis of a new type of measuring instrument. this instrument can measure and monitor electric parameters in single - phase circuits, three - phase ( three - wire or four - wire ) circuits. this system can be applied to electric devices and power plants, transformer substations with harmonic pollution. it can measure current, voltage, power, energy, frequence, power factor etc. it also can detect load quality, phase sequence, alarm, display and print results, as well as detect and dispose negative power

    該儀器適用於含有諧波污染情況下的機設備現場、發廠、供局、企業變所現場,可用來測量壓、有功功率、無功功率、視在功率、有功能、無功能、視在能以及頻率和功率因數等參數,並具有載性質(感性、容性)判別,正、逆相判別指示功能;超限報警功能;列印記錄功能和功檢測及處理功能。
  5. The negative sequence current of impedance - matching balance transformer

    阻抗匹配平衡變壓器的負序電流
  6. Harmonics, reactive power, voltage flicker and negative - sequence current of power grids can affect the power quality and harm the power equipment badly

    摘要網中存在諧波、無功、壓閃變及負序電流等問題,嚴重影響能質量,危害力設備。
  7. This paper analyses the test results gained by mixed simulation, and validates the reliability of the use of transient zero current and negative current in fault identifying

    文中討論了負序電流的分佈及提取問題,試驗數據同樣表明負序電流用於單相接地故障識別是可行性的。
  8. So it can be used for single - phase fault identifying. this paper discusses the size of the negative current and the method of analyzing it. numeral simulation shows the feasibility of it

    由於負序電流在故障線路和非故障線路上具有顯著差異,故本文也研究了將負序電流作為故障特徵量的可行性。
  9. Now the affect and the measure of hypo _ harmonics is in the research. the influence of negative sequence is almost eliminated along with the enlargement of the system ' s capacity and the alternate connection of traction substations. the fixed parallel compensate equipment applied in traction substations consist of a constant capacitor and a constant inductance, so its output is constant

    負序電流的問題已經因系統容量的增大、牽引變所採用輪換接線方式而基本解決,力部門實行的「反轉正計」 ,使採用對無功功率固定補償方式由於牽引荷變化頻繁而出現補償容量不足或過補償現象,難以達到滿意效果。
  10. In at power supply system some transformers with special connection mode, such as scott transformer, anti - scott transformer, balance transformer and so on, are usual used. the voltage ratio is one of important parameters of transformer

    採用斯科特變壓器、平衡變壓器等特殊接線方式變壓器作為主變壓器,能有效抑制負序電流,減少有功損耗和壓損失,提高牽引機車的過載能力。
  11. Unified power flow controller ( upfc ) is one of the most powerful and most promising controllers of facts. if we use upfc to control the transmission parameters, terminal voltage, line impedance and phase angle in normal situation and use it to compensate zero sequence and negative sequence currents when one of transmission lines is cut off, we can implement two phases operating in high voltage transmission lines, which can improve stability and reliability for the transmission system

    統一潮控制器( upfc )是功能最強、最具發展潛力的靈活交系統( facts )控制器之一,如果在常規條件下,用upfc實現輸線路的壓調節、移相、潮控制、阻尼振蕩等功能,在發生單相永久性接地或單相斷路故障時,由傳統的三相跳閘改為單相跳閘,用upfc的並補來濾除兩端系統的零負序電流,用upfc的串補來提高輸線的傳輸功率,以實現兩相長期運行,那麼輸系統的穩定性、可靠性將大大提高。
  12. Tangyin substation is an important substation which has two transformer of 120mva, eight 220kv lines and three 110kv lines. tangqian line is a 110kv line specially for traction transformer substation. because traction load is high - power nonlinear and asymmetry. it will produce much harmonic and negatvie sequence current, which have done harm to compensation capacitors of tangyin substation. in recent years, the tang6c capacitor often interrupted and in 2001 july the tang7c capacitor ' s discharge pt exploded

    湯陰變站是豫北一座樞紐變站,有2臺120mva的主變, 8條220kv線路和3條110kv線路,其中的湯牽線是專為牽引變站供的110kv線路。由於力機車屬于大功率的非線性荷,且三相不對稱,在其運行過程中必然會產生較大的高次諧波和負序電流
  13. As a result, this paper gives a corresponding harmonic prevent me asure. finally, according to the asymmetrical characteristics of electrical traction loads, this paper studies the negative sequence currents under different loads and makes a piece of advice for reducing the negative sequence currents produced

    最後,還根據力牽引荷三相不對稱的特點,分析了阻抗匹配平衡變壓器在不同荷條件下的負序電流,對如何減小力牽引荷的負序電流提出了一點建議。
  14. Active power filter ( apf ) is an advanced power electronic device , which can be used for compensating harmonics, reactive power and negative sequence current. compared with conventional compensation devices, active power filter has advantages of real - time and accuracy

    有源力濾波器是一種新型諧波、無功補償裝置,和傳統的補償裝置相比,有源力濾波器具有很大的優勢:可以對諧波、無功以及負序電流實現實時、準確的補償。
  15. The following is the main works and conclusions of this thesis. the novel upfc needs high power rate because it is generally used in high voltage transmission lines. after studied high - power converters and the literatures of upfc, the main circuit topology of novel upfc base on diode - clamping multilevel inverter is presented and the principle of using novel upfc to eliminate zero sequence and negative sequence currents is analyzed

    本文所做的主要工作及得出的主要結論如下:由於upfc一般用於高壓輸線,其功率等級要求很高,在綜合研究大功率變換器和upfc現有文獻的基礎上,提出了基於二極體箝位多平變換器的新型upfc的主路拓撲,分析了用其來濾出高壓輸線非全相運行時所產生的零負序電流的原理。
  16. The electric power harmonic comprehensive control system with low cast and high security is applied in this article. it adopts that sourced compensation links with non - sourced compensation herewhich the former is realized by high frequency pwm control technology and the latter is carried out by crystal switch formed by non - flow and over - voltage. it can realize stepless modulation with imaginary power, mightiness compensation of harmonic and negative electricity, and circuitry consumption debasing are achieved

    提出採用有源補償與無源補償相結合的力諧波綜合治理技術及裝置,無源部分採用無涌和過壓的晶閘管控制容器技術實現,有源部分採用高頻pwm控制技術實現,成本低、可靠性高、可實現無功功率的無級調節、強力補償諧波負序電流,降低線路損耗。
  17. In order to consider the different heating of positive - sequence current and negative - sequence current of the motor stator generally, the equivalent current is adopted instead of the traditional phase current. the way how to gather positive - sequence current and negative - sequence current is brought forward, and the recurrence fourier - algorithm is adopted to calculate the effective value of current and voltage, the effective value of positive - sequence current and negative - sequence current

    為了全面考慮感應動機定子正負序電流的不同發熱效應,提出了正負序電流獲取的方法,並採用遞推傅氏演算法來實現壓及分量的有效值的計算。
  18. This paper brings forward that asvg is capable of compensating harmonic, negative sequence and zero sequence currents. so asvg can synchronously compensate the reactive current and harmful currents in three - phase four - wire unbalanced system

    本文提出靜止無功發生器還具有抑制諧波和濾除、零的能力,從而可以用於對三相四線制不平衡系統同時進行無功補償和有害濾除。
  19. The detecting techniques of harmful currents, the modulation methods of novel upfc and the balancing control of capacitors voltage on dc link are studied thoroughly. in order to be fit for three - phase four - wire system, the method of balancing control using chopper presented in literature [ 29 ] is mended

    分析了零負序電流對新型upfc直壓的不同影響,對文獻[ 29 ]提出的傳統upfc的直側各壓的均衡控制方法進行了仔細研究,提出了採用b型直斬波器來控制新型upfc的直壓的新方法。
  20. By study, we can know that when one - phase ground fault happens on the line, more far the fault location is from where relays place, more less is the difference of the two zero sequence currents, while hen one - phase ground fault happens on the other line, more far the fault location is from where relays place, more is the difference of the two zero sequence currents

    研究表明,當本回線路發生單相接地短路時,在通過公式計算得出的一特定值為正時,離保護安裝處越遠,本回線路零與非故障線路零相位差值越小;當另一回線發生單相接地短路時,離保護安裝處越遠,本回線路零與故障線路零相位差值越大,該值為時則反之。
分享友人