起搏電流 的英文怎麼說

中文拼音 [diànliú]
起搏電流 英文
pacemaker current
  • : 起Ⅰ動詞1 (站起; 坐起) rise; get up; stand up 2 (取出; 取走) draw out; remove; extract; pull 3...
  • : 動詞1. (搏鬥) combat; fight; struggle; wrestle; strike 2. (撲上去抓) pounce on 3. (跳動) beat; pulsate; throb
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
  1. It is necessary to control the mechanical stimuli precisely in the studies of cardiac mechano - electrical feedback ( mef ). in the present study a ventricular pressure - clamping system has been developed, which can be applied to isolated - perfused rabbit hearts. controlled by a computer, this system not only can make the left ventricle follow a command defining the same pressure wave as that during a beating cycle under physiological condition, but also deliver mechanical stimuli with a proper waveform to the ventricle at a particular time phase. this system integrates multiple functions, including perfusing, pacing, recording of electrocardiogram and monophasic action potentials, and clamping and measuring of ventricular pressures in isolated - perfused hearts. thus, it is a distinct system for investigating the phenomena and mechanisms of cardiac mef at organ level

    在心臟機械反饋的研究中準確控制機械刺激是非常重要的.本研究室構建了一套適用於離體家兔心臟的心室壓力鉗系統.該系統通過計算機控制壓力鉗,不僅能模擬正常生理條件下左心室的壓力波形,還能在心室活動周期的特定時相、以適當波形對心室施加機械刺激.該系統集心臟灌、表面心圖記錄、單相動作位記錄、心室壓力鉗制與測定等多種功能於一體,特別適用於器官水平上觀察機械反饋現象並探討其機制
  2. Abstract : it is necessary to control the mechanical stimuli precisely in the studies of cardiac mechano - electrical feedback ( mef ). in the present study a ventricular pressure - clamping system has been developed, which can be applied to isolated - perfused rabbit hearts. controlled by a computer, this system not only can make the left ventricle follow a command defining the same pressure wave as that during a beating cycle under physiological condition, but also deliver mechanical stimuli with a proper waveform to the ventricle at a particular time phase. this system integrates multiple functions, including perfusing, pacing, recording of electrocardiogram and monophasic action potentials, and clamping and measuring of ventricular pressures in isolated - perfused hearts. thus, it is a distinct system for investigating the phenomena and mechanisms of cardiac mef at organ level

    文摘:在心臟機械反饋的研究中準確控制機械刺激是非常重要的.本研究室構建了一套適用於離體家兔心臟的心室壓力鉗系統.該系統通過計算機控制壓力鉗,不僅能模擬正常生理條件下左心室的壓力波形,還能在心室活動周期的特定時相、以適當波形對心室施加機械刺激.該系統集心臟灌、表面心圖記錄、單相動作位記錄、心室壓力鉗制與測定等多種功能於一體,特別適用於器官水平上觀察機械反饋現象並探討其機制
  3. The 12th world productivity congress will be held in hong kong in 2001, the world congress of accountants in 2002, the international cardiac pacing and electro physiology society world symposium in 2003, and the asia pacific dental congress in 2004

    二零零一年舉辦的第十二屆世界生產力會議;二零零二年舉辦的世界會計師大會;二零零三年舉辦的國際心臟及生理會之世界會議,以及二零零四年舉辦的亞太區牙科會議。
  4. Our item choiced msp430f149, a sort of singlechip as controller, designed our hardware electrocircuit to get the pulse wave singnal, and used msp430f149 to continuously search and calculate the peak - peak value of the pulse wave, and compute oxygen saturaction. in our study, in order to hurdle the dirft of baseline caused by the physiological difference of human bodies. we designed one circuit which can automatically regulate of the baseline of signal

    本文以msp430f149晶元為控制器,設計硬體路提取脈波信號,連續檢測脈波峰?峰值,計算氧飽合度。本課題採用了基線自動調節路,以克服不同人體生理差異引的基線漂移;設計了直截取路和可控積分放大路,以滿足臨床連續監測的特殊需要,解決信號飽和問題。
分享友人