跳動測量 的英文怎麼說

中文拼音 [tiàodòngliáng]
跳動測量 英文
pulsation measurement
  • : 動詞1 (腿用力彈起) jump; leap; skip; bounce 2 (彈力使物體突然向上移動) spring; leap 3 (一起...
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • 跳動 : move up and down; jitterbug; jitter; beat; pulsate; bounce; jump; kick; throb
  • 測量 : measure; survey; gauge; meter; measurement; measuring; surveying; mensuration; metering; gauging;...
  1. Other common devicesintravenous medication pumps allow the nursing staff to titrate medications ; foley catheters and urine collection bags aid in monitoring urine output ; sequential compression devices squeeze the lower extremities and reduce the incidence of deep venous thrombosis ; transvenous pacemakers stimulate the patient ' s heart to beat ; dialysis machines remove fluid and correct electrolyte and acid - base disturbances ; intraaortic balloon pumps assist the heart ' s contractility ; and neurologic monitoring systems measure intracranial pressure

    其他常用裝置靜脈內給藥泵由普通護士用於滴定藥物;弗利氏導管和集尿袋幫助監排尿;連續壓迫裝置擠壓下肢,減少深部靜脈血栓形成;經靜脈起搏器刺激病人心臟;透析儀除去液體,糾正電解質和酸堿紊亂;主脈內氣囊泵支持心臟收縮;神經病學監系統定顱內壓。
  2. The subject for different process technology and surface treatment of crank takes tracking checkout for its internal stress, analyses relation of jumping measurement, deformation measurement, recovery measurement and stress change, finds the reason and usual law of jumping overproof of crank. through cold pressure alignment, hot pressure alignment, support aged alignment and so on methods for 42crmo steel crank, the subject checks change of stress in the process of alignment and change of tissue and property after alignment for crank, and gives comprehensive evaluation for every alignment technology, then give safe and feasible technology parameter

    本課題主要是對不同加工工藝及不同表面處理過程的曲軸,對其內應力進行跟蹤檢,分析各工藝過程中、變形、恢復與應力改變的關系,找出曲軸超差的原因和一般規律。通過對42crmo鋼曲軸進行「常溫壓力校直」 、 「熱壓力校直」 、 「支撐時效校直」等方法的校直,檢校直過程中曲軸應力的變化及校直后組織和性能的改變,進而對各校直工藝進行綜合評價,給出安全可行的工藝參數。
  3. The key problems of gps carrier phase measurement are how to solve the integer ambiguity of gps carrier and how to detect and compensate the cycle slip of gps carrier in the period of navigation process

    載波相位定位的關鍵問題是如何確定整周模糊度和周的探和修復。本文對此問題展開研究,討論了在載體態運行環境下,態整周模糊度問題和周的探與修復問題。
  4. Measurement of connector ferrule inside and outside diameter circular runout

    連接器套管內部和外部徑向
  5. In the course of measurement of workpiece face runout, variance method of the most species based on separability and image edges distilling based on morphology and marr filtering based on edges segmentation are used to enhance effectively accuracy of image segmentation and edges distilling. accuracy of measurement of face runout is enhanced effectually by use of least square method of compressing rectangle fitting edge of image and transforming of dft

    該系統在工件端面跳動測量過程中,採用了基於可分性的最大類間方差法和形態學邊緣提取以及基於邊界分割的marr演算法,使圖像分割和邊緣提取的準確性得到了很大的提高;用壓縮矩形的最小二乘法擬合工件端面圖像的邊緣以及用dft變換對工件端面的進行,使端面跳動測量的準確性得到了很大的提高。
  6. On the basis of current investigation of both the domestic and foreign and current level of development, and contraposing difficulties and keys of autofocusing and measurement, this paper brings forward system of autofocus and measurement based on techniques of image processing of ccd. this system possesses merits of fast speed, high precision, small bulk and large dynamic range. it is able to carry out needs of fast, accurate, large range autofocusing and requests of noncontact and online measurement of workpiece face runout

    本論文根據目前國內外現狀和發展水平,針對自聚焦和端面跳動測量的關鍵點和難點,在普通光學儀器的基礎上提出了一種基於ccd圖像處理技術的圖像式自聚焦及其系統,該系統具有速度快、精度高、態范圍大、體積小等優點,實現了快速、精確、大范圍的自聚焦和對工件端面進行非接觸、在線的要求。
  7. Intravenous medication pumps allow the nursing staff to titrate medications ; foley catheters and urine collection bags aid in monitoring urine output ; sequential compression devices squeeze the lower extremities and reduce the incidence of deep venous thrombosis ; transvenous pacemakers stimulate the patient ' s heart to beat ; dialysis machines remove fluid and correct electrolyte and acid - base disturbances ; intraaortic balloon pumps assist the heart ' s contractility ; and neurologic monitoring systems measure intracranial pressure

    靜脈內給藥泵由普通護士用於滴定藥物;弗利氏導管和集尿袋幫助監排尿;連續壓迫裝置擠壓下肢,減少深部靜脈血栓形成;經靜脈起搏器刺激病人心臟;透析儀除去液體,糾正電解質和酸堿紊亂;主脈內氣囊泵支持心臟收縮;神經病學監系統定顱內壓。
  8. Fibre optic communication subsystem basic test procedures - test procedures for digital systems - jitter transfer function measurement

    光纖通信子系統基本試程序.數字系統試程序.傳輸功能
  9. Fibre optic communication subsystem basic test procedures - part 2 - 5 : test procedures for digital systems - jitter transfer function measurement

    光纖通信亞系統基本試驗過程.第2 - 5部分:數字系統的試驗過程.圖像傳輸功能的
  10. We can get information of particle size with the measuring jumpiness of light scattering energy

    通過對7角的散射能能夠得到顆粒大小的信息。
  11. The smaller of particle size, the bigger of light scattering energy jumpiness, which reflects jje ( % hi } ) " " & " a ' ^ tjjij ri. ' ff - ' fe ift a " _ abstract that brownnian motion of small particle is more acute than big particle ' s

    ( 2 )樣品靜態試中發現在7角處,顆粒粒徑越小,能越大,這與顆粒在液體中的布朗運規律相符合。
  12. The first part concerned the self - conceptions of competence in the field of children ' s physical exercise. it was made up of three experiments : experiment i used bandura ' s classical pattern of the measurement of self - efficacy for reference. before and after the children ' s three trial jumps respectively, they were asked to assess their abilities to fulfill a series of tasks of standing long jumps from easy to difficult

    第一部分是幼兒身體運領域能力自我知覺的研究,由三個實驗組成:實驗一借鑒bandura自我效能的經典模式,在幼兒三次集中試之前、之後,分別讓幼兒就自己在完成從易到難的一系列立定遠任務上的能力及把握程度做判斷,並在其後再對自己最大能力分別做一個單項目的總的判斷,比較試前泛化經驗和試后即時直接經驗對幼兒能力知覺的影響作用,並對比單項目判斷和多項目判斷對幼兒能力自我知覺的反映情況。
  13. Run out requirements and measuring methods of automotive wheels

    汽車車輪的要求和檢方法
  14. Verification regulation of radial ball bearing sway tester

    深溝球軸承跳動測量儀檢定規程
  15. And accordingly the new - type measurement is put forward in the paper, which is to increase the radial micrometers on the primary measuring - piece surface

    提出新型滾輪法大直徑的方法,即在原有滾輪頭上增加工件表面徑向微儀,來實現形狀誤差
  16. Welding - acceptance inspection of electron beam welding machines - part 5 : measurement of run - out accuracy

    焊接.電子束焊接機的驗收檢驗.第5部分:電子束徑向精確度的
  17. Precise kinematic gps surveying in single - baseline mode is investigated with the emphasis on the ( near ) instantaneous ambiguity resolution for short - baselines, on the ambiguitiy resolution for long - baselines and on quality control. the main achievements of this paper are as follows : 1

    本論文針對單基線模型,就短基線模糊度快速解算、中長距離模糊度解算、 gps(包括定位、速和姿態)以及周與修復等質控制問題展開研究。
  18. My track plot has odd jumps and / or the measured distance seems to be too big

    我的路徑記錄點有不規則的,而且距離似乎過大。
  19. Connectors for electronic equipment - tests and measurements - test 25f - eye pattern and jitter

    電子設備用連接器.試驗和.試驗25f :眼圖和圖像
  20. Because the machine is equipped with jumping mechanism, it is unnecessary to reset the tool after returning grinding wheel for measurement or dressing

    機床設有快機構,因此退出砂輪進行或修正後不必重新手對刀。
分享友人