透光檢驗 的英文怎麼說

中文拼音 [tòuguāngjiǎnyàn]
透光檢驗 英文
candling
  • : Ⅰ動詞1 (滲透; 穿透) penetrate; pass [seep] through 2 (暗地裡告訴) tell secretly; let out; lea...
  • : Ⅰ名詞1 (照耀在物體上、使人能看見物體的一種物質) light; ray 2 (景物) scenery 3 (光彩; 榮譽) ...
  • : Ⅰ動詞1 (查) check up; inspect; examine 2 (約束; 檢點) restrain oneself; be careful in one s c...
  • : 動詞1. (察看; 查考) examine; check; test 2. (產生預期的效果) prove effective; produce the expected result
  • 透光 : photopermeability; pervious to light; translucidus; transmitting
  • 檢驗 : checkout; test; examine; inspect; verify; survey; check;checking;testing;[英國]jerque(指檢查船舶...
  1. Materials and methods the mouse, golden hamster and human sperm were incubated with endotoxin in different concentration for different time to get capacitation, respectively, and ar was induced by progesterone after capacitation, then the rates of capacitation and ar were detected by chlortetracycline ( ctc ) and hoechst 33258 fluorescent staining method. the medium was with endotoxin in different concentration in sperm - oocyte fusion step during ivf, then the fertilization rate was observed. the 1 - cell, 2 - cell and zona - free 2 - cell mouse embryos were incubated in the medium with endotoxin, then the rate of blastocysts was recorded

    方法取小鼠精子10份、金黃地鼠精子6份、人新鮮精液標本10份及人冷凍精液標本9份,分別與不同濃度內毒素共孵育進行體外獲能和孕酮誘導的頂體反應,應用金黴素和dna結合的熒染料hoechest33258雙重熒染色法測精子的獲能率和頂體反應率;小鼠體外受精實的精卵結合環節培養液中加入不同濃度的內毒素,觀察受精情況並記錄受精率;取小鼠1 -細胞胚胎、 2 -細胞胚胎和去卵明帶2 -細胞胚胎,與不同濃度內毒素共孵育進行體外培養,觀察體外發育情況並記錄囊胚率。
  2. Standard test method for fluorescent liquid penetrant examination using the lipophilic post - emulsification process

    利用親脂乳化工藝技術進行熒液滲的標準試方法
  3. On the basis of theory analysis, the average transmitted light intensity ( correspond to dc value ) was determined as characteristic parameter of raw water using photoelectric method for monitoring the fluctuation of transmitted light and photometric dispersion analyzer ( pda ). the dc value was closely related to both particle concentration and surface area of sand clay simultaneously. the experimental results shows that there is an exponential function relation between dc and surface area of sand clay in unit volume water ( sp ) : dc = asbp in which a and b are empirical coefficients. then the formula of macromolecule flocculant dosage is found to be d = f ( dc ) = e ( dc ) f in which e and / are empirical coefficients and the average correlation coefficient equal to 0. 981. so the model of automatical control system of water treatment plant was established using the formula

    應用率脈動測技術和散射顆粒粒度分析儀( pda ) ,通過理論分析,將pda的輸出信號之一? ?平均強度(對應于dc值)作為原水的特性表徵參數, dc值可以同時反映顆粒濃度和比表面積因素的影響,試結果證明, dc值與單位體積水中泥沙顆粒總表面積s _ p之間具有很好的冪函數關系: dc = cs _ p ~ d ,式中c 、 d為經系數,進而得到了以dc值為參數的高分子絮凝劑投藥量公式: d = f ( dc ) = e ( dc ) ~ f ,式中: e 、 f為經系數,平均相關系數達0 . 981 ,利用所建立的公式,建立了前饋? ?后饋聯合控制的在線自動投藥模型。
  4. On the base of studying imaging theory of lens, the imaging theory of laser confocal scanning microscopy was analyzed in detail in this paper, and the advancement of that the optical fiber was applied to the system was described ; on the base of completed the demonstration for whole project, the experiment scheme was designed ; the relationship between the main parameters of key devices and the resolution was deduced, and the requirements of coupling efficiency and vignetting effects to optical system was analyzed ; the design of optical system and the planar scanning controlling circuit was completed ; a new method was put forward to resolved the inherent non - liner scanning problem of the galvanometer scanner by using software liner controlling in circuit design, and the perfect planar scanning was realized ; at last the low noise, high multiple and non - distortion amplify circuit of photoelectric detector was completed

    本文在鏡成像理論的基礎上,系統、深入地分析了共焦掃描顯微成像的機理,論述了應用單模纖的激共焦掃描顯微成像系統的優點;進行了總體方案的論證,並設計確定了單模纖激共焦掃描顯微成像系統的總體方案;從理論上推導分析了解析度要求與試系統中相關器件主要參數之間的關系,分析了系統耦合效率和漸暈現象對學系統的設計要求;完成了方案中學系統和二維掃描控制電路的設計,並在電路設計中採用了用軟體解決流計式學掃描器(振鏡)非線性問題的新方法,能夠實現較為理想的二維模擬掃描;完成了高增益、低噪聲和低失真的探測接收系統的設計和調試。
  5. Optics and optical instruments - test lenses for calibration of focimeters - test lenses for focimeters used for measuring contact lenses

    學和學儀器.焦距計校正用鏡頭.測量接觸鏡組用焦距計用鏡頭
  6. Optics and optical instruments - test lenses for calibration of focimeters - test lenses for focimeters used for measuring spectacle lenses

    學和學儀器.焦距計校正用鏡頭.測量柔性焦距鏡組用焦距計用鏡頭
  7. Optics and optical instruments - test lenses for calibration of focimeters - part 2 : test lenses for focimeters used for measuring contact lenses iso 9342 - 2 : 2005 ; german version en iso 9342 - 2 : 2005

    學和學儀器.焦距計校正用鏡.第1部分:接觸鏡
  8. Optics and optical instruments - test lenses for calibration of focimeters - part 1 : test lenses for focimeters used for measuring spectacle lenses iso 9342 - 1 : 2005 ; german version en iso 9342 - 1 : 2005

    學和學儀器.焦距計校正用鏡.第1部分:眼鏡
  9. Derived from optical waveguide fundamentals, outstanding advantages of mfld in high s / n ratio and sensitivity were theoretically presented. to resolve inconsistent change tendencies of mode - filtered light obtained in bare core sensing system and in modified sensing system, that is, the mode - filtered light signal declines with the increase in analyte ris in bare core sensing system but increases with the increase in analyte ris in modified sensing system, we started with light energy radiation theory, and obtained the details of mfld mechanism by discussing in detail the radiant energy ' s reflection and refraction at the interface, thus establishing a mathematical model of mfld. we concluded that the inconsistent change tendencies of mode - filtered light were essentially coherent

    為了解決實中裸纖體系與修飾纖體系在獲取模式濾信號上出現的不一致現象,即裸纖體系中隨著分析對象的折射率增大,獲取的模式濾信號呈下降趨勢,而在修飾纖體系中分析對象的折射率增大,獲取的模式濾信號卻是增大的,我們從的能量輻射學入手,詳細地討論了輻射能在傳輸路徑上的反射與射,獲得了模式濾信號產生的細節,以此建立了模式濾測的新模式。
  10. By providing regular check - up for these high risk individuals, we will be able to detect and treat the disease at an early stage, which implies a better long - term outcome, " said professor dennis shun - chiu lam, chairman of the department of ophthalmology & visual sciences of cuhk and director of lim por - yen eye genetics research centre

    香港中文大學眼科及視覺科學學繫系主任兼林百欣遺傳眼疾研究中心主任林順潮教授指出:過基因服務,我們可以找出遺傳眼疾的高危人士,例如慢性原發開角型青眼。
  11. By the essential control of the initial stage of - material growth, the high - quality crystal films can be obtained. by using mocvd technology, studies of some kinds of methods such as hydrogen - terminated, nitridation, plasma - assisted, growth of two stages and sputtering buffer layers have been conducted. by measuring of xrd, pl, sem and tem, and analysis of spectra of xrd, raman scatting, oa, and pl at different temperatures, we observed that the crystal quality has been improved markedly

    本文利用mocvd技術,採用各種對si襯底處理的方法,如氫終止法、氮化法、等離子體轟擊方法、兩步生長法、濺射緩沖層法等進行了試與研究,通過x射線衍射技術( xrd ) 、致發技術( pl ) 、掃描電子顯微術( sem ) 、射電子顯微術( tem )等測,並對其x射線衍射譜、拉譜譜、吸收譜及不同溫度下的致發譜分析,發現外延晶體的生長質量得到了明顯提高。
  12. Aqueous fluid volume and [ c1 ~ j were assayed in samples withdrawn by micropipettes. intraocular pressure ( top ), pressure - dependent outflow, and anterior chamber compliance were determined from pressure measurements in response to pulsed and continuous fluid infusions into the anterior chamber using micropipettes. result : in wildtype mice ( gdi genetic background, age 4 - 6 weeks ), iop was 16. 0 ? 0. 4 mmhg, aqueous fluid volume was 7. 2 ? 0. 3 ul, aqueous fluid production was 3. 6 ? 0. 2 ul / hr, aqueous fluid outflow was 0. 36 ? 0. 06 ul / hr / mmhg, and anterior chamber compliance was 0. 036 ? 0. 006 ul / mmhg ( mean ? se, 8 - 10 eyes )

    方法包括:將熒物質用電離子滲的方法穿角膜導入活體小鼠的前房中,然後應用共聚焦顯微鏡根據熒強度變化測量房水生成率;通過顯微注射針吸取房水測房水容積和氯離子濃度;顯微玻璃管刺入前房測量眼內壓,並將生理鹽水分別以連續和脈沖兩種方式注入前房,測量房水間隙的順應性和房水排出與眼內壓的相關性。
  13. Cancer can be diagnosed by x - rays, blood tests, urine tests, stool tests, and procedures to obtain tissue samples from specific or related sites for laboratory examination. what is the treatment

    醫生可過x查、血、尿、大便及進行手術抽取有關部份的組織樣本進行化,作出診斷。
  14. In order to efficiently improve the stability of the apparatus, a dual - optical detection circuit was adopted. to eliminate the multiple scattering effects on transmittance measurements, the range of the transmittance was limited to 70 - 100 % by adjusting the width of the light flow cell and changing the intensity of the incident light through regulating the load voltage of the laser light source. moreover, the data acquisition software was programmed in microsoft visual bas

    通過調節激源負載電壓改變強度及調摘要整測池的寬度,消除了多重散射對率的影響,將率的變化范圍控制在滿足beer1a毗ert定律的范圍內工將溫度、溶液密度和率信號經模數轉換,並用microsoftvisualbasic語言編寫的數據採集軟體,實現了實過程中各被測量的自動連續採集。
  15. Standard test method for fluorescent liquid penetrant examination using the water - washable process

    用水洗工藝技術進行熒液滲的標準試方法
  16. Standard test method for fluorescent liquid penetrant examination using the solvent - removable process

    用溶劑可回收工藝技術進行熒液滲的標準試方法
  17. Standard test method for fluorescent liquid penetrant examination using the hydrophilic post - emulsification process

    用親水乳化工藝技術進行熒液滲的標準試方法
  18. Testing of fibre optic elements ; determination of spectral transmittance of light guides

    纖元件的.第2部分:導體射系數的測定
  19. En 2155 - 7 aerospace series. test methods for transparent materials for aircraft glazing. part 7 : determination of optical deviation

    航空航天系列.飛機上窗玻璃用明材料的方法.第7部分:偏差的測定
  20. New method of testing the manufacturing trace in plastic food bag with polarized light

    偏振射照明塑料保鮮袋加工痕跡的新方法
分享友人