進氣和排氣閥 的英文怎麼說
中文拼音 [jìnqìhébèiqìfá]
進氣和排氣閥
英文
intake & exhaust valves- 進 : 進構詞成分。
- 氣 : Ⅰ名詞1 (氣體) gas 2 (空氣) air 3 (氣息) breath 4 (自然界冷熱陰晴等現象) weather 5 (氣味...
- 和 : 和動詞(在粉狀物中加液體攪拌或揉弄使有黏性) mix (powder) with water, etc. : 和點兒灰泥 prepare some plaster
- 排 : 排構詞成分。
- 閥 : 名詞1 (指在某方面有支配勢力的人物或家族) established house or power group; a powerful person or...
- 進氣 : air admission; admission; inlet; onflow; charging; access of air; admittance; air in; air intake;...
- 排氣 : [機械工程] exhaust; aerofluxus; air out; exit gas; ventilate; atmosphere; vent排氣泵 exhaust pump...
-
The large holes on the left and right represent the inlet and exhausting valve ports respectively.
左右兩側的兩個大孔,分別表示進氣閥孔和排氣閥孔。During the adjustment. it decided the amount and the rate of humidification. the system can test the states of water level by water lever sensor, thereby the main control module can control the entrance and drain of water and give warnings ; as its good man - machine interaction, the system can expediently set the humidity and the amount of humidification and control water - in valve and leading winds through control panel. the system can communicate with computer thereby the net supervise is enabled
本系統主要能夠完成以下功能:採集空氣中的濕度狀態,並送入主控模塊,主控模塊根據現有的濕度判斷是保持原來狀態還是進行加濕以及加濕量的大小和加濕速度等;能夠通過水位傳感器測試水位的狀態,從而通過主控模塊控制進水、排水、預報警、報警等;具有良好的人機交互性,能夠通過控制面板比較方便地進行濕度設定、加濕量設定、進水閥的控制、導風的控制等;能夠和上位機進行通信,從而實現網路監控。Air admittance valves for drainage systems - requirements, test methods and evaluation of conformity
排水系統用進氣閥.要求試驗方法和合格評定The stress of the sliding vane, the axe and the valve are analyzed through ansys, finite element analysis software. it is certain that this paper is of some reference value in designing such kind of sliding vane compressor with a spliced rotary cylinder
接著分析了轉缸鉸接滑片壓縮機中的滑片和轉缸的運動規律,並對滑片進行了受力分析,利用有限元分析軟體ansys分析了滑片、轉子和排氣閥片的強度。The timing - and - quantitation precision injection of lpg was realized with high - speed lpg solenoid valve and a set of electronic control system, which was designed by the author and can flexibly control the gas supply system of lpg. based on the analysis of experimental data got by comparing the performances before and after the application of the set of equipment on lr6105q12 diesel engine, the effects of load, speed and replace ratio, etc on the emissions of smoke, hc and co of dual fuel engine were expounded. through optimization, the smoke emission was utmostly reduced and the emissions of hc and co were within the government restriction
為此,本文通過對各個方案進行詳細比較,選擇了電控多點順序噴射的供氣方案;利用高速lpg噴射閥和自己獨立開發出一套電子控制系統對lpg供氣進行靈活地控制,實現了lpg的定時定量噴射,並把這套裝置應用到中國一拖生產的lr6105q12柴油機上,在對改裝前後的發動機進行大量試驗和分析的基礎上,闡明了負荷、轉速、摻燒比等因素對雙燃料發動機的煙度、 hc 、 co等排放的影響情況,並且通過優化,最大限度地降低了發動機的煙度排放,同時使hc 、 co排放限制在國家標準規定的范圍之內。Intake exhaust valves
進氣和排氣閥With its exclusive patented relief valve design incorporating the " air - in / water - out " principle, it provides substantially improved relief valve discharge performance during the emergency conditions of combined backsiphonage and backpressure with both checks fouled
配置獨特專利技術安全閥結構,採用「氣進/水出」原理,當兩個止回閥被污染並且產生反虹吸和反壓力緊急狀況下,這種原理實實在在改善了安全閥的排泄性能。Typical applications include manifold absolute pressure ( map ), barometric, egr pressure and brake boost
主要用於進氣歧管絕壓、大氣壓力、排氣再循環閥( egr )壓力和制動泵壓力測量。Meanwhile, the air valves make the gleithretter of the air valve open and close automatically with the changing of gas pressure in the air cylinder to finish gas entry and exhaust automatically
同時,氣閥隨著氣缸內氣體壓力的變化而使氣閥的滑片自動開啟和關閉,所以可自動完成進氣、排氣的過程。The condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure
建立了空氣冷卻實驗臺,熱管的加熱方式為電加熱,工質為蒸餾水.在1 1模型上對分離式熱管管內凝結換熱特性、不凝性氣體對凝結換熱的影響及不凝性氣體的擴散規律進行了試驗,得出分離式熱管有一最佳充液率,其值為45 %左右;凝結換熱系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離式熱管的凝結換熱僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性氣體對分離式熱管冷凝段的影響減少.這些結論可用於分離式熱管換熱器的工程設計和控制Abstract : the condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure
文摘:建立了空氣冷卻實驗臺,熱管的加熱方式為電加熱,工質為蒸餾水.在1 1模型上對分離式熱管管內凝結換熱特性、不凝性氣體對凝結換熱的影響及不凝性氣體的擴散規律進行了試驗,得出分離式熱管有一最佳充液率,其值為45 %左右;凝結換熱系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離式熱管的凝結換熱僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性氣體對分離式熱管冷凝段的影響減少.這些結論可用於分離式熱管換熱器的工程設計和控制Pressing - off inlet valve in partial stroke is one of the methods of air - regulating for reciprocating compressor, and it has economic, safe and well - fixing character
部分行程頂開吸氣閥進行排氣量調節是活塞式壓縮機氣量調節方法中的一種,具有經濟、可靠和安裝方便等特點。分享友人