道脈 的英文怎麼說

中文拼音 [dàomài]
道脈 英文
autolyte
  • : Ⅰ名詞(道路) road; way; route; path 2 (水流通過的途徑) channel; course 3 (方向; 方法; 道理) ...
  • : 脈名詞1. (動脈和靜脈的統稱) arteries and veins2. (脈搏的簡稱) pulse 3. (像血管的組織; 連貫成系統的東西) vein
  1. The pulse pneumatic conveying system has been a important transporting method for grain material, because of lower velocity, higher ratio of blend and a littler gas, as well as shattering less materiel, abrasing pipeline and easy recovery

    沖氣力輸送裝置以其低速、高混合比、低耗氣量等一系列持點,並由此帶來的被輸送物料破碎少、管磨損小、產生粉塵少並且易於回收等優點,成為新一代粉粒料氣力輸送設備,並且被廣泛使用。
  2. Chacaltaya is an acclimatization center for climbers preparing to ascend the next - door peak and the club is considering opening a path to the neighboring mountain

    嘉卡塔雅是登山者預備攀登隔壁山峰的高度適應中心,俱樂部正考慮開辟一條通往鄰近山路。
  3. Based on 2m contour of surveyed bathymetry from 1976 to 1999 and mean - high - tidal line distracted from remote sensing images acquired by landsat - 5 tm from 1976 to 2000 respectively, quantitative analysis about alluvion and erosion as well as the relationship between accretion of modern yellow river delta and the water and sediment discharge of yellow river is made, and the results indicate the mean - high - tidal level is more effective than 2m contour of the bathymetry. it is found that the accretion of modem yellow river delta is becoming less and less, what ' s more, erosion is even more than alluvion in some recent years. diaokou promontory has been eroded seriously since yellow river changed its course in1976

    以一般高潮線反映現代黃河三角洲沖淤演變時,從1976年黃河改清水溝流路入海到2000年,整個黃洞三角洲凈造陸201 . 5km ~ 2 ,淤積有逐漸變慢的趨勢,甚至出現凈蝕退的年份;刁口河嘴大量蝕退,蝕退速率開始快速,后來逐漸變慢;清水溝河嘴大量淤積,淤積速率開始迅速,后來逐漸變慢,甚至出現凈蝕退;清水溝河嘴南側到支溝一段岸線與刁口河嘴以西到灣灣溝一段岸線基本穩定。
  4. The tall danger crowd of third hepatitis is the person that point to to blood often is exposed outside alvine path, the person that if medicaments is abused inside hemophiliac, vein, become addiction, blood is dialytic patient of surgery of patient, marrow and kidney transplant patient, heart and the patient that often inject via the skin

    丙型肝炎的高危人群是指經常腸外暴露血液者,如血友病患者、靜內濫用藥物成癮者、血液透析患者、骨髓和腎移植患者、心外科患者以及經常經皮注射的患者。
  5. Intravenous digital subtraction angiography

    注射數字減影血管鏡術
  6. Therefore, the crucial factor of technology of nucleus - detection is nuclear spectrum data collecting system whose core is the multi - channel analyzer ( mca )

    所以以多道脈沖幅度分析器為核心的核能譜數據採集系統,是核輻射探測技術的關鍵。
  7. As compared with multi - channel analyzer, platform of microcomputer consumes much more energy, thereby, it will follow a rational line to be research and developing orientation of nuclear spectrum apparatus to choose new pattern platform of microcomputer of low power and develop tiny pattern and low power nuclear spectrum apparatus

    對于基於臺式機和筆記本平臺的多道脈沖幅度分析器,微機平臺功耗很大。因此選用新型低功耗微機平臺,開發小型、低功耗的核能譜儀,成為今後核能譜儀的研究發展方向。
  8. Measuring technology of multi - channel is the foundation of matter composition and radioactivity verifying by way of nuclear methods. the dissertation aims at developing tendency of measuring technology of multi - channel nuclear energy spectrum, combining the characteristics of field working, focusing on systematically reseach on some key techniques such as the design of multi - channel analyzer ( mca ) and apparatus, with a view to resolve defects exsisting in current portable apparatus

    論文瞄準國內外多核能譜測量技術的發展趨勢,結合現場工作的特點,針對目前現場多核能譜測量儀器中存在的諸如儀器功耗、重量、體積偏大,不便於現場操作等問題,在多道脈沖幅度分析器以及儀器的單片機機化等方面作了較為系統的研究。
  9. Moreover because the detector output pulse signal base is very broad, its scope has a long tail, it can not adapt to request of the multichannel pulse amplitude analyzer

    另外由於探測器輸出沖信號底部較寬,脫尾嚴重,不能滿足多道脈沖幅度分析器的要求。
  10. The dissertation discusses about field multi - channel nuclear data collecting system based on mcu in detail. the data collecting system adopts mcu ( micro - control units ) at89c55 as controlling core, applying high speed and low power adcs ( analog - to - digital converters ) cmos chip max 191 and 320x240 matrix graphic lcd ( liquid crystal display )

    該系統在硬體上以單片機at89c55為控制核心,以高速低功耗的a d晶元max191作為多道脈沖幅度分析器的模數轉換器件,以320 240點陣圖形液晶顯示屏作為系統的顯示器,根據初步的性能測試,系統已經達到預期的設計目標。
  11. The common detector output pulse signal scope is several dozens millivolts, but the multichannel pulse analyzer input pulse amplitude request is 1 - 15v, therefore the pulse linear amplifier must have the certain voltage gain, about ten times to several times

    一般探測器輸出沖信號幅度為幾十毫伏,而多道脈沖幅度分析器輸入沖幅度要求為1 - 10v ,所以沖線性放大器必須具有一定的電壓放大增益,為數倍到上百倍。
  12. Utilizing the pulse neutron generator working with controlled circuit and time amplitude converter, the ash content in coal is measured, and we provides a safe and on line methods

    通過該思路,利用沖中子發生器,控制電路,多道脈沖幅度分析器對煤中灰份的含量進行了測量,提出了一種實時、安全的快速檢測方法。
  13. Using it, time amplitude converter and pulse neutron generator, the y spectra of 14mev pulse neutrons is measured. utilizing the time difference of several different reactions about the interaction of neutrons and nucleus, the whole spectra and the capture spectra are measured. a method that uses double gate subtracting background to gain the fast neutrons " inelastic scattering y spectra is introduced

    研製了一種線性門電路,介紹了它與沖中子發生器、多道脈沖幅度分析器配合,進行14mev沖中子譜的測量,利用中子和原子核相互作用的幾種反應在時間上的差異,測量了總譜和俘獲譜,採用雙門減本底方法得到了快中子非彈性散射譜。
  14. The thesis introduces the hardware and software design skills of a new type multi - channel pulse amplitude analyzer ( mca ) based on fpga chip and enhanced parallel port ( epp ) interface

    本文從硬體和軟體兩方面詳細地介紹了以fpga晶元為控制核心的基於epp介面的新型多道脈沖幅度分析儀的研製過程。
  15. The pulse neutron generator " s delaying time are measured by the time - amplitude converter and multichannel pulse amplitude analyzer. according to these times, the linear gate circuit " s opening time can be adjusted

    用它和多道脈沖幅度分析器配合測量沖中子發生器發射中子的滯后時間,據此調整線性門電路的開門時間。
  16. The specetrum data - collecting subsystem is controlled by a single - chip micro - controller at89c52, including 1024 - channel pulse - height analyzer and rs232c serial communication interface

    譜數據採集子系統由單片微控制器at89c52控制,包括1024道脈沖幅度分析器和rs232c串列通訊介面。
  17. In the foreign country, neutron induced prompt gamma - ray analysis ? ipga was used to analyze the elements in substance and has been used in real production and industry " s analysis on line now. in our country, the method has been studied and used from 70 " s and has been more and more perfect. however, the neutron source they used is the isotope source

    在國外,早已開始採用中子感生瞬發射線分析法( nipga )對物質進行元素分析,如今這種方法已經應用於實際生產和工業在線分析,國內在八十年代也開始研究、應用這種方法,如今已日趨完善,然而,他們使用的中子源絕大多數仍然是同位素中子源,做為一種可行性實驗方法研究,我們採用沖中子發生器做為中子源,自行研製的線性門電路和多道脈沖幅度分析器相配合,獲取非彈性散射和俘獲譜,對物質進行元素分析。
  18. Multi - channel pulse height analyzer

    道脈沖高度分析儀
  19. Multichannel pulse height analyzers - main characteristics, technical requirements and test methods

    道脈沖幅度分析器主要性能技術要求和測試方法
  20. Our research is mainly about visual multi - channel pulse signal generator ( virtual instrument )

    本課題的主要研究重點是可視化、多通道脈沖信號發生器(虛擬儀器)的研製與開發。
分享友人