量電阻橋 的英文怎麼說

中文拼音 [liángdiànqiáo]
量電阻橋 英文
measuring bridge
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • : 名詞1. (橋梁) bridge 2. (姓氏) a surname
  • 電阻 : (物質阻礙電流通過的性質) resistance; electric resistance (電路中兩點間在一定壓力下決定電流強度...
  1. The main work and conclusion for this paper is as following : according to the flashover test results of several kinds of iced insulators under positive voltage and negative voltage, this paper obtained : for the single porcelain insulator, the single glass insulator and the composite insulator bridged completely by icicle, the metal cathode ' s strong ability of emission electron is the primary reason that results in the lower negative flashover voltage ; the position difference of the high resistance district in method anode side results in that porcelain insulator cluster and glass insulator cluster have an evident effect of polarity ; when less ice and no icicle at the brim of the sheds, due to numerous non - polar arcs on the composite surface, the effects of polarity of composite insulator was lost using the test method of the average flashover voltage in the freezing period, dc flashover performances were investigated of several insulators with some typical structures and different material

    本文的主要工作和結論如下:在人工氣候室內,根據不同覆冰絕緣子正、負極性下的閃絡試驗結果,得出負極性弧金屬陰極的強子發射能力造成了單片瓷、玻璃絕緣子及被冰凌接的合成絕緣子有較低負極性冰閃壓;正極性弧金屬陽極側產生高區所處位置的差異使得瓷和玻璃絕緣子串具有明顯的極性效應;覆冰較少時,合成絕緣子表面出現數較多的非極性弧使合成絕緣子無極性效應。利用覆冰期內平均閃絡壓的試驗方法,對不同材質和結構的絕緣子在覆冰、低氣壓和污穢共存環境中的直流閃絡特性進行了研究。試驗結果表明,直流平均閃絡壓隨著海拔的升高、覆冰的增加以及污穢度的增加而降低,且其特徵指數與絕緣子結構、覆冰、覆冰狀態、污穢度等有關。
  2. A resolution method in software is applied to calibrate zero point and full scale of the circuit. software approach to nonlinear correction for sensor and circuit is presented. therefore system error is eliminated, and measurement accuracy of temperature is improved. the signal of acidity electrode is detected by a differential amplifier circuit, which consists of operational amplifiers tlc2254 with high input impedance and low drift

    採用路和單運放差動放大路對溫度傳感器信號檢測放大,軟體校正溫度傳感器和測路的非線性,軟體校準測路的零點和滿度,消除測路的系統誤差,提高補償溫度的測精度;採用高、低漂移運放tlc2254組成高差動放大路用於酸度極信號測
  3. An experimental study of the measurement of resistae by applying unequilibrium electric bridge

    應用非平衡實驗的研究
  4. According to the principles of unequilibrium electric bridge, this paper analyses the work features of the three bridge types and based on experiments, shows how to select the bridge types and parametes. to reduce the non - linear errors and avoid centain unusual circumstances in the measurement

    從非平衡原理出發,分析了3種式的工作特性,並通過實例說明如何選取式與參數,以減少測的非線性誤差及避免一些異常情況。
  5. 2, design a structure makes the liner output higher to 160mv with a liner input about 150 in bridge of spin - valve gmr. in comparison of some typical mr angular sensors it ' s output make a great progress

    2 ,設計了一種結構使自旋閥gmr晶元組成的路輸出壓信號線性區達到約150 ,輸出幅度達到了160mv ;相比一些典型的磁非接觸式角度傳感器,程獲得了可觀的擴展。
  6. Dc bridges for measuring resistance ; amendment 2

    用直流.第2次修訂
  7. D. c. bridges for measuring resistance

    用直流
  8. They use a bridge to measure the impedance of the transducer

    他們用來測傳感器的
  9. In this paper, a kind of improved practical active linear bridge circuit with platinum resistor is used to eliminate the error mentioned above, and the precise temperature measurement can be made

    本文採用鉑改進型實用有源線性化路克服了上述誤差,實現了高精度的溫度測
  10. In temperature measurement of the thermal resistor, the nonlinearity of thermal resistor, lead resistor and unbalanced bridge may produce errors

    摘要熱溫度測中,熱的非線性、不平衡的非線性及引線都會給測帶來誤差。
  11. D. c. bridge for measuring resistance

    用的直流
分享友人