門開口調節器 的英文怎麼說

中文拼音 [ménkāikǒudiàojié]
門開口調節器 英文
door adjuster
  • : Ⅰ名詞1 (房屋、車船等的出入口 ) entrance; exit; door; gate 2 (形狀或作用像門的東西) switch; va...
  • : Ⅰ名詞1 (人或動物進飲食的器官; 嘴) mouth 2 (容器通外面的地方) mouth; rim 3 (出入通過的地方) ...
  • 調 : Ⅰ動詞1 (配合得均勻合適) harmonize; suit well; fit in perfectly 2 (使配合得均勻合適) mix; adju...
  • : 節構詞成分。
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 調節器 : regulator; adjuster; governor; controller; conditioner; actuator; phaser
  • 調節 : regulate; adjust; monitor; measure; take care of; condition; regulation; adjustment; conditioning...
  1. Whole scheme of frame design of test - bed is proposed as : the host fanner supply the firebox the once and twice air required by diesel oil ' s burning and the cooling air ; the export parameter of the test - bed is varied by the adjust of the flux of air and diesel oil. and the air flux is varied by adjusting the rev of the fanner adjusted by transducer and the corner of the fan inlet adjusted by step motor. the quantity of oil is varied by adjusting the oil valve adjusted by step motor ; the measurement of the air flux in the test - bed adopts the method of fanner dynamics performance test in the nation criterion

    確立了實驗臺結構設計方案:主風機為燃燒提供燃燒所需的一次、二次進風量及冷卻風量;利用變頻調主風機轉速、用步進電機調度來調風量,用步進電機調回油閥度來調供油量,從而實現對模擬實驗臺出煙氣熱流量的調;實驗臺的流量測量採用風機動力性能測試標準中測流量方法等。
  2. Whole scheme of frame design of testing flat is proposed as : the host fanner supply the air required by flamer ’ s burning and cooling, the export parameter of the flat varies by different rotate speed of the fanner 、 angle of the fan inlet and the quantity of oil, the measurement of flow in the testing flat adopts the method of fanner dynamics performance test in the nation criterion

    確立了實驗臺結構設計方案:主風機為燃燒提供燃燒所需的一次、二次進風量及冷卻風量;模擬實驗臺出煙氣熱流量是通過調風機的轉速、風度及燃油量來改變;實驗臺的流量測量採用風機動力性能測試標準中流量方法等。
  3. Directing against state of affairs at present, such as margin of type - selection parameters being selected comparatively large during design stage of air fans for boilers in thermal power plants, the opening degree of air fans in operation being often smaller ( for adjustment of inlet regulator ) or operation at lower revolution speed ( for speed - regulating operation mode ), and efficiency of air fans being lower etc., factors and corresponding measures having to pay attention in margin selection of air fan ' s parameters have been put forward through analysing practical example of retrofitting forced draft fans in one power plant, playing certain positive role for energy - saving and benefit - increasing in power plants

    摘要針對目前火力發電廠鍋爐風機在設計選型時參數裕量選取較大,運行時風度較小(對入調調)或低轉速運行(調速運行方式) ,風機效率較低的狀況,通過對某電廠送風機改造實例的分析,提出了在風機參數選擇中的裕量選取需要注意的因素及相關對策,對電廠的能增效有一定的積極作用。
分享友人