  1. This article has studied the deficiency and shortcoming of various kinds of methods of the parameter measurement of transmission line at present, proposed the measurement under operation on the basis of gps, researched gps application way and error that may appear in the power system synchronal sampling, put forward the parameter computing technology based on the information of both sides of transmission line, which solved some problems that exist in the parameter measurement, especially the problem that exist in the zero - sequence parameter measurement of transmission line with mutual inductance

    本文研究了目前輸參數測量的各種方法,分析了其中存在的不足和缺點,提出了基於gps的輸參數在線測量方法,研究分析了gps在力系統同步采樣中的應用方以及可能出現的誤,在同步采樣的基礎上提出了基於雙端信息的線參數計算方法,較好地解決了輸參數測量中存在的一些問題,尤其是多回互感線序參數測量困難的問題。
  2. Become a kind of new electronics circuit - current - mode circuit. it is replacing the traditional design method of the voltage - mode in the high frequency high - speed signal processing realm 。 this thesis mainly discussed the modified second - generation current conveyors based on the current - mode kinds of new cuicuit components, they are stronger modified standard current - mode parts in fuctions on this foundation. mainly including the modified differential difference current conveyor ( mddccii ) 、 the fully balanced second generation current conveyor ( fbccii ) 、 ( full balances ) four - terminal floating nullor ( fbftfn ) and the current differencing buffered amplifier ( cdba ), they are all function very strong standard current - mode parts, they all can provide some circuit functions of better than general operation amplifier, because they have the voltage importation and the current importation, therefore use it since can carry out the voltage - mode signal processing circuit expediently, can also carry out the current - mode signal processing circuit expediently, and have to increase the benefit bandwidth to accumulate more widely than the voltage - mode, but have their advantages more according to the current - mode filter of the modified current conveyor, because it constitutes in brief, the filter wave function is stronger and they are better than in general use operation amplifier of many advantages, be easy to composing for example 、 high speed 、 frequency bandwidth 、 the power supply voltage requests low 、 consume small, the impedance is different from etc. advantages, otherwise they have biggish dynamic range, and flexible circuit synthesize, so they are the best active parts

    從第二代流傳輸器ccii入手,重點研究了以下幾種改進型的第二代流傳輸器:改進的流傳輸器mddccii 、全平衡第二代流傳輸器fbccii 、多輸出四端浮地器ftfn 、全平衡四端浮地器fbftfn 、分緩沖放大器cdba的結構及其模型。然後在此基礎上系統地研究了基於這幾種改進型的第二代流傳輸器的濾波器的設計方法,主要方法和結果如下:利用mddccii設計了連續時間流模低通、帶通濾波器;流模跳耦結構考爾低通濾波器;利用fbccii設計了帶通二階節濾波器及流模雙二階通用濾波器;設計了基於多輸出端ftfn的流模二階通用濾波器;通過數字化開關選擇的基於fbftfn的流模通用濾波器;設計了基於最少個數流緩沖放大器(兩個cdba )的多功能通用流模濾波器及其在非理想因素情況下分析。設計濾波器的主要方法是採用級聯設計、運算模擬(信號流圖法)和反饋設計(跳耦法) 。
  3. And to the electric capacity type voltage mutual inductor, because it compares with electromagnetic type voltage mutual inductor, transient state its bad to respond characteristic, as circuit when making the short circuit two times trouble, the voltage two times delays dropping to zero while needing to pass certain one

    而對于壓互感器,由於它與壓互感器相比,其瞬態響應特性比較,當線故障而使二次短時,二次壓需經過一定的時延後才能下降到
  4. By study, we can know that when one - phase ground fault happens on the line, more far the fault location is from where relays place, more less is the difference of the two zero sequence currents, while hen one - phase ground fault happens on the other line, more far the fault location is from where relays place, more is the difference of the two zero sequence currents

    研究表明,當本回線發生單相接地短時,在通過公計算得出的一特定值為正時,離保護安裝處越遠,本回線流與非故障線流相位值越小;當另一回線發生單相接地短時,離保護安裝處越遠,本回線流與故障線流相位值越大,該值為負時則反之。