靜態補償 的英文怎麼說

中文拼音 [jìngtàicháng]
靜態補償 英文
static comp
  • : Ⅰ形容詞1. (安定不動; 平靜) still; calm; motionless 2. (沒有聲響; 清靜) silent; quiet Ⅱ名詞(姓氏) a surname
  • : 名詞1. (形狀; 狀態) form; condition; appearance 2. [物理學] (物質結構的狀態或階段) state 3. [語言學] (一種語法范疇) voice
  • : Ⅰ動詞1 (修理; 修補) repair; mend; patch 2 (補充; 補足;填補) fill up; add supplement; supply; ...
  • : 動詞1. (歸還; 抵補) repay; compensate for 2. (滿足) meet; fulfil
  • 靜態 : [物理學] static state; quiescent condition; steady state; statics; dead level; akinesis; akynesis...
  • 補償 : compensate; make up; make up for; make it up to sb. ; make sth. good; compensation; offset
  1. Guide for static var compensator field tests

    變量器區域試驗的指南
  2. Aiming at the compensation benefits calculation combined with development layout of the yellow river mainstream cascades is now taken into account the dynamic characteristic of different level years, the compensation benefit simulation model of the yellow river mainstream cascade reservoirs is adopted to calculate the power generation compensation benefits of the yellow river upstream run - of - river power stations in three level years of 2000, 2010 and 2020

    摘要針對以往效益的研究都是計算而言,本文結合不同水平年黃河幹流梯級的滾動開發規劃,考慮不同年代效益的動特性,採用黃河幹流梯級水庫效益的模擬模型,計算了2000 、 2010以及2020三個水平年黃河上游徑流式梯級電站的發電效益。
  3. 5 ) the system ' s sensitivity and snr can be improved by the method of balancing the standing capacitance using dc offset compensation

    採用直流反饋的方法消除電容傳感器極板間的電容,提高了系統的解析度和信噪比。
  4. Among which regulation monitoring would give some prospective information about the solvency of an insurance company ; static and dynamic regulation are the main methods of solvency regulation, and the guaranty fund is the final safeguard to the insureds of those insurance companies which have no solvency

    其中預警機制是對保險公司付能力的事前預測,重在為監管部門提供關于保險公司付能力狀況的信息;監管和動監管是對保險公司成立和經營過程中付能力的具體監管方法;而保險保障基金是對出現付能力不足問題的保險公司的最後救。
  5. With the development of the electric power system, static - state reactive power compensators ca n ' t have met the requirements of the actual production and operation, and the trend to the fast and dynamic compensation for reactive power become greater and greater. since ertan hydroplant and 500kv transmission systems in sichuan power system have been operated, many power plants of load center are forced to halt during the high - water period, because the great deal of power is transmitted to far - distance load center. thus the load center loses voltage sustentation and the level of the system stabilization is debased greatly

    四川電網的二灘水電站和500kv輸變電系統投入運行后,由於二灘水電站的大量電力遠距離輸送至負荷中心,迫使負荷中心的火電機組在豐水期大量停機,使負荷中心失去電壓支撐,大大降低了電網的電壓穩定水平;同時,因為四川電網中的無功裝置全為無功電容器(或電抗器) ,這些設備只能在系統正常運行狀下起到無功和電壓支撐的作用,而在電網出現事故時,不但不能起到電壓支撐作用,反而會促使電網電壓崩潰事故的發生。
  6. The principle and the mechanical structure of the air - gap inductance - type transducer are analyzed in this article, and the static parameters are calibrated. dynamic calibration is applied to air - gap inductance - type transducer which is not good in dynamic capability, to obtain the dynamic parameters of the transducer and its measuring circuit. based on the result of the dynamic calibration, the transducer and its serving circuit are modeled so that the method of how to improve the dynamic performance can be found

    本文對現有氣隙式電感傳感器在原理和機械結構上作了深入的分析,對其參數進行了標定;並且針對常規電感傳感器動響應低,不宜用於快速動測量的缺點,引入測試系統動力學的思想,設計了一套動校準系統,對現有傳感器進行多次動校準,根據動校準的實驗結果對現有傳感器建立數學模型,得到現有傳感器的動特性;在此基礎上,根據磨床工件在線檢測的要求,設計一個硬體系統來提高整個測試系統的動特性。
  7. Power electronics for electrical transmission and distribution systems - testing of thyristors valves for static var compensators

    電力輸送和配電系統用功率電子設備.var器用閘流晶體管試驗
  8. On the basis of theoretical analysis and numerical calculations using matlab language combined with a real instance, it is indicated that the improper electrical parameter coordination caused by the abundance of power cable lines result in fundamental frequency current resonance, in addition, the countermeasures based on svc to solve the problem are put forward

    文中結合某變電站異常運行狀實例,在理論分析和matlab語言數值計算的基礎上,指出由於電纜的大量使用導致了該系統參數配合不當,從而誘發了基波電流諧振,並提出裝設靜態補償器以防範該類諧振。
  9. Abstract : the attitude error performance of electrostatic gyro should be understood and the relevant error equations must be set up in order to ensure the navigation precision of esgm. the relation between the navigation errors and the attitude errors of gyro was derived by use of spherical triangle. the simulation results show that the temporal performances of the longitudinal and distance errors which come from the initial alignment errors are periodically variational. they also show that the longitudinal and distance errors resulted from gyro drifts are not convergent in time. thus, the effects of initial alignment errors and gyro drifts can not be neglected and must be estimated and compensated

    文摘:為了保證電監控器的導航定位精度,需要了解電陀螺的姿誤差特性,建立相應的誤差方程.本文採用球面三角形原理推導了導航定位誤差與陀螺姿誤差的關系式.模擬結果表明,由初始定向誤差引起的經度誤差和距離誤差的時間特性是周期變化的;由陀螺漂移引起的經度誤差和距離誤差是隨時間發散的.因此,初始定向誤差和陀螺漂移的影響不能忽略,必須對其進行估計和
  10. By the way, a displaying system and a communicating system is added. this dissertation is divided into four chapters altogether : chapter one is the introduction, introducing the hore component and its important characteristic and putting forward the basic task ; chapter two introduce the principle of the auto - tracking system and respective parts of the auto - tracking system ; chapter three introduce the applications of auto - tracking system under static condition and dynamic condition and give out the experiment results ; chapter four introduced the displaying system, communicating system and the applicability of the auto - tracking system to other sensors

    本文共分為五章:第一章緒論中,介紹了霍爾元件及其一些重要特性,並提出了測量系統的基本方案;第二章詳細介紹了測量系統各部分的構成及原理,特別是對直流通道、溫度模塊和音圈電機為核心的隨動機構的論述;第三章介紹了實際系統在測量和動測量兩種模式下的應用及實驗結果;第四章介紹了系統的顯示功能和遠程通信功能並討論了系統對其它傳感器的適用性。
  11. So this paper analyzed the running state by taking account of power over - voltage, resonance over - voltage and voltage flash, and propounded the strategy that voltage flash were controlled by using static var compensator ( svc )

    本文從影響配電網的三個因素:工頻過電壓、諧振過電壓以及電壓閃變入手,分析了現代配電網的運行狀。並提出用止無功器( svc )抑制電壓閃變的控制策略。
  12. This modeling method is applicable to most of facts and hvdc devices, not only to those devices including thyristor - controlled reactor ( tcr ), such as thyristor - controlled series capacitor ( tcsc ) and static var compensator ( svc ), but also to those devices including converter bridge, such as hvdc device and static synchronous compenstor ( statcom ), etc. it deduces the mathematical models of tcsc, hvdc, svc and statcom devices with the proposed method

    該方法能適用於大多數facts裝置和hvdc裝置,不僅可用於含有晶閘管可控電抗器( tcr )元件的裝置如可控串聯電容( tcsc ) 、止無功器( svc )等的建模,也可用於含換流橋的裝置如hvdc裝置、止同步器( statcom )等的建模。本論文採用動相量法建立了tcsc 、 svc 、 hvdc及statcom裝置的數學模型。
  13. The application of still dynamic reactive compensating gear

    止型動無功裝置的應用
  14. A novel design of static var compensator based on pwm technique

    技術的止型動無功裝置設計
  15. Therefore, aiming at the existent static and dynamic error of fcs sensor, the sensor characteristic compensation subunit is designed in the environment of labview using vi technique. the sensor signal disposal platform is also developed to realize the time domain measurement, frequency domain analysis, long - distance transfer and network release, etc. firstly, the static characteristic and nonlinear error of the sensor are analyzed

    為此,本文針對飛控系統傳感器存在的和動誤差,利用虛擬儀器技術在labview環境下設計了傳感器性能環節,開發了傳感器信號處理平臺,對信號進行時域測量、頻譜分析、小波消噪、遠程傳輸和網路發布等。
  16. At present, the research on compensating reactive power using static compensation device is one of the most active areas in power electronics subject

    利用止無功裝置實現動無功功率的研究是目前電力電子學科中比較活躍的研究領域之一。
  17. A reactive power compensation method for enhancing extensive power system steady state voltage stability

    提高大規模電力系統電壓穩定性的無功方法
  18. It emphases the selection of secondary voltage of the step - down transformer, the control and protection of thyristor, the calculation of compensation capability and group capability, the technique of cross - zero switched on / off capacitors or reactor, the solution of avoiding possible resonance in switching on / off groups of capacitors or reactor and the measure of the best time to switch ( including the design of the computer survey and control system, instrument deliver system, delay operate and protect system ). although thyristor as a no - contact switch can avoid almost the problem of contact switch with contact, it can not solve the over - voltage, over - current and transient process itself as switching on / off capacitors or reactor. so we must develop a set of thyristor - switched control and protect system with great reliability so that it can realize of cross - zero switching on / off capacitors or reactor at any time

    晶閘管具有過零、動作快速的特點,本研究以晶閘管為電容器和電抗器的分組投切開關,重點研究了協調變壓器二次電壓的選擇、晶閘管觸發控制及保護、動容量及分組容量的計算確定、過零投切電容器和電抗器技術的實現、以及分組投切電容器和電抗器可能發生諧振的處理計算方法,給出實現最佳投切選擇方法(測控系統、儀表變送系統、操作和保護系統的設計步驟) ,研製了一套高可靠性晶閘管觸發控制及保護系統,實現對無功的止可調
  19. Modified mrac scheme with switched adaptive law and static compensator

    具有切換自適應律和靜態補償器的模型參考自適應控制
  20. The specifications of low - voltage reactive power steady compensation equipments

    低壓無功功率靜態補償裝置總技術條件
分享友人