額定負荷運行 的英文怎麼說

中文拼音 [édìngyùnháng]
額定負荷運行 英文
rated load operation
  • : 名詞1 (額頭) forehead:寬額 a broad forehead2 (牌匾) a horizontal tablet 3 (規定的數目) a sp...
  • : Ⅰ形容詞1 (平靜; 穩定) calm; stable 2 (已經確定的; 不改變的) fixed; settled; established Ⅱ動詞...
  • : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
  • : 荷名詞(蓮) lotus
  • : Ⅰ動詞1 (物體位置不斷變化) move; revolve 2 (搬運; 運輸) carry; transport 3 (運用) use; wield...
  • : 行Ⅰ名詞1 (行列) line; row 2 (排行) seniority among brothers and sisters:你行幾? 我行三。where...
  • 負荷 : [電學] load; charge; weight
  • 運行 : move; be in motion; run; working; machine run; operation; corotation; propulsion (影片)
  1. The test shall demonstrate to the satisfaction of the owner that the equipment meets all specified performance criteria, is properly installed and anchored, and operates smoothly throughout the specified speed range without exceeding the full load amperage rating of the motor or excessive motor heating

    測試應該讓用戶滿意,證明這些設備符合所有規的性能標準,經過正確的安裝和錨固,在轉速范圍內平穩,沒有超過電機的滿轉電流安培數,或發生電機過熱。
  2. This article aims at the boiler ' s problems in operation : 1 ) under nominal load, the smoke temperature at the outlet of hearth reaches 1200, far more exceeds 1050 the original designed temperature. this will always result in slag inside boiler and the temperature of overheater ' s pipe superheat, so that boiler cannot take nominal load and all these influence boiler ' s nomal operation heavily, 2 ) this article also studied the reason why the assistant oil becoming necessary when coal changes. during the nomal operation, many factors ( makeup of combustor and its disposal, smirch and encrust of water wall, excessive air coefficient, temperature of primary air, coal type and density of coal dust ) can deviate the designed working conditions, then affect the boiler ' s nomal operation

    本文針對該鍋爐在實際中存在的問題:在下,爐膛出口超溫、低溫段過熱器前煙溫高達936 ,遠遠超過815的設計值;噴燃器四周水冷壁結焦嚴重,過熱器管壁溫度超標,無法帶上;甚至有時因燃煤質量的變化,必須投油助燃的嚴重情況進了分析研究。在實際生產過程中,燃燒器的結構、布置,水冷壁的粘污、結垢,過剩空氣系數、一次風溫、煤種及其濃度變化等許多因素都會偏離鍋爐的設計工況,從而影響爐內的傳熱和燃燒,造成爐膛出口超溫、水冷壁結渣等問題。
  3. In view of this situation this article has conducted research to the design of metallurgy auxiliary biography with the frequency conversion table electrical machinery first multianalysis to the frequency changer and the frequency conversion table electrical machinery movement characteristic is carried out, the voltage waveform harmonious which the frequency changer outputs is big, attacks in a big way, and the voltage climbing rate reaches as high as 6600v / mu s which is 20 times ordinary sine alternating voltage, the rolling mill auxiliary biography table set the extremely strict request to the electrical machinery ; its movement frequency is very low, rate frequency in 8 - 20hz ; the velocity modulation scope is wide, the lowest movement frequency lowers to 1hz, and the starting number of times is quite frequently, each hour reaches as high as 600 - 800 time, the impact shoulders in a big way, the overload capacity request is high

    針對這一情況本文對冶金輔傳用變頻輥道電機的設計進了系統研究。首先對變頻器和變頻輥道電機的特性進詳細分析,變頻器輸出的電壓波形諧波大,沖擊大,電壓上升率高達6600v / s ,是普通正弦交流電壓的20倍;軋機輔傳輥道對電機提出了十分嚴格的要求:其頻率很低,頻率在8 - 20hz ;調速范圍寬,最低頻率低到0 . 5hz ,起動次數相當頻繁,每小時高達600 - 800次,沖擊大,過載能力要求較高。
  4. The propeller may be overloaded which caused by some reasons when ship has been serviced for a period of time. as a result, the rated revolution of the engine cannot be achieved, or the engine may be on overloaded operation condition. it will not be in the optimum matching between the propeller and the engine

    船舶在使用過程中,常因各種因素使螺旋槳出現過「重」的現象,主機達不到轉速或超轉,槳機不能處于最佳匹配;另外當船舶人為地降速航時,主機處在半情況下工作,如果轉速下降太多,使得主機的工作條件變壞,容易引起主機部件的損壞。
  5. Over load working of transformers are guided by iec905 loading guide for dry type power transformers

    按照iec905 《乾式電力變壓器載導則》 ,是指導變壓器過(超銘牌值)
  6. The main problems existed in the measured buildings conclude : low energy efficiency plants, low eer when the cooling load decreased during the night period in hotels, bad management, dissatisfied indoor air quality, low efficient water system and so on. if we can avoid these problems, a lot of energy can be saved

    重慶市公共建築主要存在的問題有:設備效率達不到值,冷水機組冷量配備過大,酒店在夜間低時空調系統能效比( eer )很低,室內環境很不令人滿意,水系統輸送效率低下,跑冒滴漏現象嚴重,管理混亂等。
  7. To put into operation a large amount of non - linear load, make in harmony wave of rural power grids serious becoming in pollution, pass to rural local electric wire netting main in harmony analysis of wave source, put forward in order to restrain from insert rural power grids in harmony wave source voltage total in harmony wave distortion rate and the containing rate change last device number pulsating for increase of goal, increase the pulse of the current change device and install light specified value electricity active wave filter mix with passive wave filter near the harmonics source to control the wave in harmony

    摘要大量非線性的投,使農村電網的諧波污染日趨嚴重,通過對農村地方電網主要諧波源的分析,最終提出了以限制接入農村電網的諧波源的電壓總諧波畸變率和各次諧波電壓含有率為目標的增加換流裝置脈動數,以及在諧波源附近裝設小值的電力有源濾波器配以無源濾波器的混合型電力濾波方式,以進諧波治理。
  8. Under different load, when we apply this software to any time, region and cooling way, we can get the hottest spot increment and aging rating. to manufactory, the software means sounder thermal design, which will meet the load, putted forward by user, while to user, the software equal to a master who can help them decide the capacity rating of the transformer, which will fit the load. by using the software, the potential danger and the waste, caused by unfit load choice may be avoided

    研究開發了計算乾式電力變壓器載能力的計算軟體,可對于各種絕緣結構,各種冷卻方式和任一地區、任一時間下的變壓器在不同下的最熱點溫升絕緣老化率進分析和計算,同時利用該軟體製造廠可以依據用戶提出的載量給出相應的熱設計方案,用戶可根據載情況利用軟體計算所需變壓器的容量,避免容量選擇不當造成隱患和浪費。
  9. On asian - european marine routes refrigeration systems are placed in 40 - 90 % rating heat load for a bng period of time and the energy is wasted considerably

    亞-歐、亞-美航線上冷藏集裝箱製冷系統長期處在的40 90下,能量浪費極其可觀。
分享友人