air coil 中文意思是什麼

air coil 解釋
空氣冷卻蛇管
  • air : n 1 空氣,大氣。2 天空,空中。3 微風,和風。4 態度,樣子,風度,氣派;〈pl 〉高傲的架子。5 傳播,...
  • coil : vt vi 卷,盤繞,(把…)盤[卷]成一圈 (up)。n 1 (一)卷,(一)盤,(一)圈。2 螺旋管,蛇管。3 ...
  1. Shanghai air conditioning copper tube factory, one of the four divisions of shanghai zhongxin copper tube industry co., ltd. is a manufacturer for coppertubes in straight length, level wound coil and pancake coil used in fieldsof air conditioning, refigeration, water - heater, heating - system service

    上海中鑫銅管工業有限公司所屬的空調管廠,是專門生產直條管、水平纏繞空調管、扁平蚊香盤狀管和內螺紋銅管的企業,產品廣泛適用於空調及配件、冰箱、冷藏、熱水器、集熱供暖等行業。
  2. The reheat coil adjusts supply air temperature to offset building heat losses due to transmission.

    再熱盤管調節送風溫度,以補償因傳熱造成的建築熱損失。
  3. The process air conditioned rooms adopt equipment room dedicated air cooled air conditioning units, and the comfort air conditioned rooms adopt fan - coil unit plus fresh air system

    工藝性空調房間主要採用了風冷式機房專用空調機組,舒適性空調房間採用風機盤管加新風系統。
  4. Air cooling coil

    氣冷盤管
  5. Effect of air cooled coil fan pre - start on the refrigeration system dynamics during the reverse - cycle defrost of an air - source heat pump chiller

    風機提前啟動對風冷熱泵冷熱水機組除霜的影響
  6. If a coil has no metal core it has an air core.

    如果線圈沒有金屬芯子,它就有一個空氣芯子。
  7. Air coil winding machine for self bonding wire

    自融線空心線圈繞線機
  8. The respiratory infection wards adopt the air conditioning system of fresh air plus dry fan coil units with high residual pressure and high efficiency filter, the outpatient department and the clinical laboratory all adopt independent direct all - fresh air air conditioning system

    摘要呼吸道傳染病房採用新風加帶高效過濾器的高餘壓乾式風機盤管機組的空調形式,呼吸道門診、檢驗科均採用獨立設置的直流式全新風空調系統。
  9. Air dried coil varnish

    自干繞組清漆
  10. Research on a new air conditioning system of evaporative cooling and fan - coil unit in dry coil

    乾式風機盤管半集中式空調系統探討
  11. Takes several energy saving measures for air conditioning system, nick a large capacity centrifugal chillers working with variable frequency nil capacity chillers, variable frequency and variable flow control on secondary pump water systems, cooling tower for four - pipe water system in winter, fan - coil unit for commercial peripheral zones aid all - air systems for interior zones, variable frequency control on supply and exhaust air fain, enthalpy control on fresh air cooling in winter and intermediate season

    採用了多項空調節能措施:大冷量離心冷水機組搭配變頻小冷量機組,二次泵變頻變流量空調水系統,四管制風機盤管冬季用冷卻塔換冷供冷設計,商業外區風機盤管、內區全空氣空調系統,送風機、排風機變頻控制,過渡季、冬季利用室外新風通風降溫的焓值控制設計。
  12. Other equipment : four 20 top ' s bridge cranes, two 10 ton ' s bridge cranes, six 5 top ' s bridge cranes, one 20 top ' s handjack, one 8 top ' s forklift, one wrap packaging machine, two steel coil reversal machines, two screw air compressor machine ( 5m3 )

    主要輔助設備配置: 20噸橋式吊車4臺, 10噸橋式吊車2臺, 5噸橋式吊車6臺, 20噸平板車1臺, 8噸叉車1臺,纏繞包裝機1臺,鋼卷翻轉機2臺,螺桿式空壓機( 5立方) 2臺。
  13. The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method

    本論文從目前空調工程中使用的變流量水系統入手,研究了盤管換熱器在部分負荷下水流量與換熱量的非線性關系,分析了文獻中介紹的旁通管通流能力選擇的不足之處和一次泵水系統採用壓差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次泵變流量水系統中壓差旁通控製法、回水溫度控製法、負荷控製法的精確性,並得出了在一次泵水系統的工況轉換時,採用負荷控製法能使冷水機組及其相應水泵在啟停時的負荷變化范圍較小,更符合建築物的冷量需求,節能效果較好的結論。
  14. Based on the electromagnetic theories, this dissertation presents analytical method to solve the magnetic field caused by the air - cored solenoid coil

    本論文從電磁場理論出發分析了空心圓柱線圈的磁場,並利用矢量磁位求出了線圈的電感。
  15. Using the vector potential, the expression for calculating inductance of air - cored solenoid coil is derived in the dissertation. and the calculating methods of function t in the calculating expression are given for the convenience of the calculation of inductance while the precision is not strictly requested

    利用矢量磁位a直接推導出了通電空心圓柱線圈電感的計算表達式,給出了求解計算式中函數t的計算方法,以方便精度要求不高時的電感計算。
  16. The influence of the fan - coil units position on the indoor air flow

    風機盤管位置對室內空氣流動的影響
  17. Select air cleaner by fan coil ' s air volume

    根據風機盤管的風量選取相應風量的凈化器。
  18. Analyses the key issues in selecting air - cooled water chillers, adopting fan coil unit and diffuser to supply air and designing of smoke extract fans

    摘要分析了風冷冷水機組選型、用風機盤管接散流器送風、排煙風機控制設計應注意的問題。
  19. There are four primary return air all - air systems in the building ; others are primary air fan coil systems

    全樓共設一次回風式全空氣系統4個,其餘均為風機盤管加新風系統。
  20. The skirt building adopts all - air system, the guest rooms adopt fan - coil unit plus fresh air system, and the water system is four - pipe type

    裙房採用全空氣系統,客房採用風機盤管新風系統,空調水系統採用四管制。
分享友人