bus reactor 中文意思是什麼

bus reactor 解釋
母線電抗器
  • bus : n (pl busses buses)1 公共馬車;公共汽車;客機。2 〈口語〉汽車,機器腳踏車;飛機。3 【電學】信息...
  • reactor : n. 1. 反應者,被試驗者;【醫學】有(陽性)反應的人[動物]。2. 【電學】礙圈,扼流圈;電抗器;【化學】反應器;【物理學】反應堆。
  1. The bisonc burnup library is replaced to facilitate the computation of the burnup process with complicated burnup chains. we have made and evaluated the new library ( hendl ) which contains 139 kinds of nuclides with 175 groups for neutron and 42 groups for gamma, 15 kinds of neutron reactions and p0 - p5 expansion. the revised code which we call bus - id is more adaptable to the computation of hybrid reactor for its fuel breeding and the transmutation of the hlw

    並且在一維輸運及燃耗計算程序bisonc的基礎上,提出用新的數據庫( hendl )代替原有的bisonc數據庫, hendl庫考慮了更加全面的燃耗過程和多種燃料循環方式,通過修正讀入的核截面數據庫中的參數,考慮共振自屏效應,製作並且評估了新的含有139種核素、多種反應截面、 175群中子42群光子、 p _ 0 - p _ 5展開的中子反應數據庫,開發出新的程序bus - 1d ,使得更能適應聚變?裂變混合堆的燃料增殖、高放長壽命核廢料( hlw )的嬗變等計算的要求。
  2. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及電網潮流,總結出了如下規則:隴南電網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償電抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內無功潮流分佈合理、各變電站母線電壓在理想的范圍內時電網有功損耗最小,從而也提高了電網安全運行水平及供電質量。
  3. The study bases on the four operating conditions of which the longnan network will be implemented in the year of 2005 and 2010. first, this paper calculates the power flow distribution that including the line charging reactive power and input of the low - voltage shunt reactor in chengxian s / s. assumed that the bus voltage of tianshui s / s and bikou power plant to be constant, the study count the voltage level of the 330kv and 220kv bus - bar when the 330 / 220kv transformer in standard tap changer position. in order to set control rules

    本文基於隴南電網在規劃發展水平年2005年及2010年的四種可能的運行方式下及潮流條件,計算出了計入線路充電無功及投入成縣變低壓並聯電抗器后的潮流分佈,在設定甘肅大網側及碧口電廠側母線電壓恆定條件下,計算了330kv及220kv主變在有載調壓標準分接頭變比下的330kv及220kv母線電壓水平。