calibration status 中文意思是什麼

calibration status 解釋
檢定狀態
  • calibration : n. 1. 測定口徑。2. 刻度,標度,劃度數。3. 校準;標準化。
  • status : n. 1. 情形,狀況,狀態。2. 地位;資格;【法律】身份。3. 重要地位,要人身份。4. (器材的)本性。
  1. On the basis of practically achieved low - frequency laser - vibration measuring - system, this thesis analyses the principle of laser - vibration measuring - system, the optical factors which have effect on contrast degree of interference fringe, the optical - electric transformation factors which have effect on measuring accuracy, the important of filter for improving the accuracy in the absolute calibration and the outward vibration which has effect on system accuracy, etc. in chapter one, the background of laser measuring vibration, and then followed by its current status, is introduced and analyzed

    本論文根據實際研製的激光測振儀系統,從提高激光測振儀精度的角度出發介紹了激光測振儀的原理,並詳細地剖析了光路對測振儀干涉條紋對比度的影響、光電轉換對測量精度的影響、光電信號的濾波放大以及外界振動對測振儀系統的影響等技術問題。
  2. When intermediate checks are needed to maintain confidence in the calibration status of the equipment, these checks shall be carried out according to a defined procedure

    10當需要利用期間核查以維持設備校準狀態的可信度時,應按照規定的程序進行
  3. The data processing part includes fft, filter and averaging, calibration algorithm, smith chart designing, s - parameter algorithm, transmission and reflection caculating, etc. the hardware interface consists of control information protocol, data transfer protocol, status information protocol and the synchronization protocol of the transfer of all the above information

    數據處理部分包括快速傅里葉變換、濾波與平均、用s參數表示的傳輸反射特性演算法、表示阻抗特性的史密斯圓圖演算法、校準補償演算法、以及實時測量的實現演算法等。介面部分包括控制信息協議、數據傳輸協議、狀態信息協議以及上述各種信息傳輸的同步協議。
  4. Checks needed to maintain confidence in the calibration status of reference, primary, transfer or working standards and reference materials shall be carried out according to defined procedures and schedules

    應根據規定的程序和日程對參考標準、基準、傳遞或工作以及參考物質進行核查,以保持其校準狀態的置信度
  5. When, for whatever reason, equipment goes outside the direct control of the laboratory, the laboratory shall ensure that the function and calibration status of the equipment are checked and shown to be satisfactory before the equipment is returned to service

    9無論什麼原因,若設備脫離了實驗室的直接控制,實驗室應確保設備返回后,在使用前對其功能和校準狀態進行核查並能顯示滿意結果
  6. Whenever practicable, all equipment under the control of the laboratory and requiring calibration shall be labelled, coded or otherwise identified to indicate the status of calibration, including the date when last calibrated and the date or expiration criteria when recalibration is due

    8實驗室控制下的需校準的所有設備,只要可和使用標簽、編碼或其他標識表明其校準狀態,包括上次校準的日期、再校準或失效日期
  7. Based on analyses for the reason of the inaccuracy and the controlled status of the radiation - measurement equipment, this paper points out that the calibration of the radiation - measurement equipment has to be performed periodically during verification intervals, which is determined by the status of the equipment and stepwise weighting method

    摘要通過對檢定間隔期內輻射計量器具量值超差失準原因及受控狀態統計分析,提出檢定間隔期中應按計量器具穩定性情況和分級加權法確定的動態檢定周期實施計量器具動態檢定校準,以保證計量器具狀態受控,確保醫療質量。
  8. To each calibration approach, also discussed the calibration characteristics, existing problems and research status particularly

    詳細介紹了每種標定方法的特點、存在的問題以及研究現狀。
  9. In this dissertation, the present research status of standard vibration metrology technique at home and abroad is introduced, and the significance of developing ultra - low - frequency standard vibration metrology is discussed as well. systematic research has been done in developing ultra - low - frequency standard vibrator. several key technical problems are solved in order to develop the calibration system of this kind of vibrator

    本文在分析了國內外標準振動計量技術的研究現狀以及超低頻標準振動計量的重要性的基礎上,以研製超低頻標準振動臺校準系統為目的,對建立超低頻標準振動臺校準系統的若干關鍵技術及其實現方法進行了研究。
  10. Firstly, the properties of vibration transducers and their calibration methods are given, and the significance of establishing ultra - low - frequency standard vibration calibration system is pointed out. secondly, the present research status on standard vibration metrology at home and abroad is surveyed. thirdly, some problems in the ultra - low - frequency standard vibration metrology and the future direction are pointed out

    首先介紹了振動傳感器的特點及其校準方法,指出建立超低頻標準振動計量的重要性;然後回顧了國內外標準振動計量的研究現狀;接著分析了超低頻標準振動計量存在的問題並指出了研究方向;最後介紹本論文的研究內容。
  11. With the consideration of the characteristics of the low frequency uwb - sar system, the radiometric calibration, polarimetric calibration and the motion status calibration are studied deeply in this thesis

    本文充分考慮低頻uwb - sar系統的特點,從輻射校準,極化校準和運動狀態校準等方面展開深入的研究。
  12. 0 no calibration / pm activity conducted at all / no systematic management of calibration activity, leaving many holes in equipment calibration status

    沒有任何校正/ pm活動/沒有系統管理各項校正活動(工作) ,做成對儀器校正狀況出現多項漏動