current supply loss 中文意思是什麼

current supply loss 解釋
供電損耗
  • current : adj. 1. 通用的,流行的。2. 現在的,現時的,當時的。3. 流暢的;草寫的。n. 1. 水流;氣流;電流。2. 思潮,潮流;趨勢,傾向。3. 進行,過程。
  • supply : vt ( plied) 供給;供應;配給;補充,填補,彌補(不足、損失等)。 Cows supply us (with) milk ...
  • loss : n. 1. 喪失;丟失,遺失。2. 減損,損失,虧損(額);損耗;減少,下降。3. 失敗;輸掉。4. 錯過;浪費。5. 損毀;【軍事】傷亡;〈pl. 〉 傷亡及被俘人數。
  1. The single - chip microcomputer control technology has been applied in the system to carry out monitoring and protective functions for the asynchronous motors controlled. combined with suitable peripheral interface, disposition and flexible software, the mcs can measure the current and voltage signals of the motors. based on the measurements, the computation, judgment and decision are made to implement the phase sensitive short circuit, overload, supply over - voltage, supply under - voltage, over - thermal, leakage lock - out and loss of phase protective function

    系統採用單片機控制技術,完成所控制電動機的控制功能,並對所控制電動機的電壓、電流等信號進行檢測、計算、判斷和處理,實現短路、斷相、過載、欠壓、過壓、過熱、漏電閉鎖等保護功能,並提供本質安全型輸入、輸出介面,能與煤礦井下監測監控系統聯網運行。
  2. With the elevation of the power factor, stator electric current decrease obviously and its range is about 20 %. so voltage loss and electric power wastage decrease effectively on electromotor power supply circuitry consequently

    隨著功率因數的提高,定子電流明顯的減小,減小幅度在20左右,從而有效地減少電動機供電線路的電壓損失及電力損耗。
  3. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷路器所造成的事故無論是在次數,還是在事故所造成的停電時間上都占據總量60以上。因此,及時了解斷路器的工作狀態對提高供電可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷路器機械特性參數監測方法;提出了二次迴路保護器的概念,並將跳、合閘線圈完整性監視和二次迴路保護結合起來,給出具有完整性監視功能的二次迴路保護器實現方案;根據斷路器生產廠家提供的斷路器額定短路電流分斷次數,計算每次分閘對應的觸頭電壽命損耗,預測觸頭電壽命;提出根據斷路器殼體溫度和斷路器周圍空氣溫度結合斷路器熱阻來計算斷路器主觸頭穩態溫升的方法,並根據此時的負荷電流間接計算主觸頭迴路的電阻;在硬體電路設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用電壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作電壓晶元之間的介面問題,並給出了直接聯接的接線方案。
  4. The system had auto startup and stop function by software. the dsp based motor control system had lower current harmonic, more efficient use of supply voltage than spwm, less switch loss. on the other hand, this system make a lower noise for the pwm modulation. frequency is up to 20khz

    本系統實現了電機的軟啟動、軟關斷功能,電機電流的諧波失真較少,電壓利用率比常規的正弦波脈沖寬度調制( spwm )有了較大的提高,器件的開關損耗也得到了明顯的減少。