exhaust coefficient 中文意思是什麼

exhaust coefficient 解釋
排氣系數
  • exhaust : vt 1 用盡,耗盡(資源等)。2 排出(空氣),抽空,空出(容器等);汲干。3 提盡(可溶解的物質)。4 ...
  • coefficient : adj. 共同作用的。n. 1. 共同作用;協同因素。2. 【數,物】系數,率;程度。
  1. Using the opened thermosiphon of 38x3 as experimental element and water as working fluid, the characteristics of dynamic low load boiling, stable severe boiling heat transfer coefficient and critical heat flux are gotten for the opened thermosiphon at the pressure of 0. 02 - 0. 1mpa and 0. 1 - 0. 8mpa respectively, which makes up the drawback that the opened thermisiphon has not yet accurate boiling heat transfer relationship formulas. by means of experimental results, an opened thermisiphon waste heat recovery boiler is designed for the high temperature gases that the positi e electrode copper refining furnace exhaust, which overcomes effectively the drawback of short life, little capacity and unable to inspect that the closed steel - water thermosion has

    本文以工程上常用的38 3的開口封底為實驗元件,以水為工質,對開啟式熱管內的動態低負荷沸騰、穩態旺盛沸騰及臨界沸騰特性進行系統的可視化實驗研究,實驗壓力為0 . 02 0 . 8mpa ,實驗得出了38 3的開口封底管在工作壓力為0 . 02 0 . 8mpa和0 . 1 0 . 8mpa下的管內沸騰傳熱系數及臨界熱負荷計算關聯式,彌補了開口封底管? ?這一新型傳熱元件尚無準確的沸騰換熱關聯式的缺陷。
  2. 1. the author designs special equipment with double - deck, based on the ultimate analysis, caloric, thermodynamic characteristic parameter of layer boiler, working fluid parameters in and out of boiler, exhaust temperature, thermal loss, excess air coefficient, etc. according to processing technology, make special combustion equipment. and it is installed and debugged as required

    根據生物質成型燃料的燃燒特性、層燃鍋爐熱性能及熱力特性參數為設計依據,設計出雙層爐排生物質成型燃料專用燃燒設備;根據燃燒設備的加工工藝製造出生物質成型燃料專用燃燒設備;按照燃燒設備安裝方法及調試方法對該燃燒設備進行了安裝與調試。
  3. Reciprocating internal combustion compression - ignition engines - apparatus for measurement of the opacity and for determination of the light absorption coefficient of exhaust gas

    往復式壓燃式內燃發動機.不透明度測量儀器和廢氣吸光系數測定儀器
  4. The condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    建立了空氣冷卻實驗臺,熱管的加熱方式為電加熱,工質為蒸餾水.在1 1模型上對分離式熱管管內凝結換熱特性、不凝性氣體對凝結換熱的影響及不凝性氣體的擴散規律進行了試驗,得出分離式熱管有一最佳充液率,其值為45 %左右;凝結換熱系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離式熱管的凝結換熱僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性氣體對分離式熱管冷凝段的影響減少.這些結論可用於分離式熱管換熱器的工程設計和控制
  5. Abstract : the condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    文摘:建立了空氣冷卻實驗臺,熱管的加熱方式為電加熱,工質為蒸餾水.在1 1模型上對分離式熱管管內凝結換熱特性、不凝性氣體對凝結換熱的影響及不凝性氣體的擴散規律進行了試驗,得出分離式熱管有一最佳充液率,其值為45 %左右;凝結換熱系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離式熱管的凝結換熱僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性氣體對分離式熱管冷凝段的影響減少.這些結論可用於分離式熱管換熱器的工程設計和控制