fault arc 中文意思是什麼

fault arc 解釋
故障電弧
  • fault : n 1 過失,過錯;罪過,責任。2 缺點,缺陷,瑕疵。3 (獵狗的)失去嗅跡。4 【電學】故障,誤差;漏電...
  • arc : A. R. C. = American Red Cross 美國紅十字會。n. 1. 弧;弓形,拱(洞)。2. 電弧,弧光。
  1. Chagan fault depression is a secondary tectonic unit in chagandelesu subbasin, northeastern yingen - ejinaqi basin, and the basement of the basin is a paleozoic fold belt of continental margin or island arc with the character of erogenic belt at the connection region of north china plate, tarim plate and kazakstan plate

    查干德勒蘇凹陷屬于銀根?額濟納旗盆地東北端查干德勒蘇坳陷內的一個次級構造單元。其基底為古生代時期華北板塊、塔里木板塊和哈薩克斯坦板塊交接部位的陸緣或島弧褶皺帶,具有古生代造山帶的性質。
  2. In this case during paleozoic, nearly east west trending arc structures resulted from the interaction between china plate and siberian plate. in mesozoic the westward subduction of kula - pacific plate under the china continental plate resulted in the nne and ne trend structures ( duimadao fault, diaoyudao fault, okinawa fault, uplifts belts and subsidence belts ) as well as volcano - magmatic belts in eastern of china plate

    本文所涉及近東西向展布的弧形構造形成於古生代時期中國板塊與西伯利亞板塊的碰撞帶,而在中生代,中國板塊下的kula - pacific板塊向西俯沖導致了北北東向和北東向構造(如duimadao斷層、 diaoyudao斷層、 okinawa斷層、隆起帶和沉降帶)以及位於中國板塊東部的火山巖漿帶。
  3. According to the quickly adjustable characteristic of the peterson coil grounding system, this dissertation proposes a new control strategy. when the system is in operation, the strategy can limit the series resonance over - voltage by using the off - resonance method. when fault occurs, the strategy can conveniently suppressing arc by rapidly adjusting the inductance value of the peterson coil to the point, which the resonance with grounding capacitance of the power network is occurred

    依據可控硅控制消弧線圈接地系統的快速可控性,一改傳統的電網正常運行時調節消弧線圈接近於全補償的預調諧方法,提出正常運行時採用脫諧方法抑制串聯諧振過電壓;故障時立即調節消弧線圈電感量達到與對地電容諧振,以利熄弧的新型調節原理和方法。
  4. New designed auto tracing arc eliminating device based on this technique contents more technology, which has sample circuit, wide tuning scope, quick response and low noise. this paper firstly introduces neutral grounding histroy. by analyzing the syntony grounding theory, the transient and stable process of one - phase grounding fault, the threaten to secure run of power system and the importance of exact compensation for capacitive current are cognized

    論文中首先介紹了中性點接地方式的發展過程,通過對諧振接地原理和單相接地故障的暫態、穩態分析,認識到接地故障對系統安全運行的危害,通過消弧線圈對接地電容電流的迅速準確補償是減小故障危害的最主要手段。
  5. Based on researching the function of every kind of eliminating arc loop, new concept was brought up in this paper, and the protective device for eliminating arc and overvoltage was researched and manufactured. when the arc light connecting the ground emerges, the chip synthesizing controller control the vacuum contacter which can be operated with dividing phase and make its fault phase earthed so that the arc light can be dissolved thoroughly

    本文在研究各種消弧線圈的基礎上,提出全新的概念,研製出了消弧及過電壓保護裝置,該裝置在出現弧光接地時,通過單片機綜合控制器控制一組可以分相操作的真空接觸器,使故障相接地,達到徹底消除弧光的目的。
  6. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  7. Arc - grounding fault line selection is the paper ' s key point and innovative point about small current grounding power systems. a lot of simulations are made based on the change rule and the character of fault voltage, fault current. the simulation study declare that the use of the method of wavelet analysis can select the fault line when the arc - grounding fault take place, it will play a important directive role in the research of the protection equipment

    對小電流接地系統電弧故障的選線模擬是本文的重點,也是一個創新點,本文從研究的角度,在深入分析電弧接地時故障電壓、電流的特點和變化情況的基礎上,進行了大量的選線模擬,模擬表明電弧故障時,小波分析方法也能準確地選出故障線路,這對研製高性能的接地保護裝置將起到重要的指導作用。
  8. According to the structural characteristic of distribution network, a method for fast - fault - location is proposed. this method required an arc - structure matrix and is based on the practical information achieved by ftu

    由於配電網路的故障后重構方案的得到具有多約束、非線性和整數尋優的特點,用常規的數理方法求解往往不能令人滿意。
  9. As the electric power & electronic technology is used widely in low voltage area, the properties of voltage and current in normal working conditions of electrical appliance closely resemble or mimic the un - normal properties created by the arc fault, so it is difficult to distinguish between normal and un - normal cases

    隨著電力電子技術在低壓領域的廣泛應用,一些電器正常工作時的電壓電流特性與故障電弧的典型特性相似,給檢測工作帶來了難度。
  10. The influences of several factors such as harmonics, intermittent arc grounding, ct, load and fault resistance have been thoroughly analyzed, therefore, it is fundamental work for its application

    深入細致地分析了諧波、間歇電弧、電流互感器、負荷、過渡電阻等多個因素對故障選線結果的影響,為方案的實用化奠定了基礎。
  11. So the development of self - energy sf6 cb is very important. in the paper, the math model of arc - quenching chamber air - pressure character is built on the base of 126kv / 31. 5ka self - energy sf6 cb ' s exploiting, then the theory analysis and calculation is deeply been done for cylinder radius, nozzle spout radius and opening position of moved contact that they have the essential effect for the use of arc energy in the course of opening. arc - quenching chamber parameter is confirmed according to the request of full opening and fault opening when the cb is opening

    本文針對126kv31 . 5ka自能式sf _ 6斷路器的研製,建立了相應的滅弧室氣壓特性數學模型,對自能式sf _ 6斷路器開斷過程中電弧能量利用有重要影響的滅弧室缸徑、噴口直徑、動觸桿開口位置進行了詳細深入的理論分析和計算,並根據斷路器開斷中的滿容量開斷和近區故障開斷的要求確定了滅弧室參數。
  12. This layout can stop the internal arc fault expansion ; can avoid harmful moisture, small animal and dusty interferences. it also has good perfomiance and high reliability. because the heat cannot transmit to the outside of the bus room, a good operation environment for the low space can be obtained

    主母線室置於箱體頂部一個單獨的金屬封閉的間隔內,並與10kv開關室、儀表室等間隔相互獨立,為同類產品首創;這種結構可以防止內部電弧故障的擴大化,避免「火燒聯營」事故;防護性能好,防潮、防小動物侵害、防積塵,運行可靠;由於母線室的隔熱作用,為下層空間創造了一個較好的運行環境。
  13. Arc - shaped fault break slope system and its control on low stand systems sandbodies in dongying depression

    東營凹陷弧形斷裂坡折帶系統及其對低位域砂體的控制
  14. After the neutral point is grounded through perterson coil, it can decrease the capacitor current through fault point and the over - voltage caused by the grounding fault, which is advantage for the extinguishments of electric arc

    中性點經消弧線圈接地后,有效減小了流過故障點的電容電流,減小了弧光接地過電壓,有利於電弧熄滅。
  15. After the neutral point is grounded through peterson coil, it can decrease the capacitor current through fault point and the over - voltage caused by the grounding fault, which is advantage for the extinguishments of electric arc

    中性點經消弧線圈接地后,有效地減小了流過故障點的電容電流,減小了弧光接地過電壓,有利於電弧熄滅。
  16. A method for fast - fault - location required an arc - structure matrix and is based on the practical information achieved by ftu, and then we can get some solution of " large area restoration " on basis of the five object functions mentioned in this paper

    也是配電網路運行的主要目標之一。配電網路的故障隔離和故障后網路的重構是在遙測元件上傳信息的基礎上,根據當前配電網路的拓撲信息,來對故障區域進行定位和隔離。
  17. Fire accident can arise from low - voltage arc fault, and so it is necessary to detect arc fault

    摘要低壓故障電弧有引發火災的危險,所以檢測故障電弧是必要的。
  18. After the comparing of all arithmetic, the paper points out the now all arithmetic is limited when the system is anti - arc system, which makes it difficult for fault to defect

    對各種演算法的比較之後,指出了目前各種演算法在中性點經消弧線圈接地情況下都有一定的局限性。
  19. For this reason, the paper gives two new arithmetic, current break arithmetic and net arithmetic, which solve the problem of fault detection in anti - arc system effectively

    為此,本文提出了兩種全新的演算法,電流突變量演算法和網路演算法,有效的解決了中性點經消弧線圈接地情況下單相接地故障選線的問題。
分享友人