heating load 中文意思是什麼

heating load 解釋
供暖負荷
  • heating : adj. 1. 加熱的;供熱的。2. 刺激的。n. 1. 加熱;供暖;(建築物的)暖氣裝置。2. 白熾,灼熱。
  • load : n 1 裝載,擔子;負擔;工作(負荷)量。2 (車船等的)裝載量;一馱,一車,一飛機。3 【電、機】(機...
  1. The test shall demonstrate to the satisfaction of the owner that the equipment meets all specified performance criteria, is properly installed and anchored, and operates smoothly throughout the specified speed range without exceeding the full load amperage rating of the motor or excessive motor heating

    測試應該讓用戶滿意,證明這些設備符合所有規定的性能標準,經過正確的安裝和錨固,在額定轉速范圍內運行平穩,沒有超過電機的額定滿負荷運轉電流安培數,或發生電機過熱。
  2. Load predictions for district heating systems based on a wnn model

    基於小波網模型的區域供熱系統負荷預測
  3. Ssr - dd series of dc solid relay is vastly applied to output joggle of computer and external equipments, it is also applied to control or switch dc load : dc relay 、 contactor 、 dc electrical motor 、 kinds of electric - heating apparatus 、 dc electromagnetic valve 、 electromagnetic iron 、 solenoid 、 filament lamp 、 indication lamp 、 plc logical electrical appliance and dc solid relay

    Dd系列直流固態繼電器廣泛應用於計算機與外部設備的輸出介面,適用與控制或開關直流負載:直流繼電,接觸器、直流電動機、各類電熱器具;直流電磁閥,電磁鐵、螺線管、白熾燈、指示燈; plc邏輯電器。
  4. At last, there is a practical design of gshp - radiant system in a villa in chongqing. the compare of the gas - heater radiant floor system and the gshp radiant floor system indicates that the heating performance coefficient of the gshp is higher than the gas - heater to a large extent. in addition, this united system can use the closed circling water in the underground heat exchanger to remove the surplus heat load in transitional season

    通過燃氣熱水器制熱的輻射地板供暖與地源熱泵制熱的輻射地板供暖性能實驗的對比,可以看出地源熱泵的供熱性能系數高於燃氣熱水器,同時在長江中下游地區還可在過渡季節利用閉式循環水吸收土壤冷量對房間進行供冷,提高系統運行的經濟性。
  5. The thesis adopted the effective heat transfer coefficient to heating load calculation, through it, we discover that : the heat consumption of the lowest story door, highest story door and the door stick to gable wall is more than the center door of the building, further approved the necessity that the communal heating load calculation are abstracted and allocated averagely

    本文採用有效傳熱系數法對耗熱量進行計算,通過本文的研究發現:住宅的底層用戶、頂層用戶及有山墻用戶的耗熱量遠高於中間住戶的耗熱量,進一步說明了提取公共耗熱量並將之按面積平分的必要性。
  6. The general situation of natural gas source in china and the economy of wall - mounted gas boiler for individual heating are analyzed, and the current situation analysis and forecast on heating load of gas heating are made

    摘要分析了我國天然氣的氣源概況和燃氣壁掛爐分戶採暖的經濟性,進行了燃氣採暖熱負荷的現狀分析和預測。
  7. ( 2 ) according to the national request of northern winter heating design, heating load is calculated in this paper

    ( 2 )按照國家關于北方地區冬季採暖設計的要求,進行了採暖負荷計算。
  8. Given the thermal physical parameters of the envelops and the weather data, the above two parameters are determined by the following system design parameters : radiant panel dimension, radiant panel location and radiant panel layout style ( center or peripheral ). based on the thermal net model, digital analysis of the energy consumption and thermal environment are carried out to the several representative spaces under different design parameters, through which the relations of the heating load to the design parameters are obtained and can be a reference in the practical system design

    對于給定圍護結構熱物性參數和室外氣候參數的條件下,室內平均輻射溫度和室內空氣溫度的大小取決于系統的設計參數:輻射板的布置方式(周邊布置和中心布置) 、輻射板尺寸和輻射板鋪設位置。基於熱網模型,利用matlab軟體編程對採暖空間在不同設計參數下室內的熱環境和能耗進行數值分析,得出了低溫熱水地板輻射採暖系統的性能和能耗指標隨這些參數變化的規律,從而為低溫熱水地板輻射採暖系統的優化設計提供了參考。
  9. With an actual ground source heat pump system example, based on the hourly calculation of annual cooling and heating load, carries out numerical simulation on heat transfer characteristics of the soil around compact pile - buried underground heat exchangers with large land area

    摘要以一實際地源熱泵系統為例,在全年逐時負荷計算的基礎上,對大面積密集型樁埋換熱器管群周圍土壤的換熱特性進行了數值模擬。
  10. The thesis introduces the charging method of household heat - metering and academic calculating formulas of all the abstracted coefficient of the communal heating load calculation from the total heating load calculation in household heat - metering and charging in multiplayer buildings

    文中介紹了按戶熱計量的收費方法及多層住宅建築熱計量耗熱量中公共耗熱量的提取系數的理論計算公式。
  11. By using the academic calculating formulas of each factors, we can analyze and calculate the no. 23 # residence building of abstracted coefficient that is measured by ledge in baihua small region. finding the abrration between practicable heat test and theory calculation, sequentially the communal heating load calculation is abstracted from the total heating load calculation of the building

    應用各個系數的理論計算公式,對百花小區23 #住宅樓公共耗熱量的各個提取系數進行分析計算。找出實際測試與理論計算兩者之間的誤差,提取出公共耗熱量。
  12. The thesis aims at a muliti layer residence project of in jinan baihua small region. according to the heating system of the separating doors in this building controlled by heat meter measurement, it studies the feasibility of the various abstracted cosfficient of the communal heating load calculation. also it studies the difference from the practice. according it, we can draw conculution that the communal heating load calculation are abstracted and allocated averagely according area and added to the variable heating load calculation, taking for the charging heating load calculation

    本文將濟南市百花小區的一棟多層住宅為研究對象,根據該住宅室內分戶控制按熱表計量的供暖系統,研究其耗熱量中公共耗熱量各項提取系數的可行性及其與實際測量的誤差,得出將公共耗熱量提取出來,然後按面積分攤到各住戶的可變耗熱量中,作為計費耗熱量的合理性結論。
  13. Compared the heating load ( and energy consumption ) of a same room with floor heating or radiator heating under same operative temperature. revealed the energy consumption of floor heating room could reduce 5 % ~ 10 % to radiator heating, and the heating load could reduce 10 % ~ 15 %. the main season of energy efficiency is due to no apparent high temperature zone in floor heating room, which avoid additional heat loss in outside envelopes, rather than the lower of indoor air temperature

    利用對連續供暖房間溫度場的研究結果,對分別採用上述兩種供暖方式的典型房間的熱負荷和能耗進行了全面分析后發現:低溫地板輻射供暖房間熱負荷比散熱器供暖房間可降低10 15 ,能耗可降低5 10 ;低溫地板輻射供暖房間節能的主要原因並不是由於房間空氣溫度可以降低,而是消除了室內空氣局部高溫區,避免了由此產生的在外圍護上的附加傳熱量。
  14. Firstly, based on the utilization of the first and second law of thermodynamics, the ideal combined camot cycle model is set up. secondly, aimed at the insufficient of the classical thermodynamics analysis method, the popular method - - finite time thermodynamics analysis is applied to set up the model of endo - reversible combined carnot cycle. finally, the optimization relationships between the specific heating load ( shl ) and operating parameters and between shl and cop are conducted according to the characteristics of the function and investment of aht

    在首先利用熱力學第一、二定律分析方法的基礎上,建立了吸收式熱變換器的理想聯合卡諾循環模型,然後針對經典熱力學分析方法的不足,利用了當前很流行的有限時間熱力學分析手段,建立了aht系統內可逆聯合卡諾模型,根據熱變換器的功能、投資等方面的特點,導出了吸收式熱變換器比供熱率與操作參數、比供熱率與熱力學性能系數的優化體系。
  15. Firstly, aiming at solving the difficult problem in scheduling control of the heating load in a practical district heating system, a strategy is proposed which can realize the real balance between the quantity of heat needed for the resident and the quantity of heat provided by heating plant

    首先,針對目前供熱系統熱源負荷控制中的難點問題,提出了通過綜合分析系統運行數據,間接提煉出供熱系統熱負荷需求模式,並通過動態預測補償的方法以實現真正意義上的按需供熱。
  16. On the base, integrated development environment of vb is used to develop software of simulation and optimization of aht cycle system. after the software ass is developed, it is applied to an industrial instance, including process simulation, thermal analysis and specific heating load ( shl ) optimization

    在此基礎上,利用vb集成開發環境,展開了aht吸收循環系統模擬優化軟體的開發工作,並開發出軟體ass ,實現了過程模擬優化計算,包括:過程模擬、熱力學分析和比供熱率優化等計算模塊。
  17. By the weather data of typical year from meteorological observation, the building facing correction factors of heating load of 27 cities in china are listed. not only the effect of direct solar radiation on the building facing correction factor, but also that of diffuse solar radiation is considered. this paper also analysis the effect of different building facing correction factors on the calculation of heating load

    以各氣象臺站實測典型年氣象資料為基礎,綜合考慮了直射輻射和散射輻射兩種情況,給出了全國27個城鎮的各朝向修正系數,並對採用不同修正系數對房間負荷計算的影響進行了對比分析。
  18. In the same time, the temperature curve in design day was obtained. through the studies of the above problems, the key problem of heating load calculation and the criterion of building energy efficiency was resolved. it is significant for perfecting heat metering technique and providing specifications of hvac

    通過對以上問題的研究,解決了計量供熱系統熱負荷計算的核心問題,達到了建築節能的目的,從而對完善分戶熱量計量控制技術,以及對相關暖通規范的編寫有一定的指導意義。
  19. However, due to the supplying air volume change corresponding to cooling or heating load change, such phenomena as uneven temperature and velocity distribution often take place, which lead to bad indoor air distribution and thermo - environment

    然而在變風量空調室內,因為送風量隨著室內負荷的變化而變化,經常存在溫度和速度分佈不均勻現象,導致室內不良的氣流組織和不舒適的熱環境。
  20. For the space heated by low - temperature water floor radiant heating system, the mean radiant temperature and air temperature are two main factors that affect the indoor thermal quality as well as the building energy consumption, so how to minimize the heating load as much as possible on the condition of securing thermal comfort demand

    採暖空間的室內熱舒適度主要是由兩個因素來決定的:室內平均輻射溫度和室內空氣溫度,這兩個參數同時也影響室內採暖系統的能耗大小,因此,如何在保證室內人體熱舒適要求的條件下,最大限度地減少低溫熱水地板輻射採暖系統的能耗
分享友人