humidity coefficient 中文意思是什麼

humidity coefficient 解釋
濕度系數
  • humidity : n. 濕氣;【物理學】濕度。 absolute humidity【物理學】絕對濕度。 relative humidity【物理學】相對濕度。
  • coefficient : adj. 共同作用的。n. 1. 共同作用;協同因素。2. 【數,物】系數,率;程度。
  1. The main results indicated that : significant differences exist in diurnal average transpiration rate and the range of diurnal transpiration rate ; the transpiration rate of sawtooth oak, amorpha, lalang grass varied with a regular double apex rhythm, but that of the rest varied with a regular single apex rhythm, stomatal conductance play a maximal important role in transpiration rate, temperature ( air temperature, the earth ' s surface temperature ) also influence the transpiration rate ; transpiration rate has prominent negative correlation with the relative air humidity, the biggest coefficient is 0. 866

    筆者對日照沿海防護林幾種主要木本植物和草本植物的蒸騰速率和環境因子的關系進行了研究,結果表明: 8種植物日平均蒸騰速率和蒸騰速率日變幅各異;麻櫟、紫穗槐和白茅的蒸騰速率日變換呈現出雙峰式的變化規律,其它5種植物蒸騰速率表現為單峰式的變化規律;氣孔導度影響著植物的蒸騰速率,溫度(氣溫、地面溫度)是影響植物蒸騰速率的主要因子;空氣相對濕度和蒸騰速率表現為顯著或極顯著負相關,相關系數高達0 . 866 。
  2. In this research, through the test in geometric parameter and resistance performance, and comparison between random and other stacked packing, pvc screw thread oblique corrugated plate have more advantage. combined with test and theoretic calculate, determined the heat and mass transfer coefficient, obtained the influence relationship between inlet air flow rate, temperature and humidity, inlet liquid desiccate flow rate, temperature and concentration with outlet air humidity in dehumidifier, provided consideration for equipment design and production

    通過對除濕塔的現場測試並結合理論計算,確定其熱質交換系數,並分析得出採用pvc螺紋斜波紋板填料的一定結構的除濕塔,處理空氣的風量、入口溫度和含濕量及除濕溶液流量、入口溫度和濃度對空氣出口含濕量的影響關系,為除濕設備的設計和指導生產運行提供參考。
  3. Lewis relationship has been suggested to evaluate the surface mass transfer coefficient using the average surface convective transfer coefficient. in addition, a practical analytic technique for testing the surface mass transfer coefficient is proposed and the values of he surface mass transfer coefficient have been given for the particular desorption and absorption test and validated against lewis relationship results. indoor temperature and humidity evaluation equations of adobe buildings considering the moisture absorption and desorption by interior materials have been proposed based on the analysis of the indoor dynamic thermal and moisture process

    通過理論解析和實驗測試定量地研究了生土建築圍護結構表面吸放濕效應,首次提出了以空氣濕度( kg / kg )為驅動勢差的圍護結構表面吸放濕量計算公式,該公式較適用於工程計算,從而為使建築濕環境研究成果逐步應用到建築工程實踐中奠定了理論基礎和提供了簡便演算法;通過對國內外關于表面質交換系數確定方法的研究成果的分析,提出用lewis關系計算生土建築圍護結構表面質交換系數;在實驗室環境下,對生土建築圍護結構表面質交換系數進行了測試方法研究,測試結果和利用lewis關系得到的數值較接近。
  4. Introducing the thermal performance calculation method called efficient factor method with the medium of the exchange coefficient on the base of the key factors which influencing the heat and humidity ' s exchange, the characters ordinary mathematics equations stem from the analysis the double spray chamber ' s thermal performance calculation identically utilizing efficient factor method, further the equations working as the core of the theory calculation and the utilization of the spray chamber ' s structure and the definition of the experimental equations, further introducing the double spray chamber ' s thermal performance calculation equations

    雙噴系統熱工計算同樣採用效率系數法,進而在理論部分引出雙噴系統熱工計算方程式,這實質上就得到了本課題的核心部分? ?組合方程組,無論是理論計算還是噴水室結構類型的採用以及試驗公式的確定均以此為核心,從而最終從理論計算、試驗測定及節能性三方面論證了雙噴水室熱回收方案的可行性。
  5. The additional sub - scale flux is mainly determined by the average grid value, coefficient of variation and correlations among the meteorology parameters. ( 2 ) the additional sub - scale turbulence flux is composed by two parts, one part is induced by the correlations among the transfer coefficient, surface temperature and soil humidity, another is caused by non - line relationship between the transfer coefficient and roughness, stability

    ( 2 )非均勻分佈引起的附加次網格地表湍流通量主要由兩部分組成:一是地表次網格上輸送系數和地表溫度、濕度的相關項,另一是由於模式中計算整體輸送系數時,整體輸送系數是地表粗糙度和穩定度的非線性函數所造成擾動項。
  6. The relationships between the cycle cop ( coefficient of performance ), the cooling capacities ( qe ) of the system and the hot air temperature, between cop, qe and the ambient air temperature, relative humidity, between cop, qe and the wet air temperature at the generator upside, between the system general efficiency and the hot air temperature are found

    得出系統製冷量、 cop值、總效率隨環境空氣溫度和相對濕度、太陽能集熱板出口空氣溫度以及發生器出口空氣溫度的變化關系。通過研究發現,當熱空氣達到一定溫度時,循環具有較好的穩定性。
分享友人