shunt reactor 中文意思是什麼

shunt reactor 解釋
並聯電抗器
  • shunt : vt 1 逃避,躲開,閃開;〈口語〉將(工作、義務等)推給別人;拖延,擱置(計劃、討論等)。2 【鐵路】...
  • reactor : n. 1. 反應者,被試驗者;【醫學】有(陽性)反應的人[動物]。2. 【電學】礙圈,扼流圈;電抗器;【化學】反應器;【物理學】反應堆。
  1. The study on single - pole adaptive reclosure of ehv transmission lines with the shunt reactor

    帶並聯電抗器的超高壓輸電線單相自適應重合閘的研究
  2. Series reactor is applied to ac power system with rated voltage of 6kv - 63kv and series connected with shunt capacitor banks for restraining wave distortion in grid voltage so as to improving the quality of power system and ensure the safety of its operation. it can restrain harmonic current and surge current in capacitor banks so that the capacitor will operate reliably

    Ckdk型串聯電抗器,適用於6 63 kv電力系統中,與並聯電容器相串聯,用以抑制電網電壓波形畸變,從而改變電網質量和保證電力系統安全運行抑制流過電容器組的諧波電流和限制合閘涌流,從而保護電容器的安全可靠運行。
  3. Dry - type air - cored series reactor is applied to ac power sys - tem with rated voltage of 6kv 10kv 35kv and series connected with shunt capacitor banks for restraining wave distortion in grid voltage so as to improving the quality of power system and ensure the safety of its operation

    乾式空芯串聯電抗器適用於6kv 10kv 35kv電力系統中與並聯電容器組串聯,用於抑制電網電壓波形畸變,從而改善電網質量和保證電力系統安全運行,抑制流過電容器組的諧波電流和限制合閘涌流,從而保護電容器使之安全運行。
  4. High voltage shunt capacitor installation is comp - rised of capacitor cabinets or steel racks capacitor, special fuses for capacitor overload protection, capaci - tor discharge device, air - cored reactor which is applied to restrain surge current and high frequency harmonic, zno arrester without gaps for overvoltage - limiting and high voltage vacuum switch etc. capacitor cabinet is

    高壓並聯電容器成套裝置主要由電容器櫃或鋼架電容器電容器過負荷保護專用熔斷器放電裝置專用放電線圈或電壓互感器,抑制涌流限制高次諧波的空芯電抗器和限制過電壓的無間隙氧化鋅避雷器及高壓真空開關
  5. Application guide for shunt reactor switching

    分路電抗器開關的應用指南
  6. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及電網潮流,總結出了如下規則:隴南電網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償電抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內無功潮流分佈合理、各變電站母線電壓在理想的范圍內時電網有功損耗最小,從而也提高了電網安全運行水平及供電質量。
  7. High voltage shunt capacitor installation is comprised of capacitor cabinets or steel racks capacitor, spe - cial fuses for capacitor overload protection, capacitor discharge device, air - cored reactor which is applied to restrain surge current and high freq. harmonic, zno arrester without gaps for overvolage - limiting and high voltage vacuum switch etc. capacitor cabinet is made of highquality cold - rolling steel plate

    高壓並聯電容器成套裝置主要由電容器櫃或鋼架電容器電容器過負荷保護專用熔斷器放電裝置抑制涌流限制高次諧波的空芯電抗器和限制過電壓的無間隙氧化鋅避雷器及高壓真空開關等設備組成。
  8. The study bases on the four operating conditions of which the longnan network will be implemented in the year of 2005 and 2010. first, this paper calculates the power flow distribution that including the line charging reactive power and input of the low - voltage shunt reactor in chengxian s / s. assumed that the bus voltage of tianshui s / s and bikou power plant to be constant, the study count the voltage level of the 330kv and 220kv bus - bar when the 330 / 220kv transformer in standard tap changer position. in order to set control rules

    本文基於隴南電網在規劃發展水平年2005年及2010年的四種可能的運行方式下及潮流條件,計算出了計入線路充電無功及投入成縣變低壓並聯電抗器后的潮流分佈,在設定甘肅大網側及碧口電廠側母線電壓恆定條件下,計算了330kv及220kv主變在有載調壓標準分接頭變比下的330kv及220kv母線電壓水平。
  9. According to zero sequence voltage distribution from system zero sequence impedance to shunt reactor zero sequence in zero sequence circuit, the zero sequence voltage at the terminal of shunt reactor and the zero sequence compensating voltage at neutral are compared in the scheme

    即根據零序網路中零序電壓在系統零序阻抗和電抗器零序阻抗上的分佈情況,通過直接比較電抗器首端零序電壓與補償到電抗器末端中性點的零序補償電壓的幅值大小,來判別電抗器匝間故障。
  10. High voltage shunt capacitor installation is comprised of assembling capacitor, high voltage vacuum or sf6 switch, serial reactor, zno arrestor and discharge device. because of its simple structure, small cubage, high output,

    由集合式並聯電容器和高壓真空或六氟化硫斷路器串聯電抗器氧化鋅避雷器及放電線圈等設備組成的高壓並聯電容器成套裝置,具有裝置結構簡單體積小容量大佔地省
  11. The feasibility and principle of acsd test of ehv shunt reactor with series compensation method are analyzed. the examples are presented

    摘要分析了用串聯補償法進行超高壓並聯電抗器acsd試驗的原理和可行性,並給出了實例。
  12. Application guide for ac high voltage circuit breakers for shunt reactor current switching

    並聯電抗器電流轉換用交流高壓斷路器的應用指南