single wire circuit 中文意思是什麼

single wire circuit 解釋
單線電路
  • single : adj 1 僅只一個的,單獨的;單式的;【植物;植物學】(花等)單瓣的;【無線電】單工的,單次的。2 獨...
  • wire : n 1 金屬線,銅絲,鐵絲,鋼絲;【電學】導線;線路;金屬絲網;【造紙】抄網。2 電信;〈口語〉電報。3...
  • circuit : n 1 (某一范圍的)周邊一圈;巡迴,周遊;巡迴路線[區域];迂路。2 巡迴審判(區);巡迴律師會。3 【...
  1. Adsl, symmetrical dsl ( sdsl ), high - bit - rate dsl ( hdsl ), very high dsl ( vdsl ), and rate adaptive dsl ( radsl ) use intelligent devices similar to network cards at each end of a single twisted - pair copper wire circuit to deliver very high speeds over copper wire for distances ranging from hundreds of feet to 18, 000 feet

    Adsl (不對稱數字用戶線) 、 sdsl (對稱數字用戶線) 、 hdsl (高位速率數字用戶線) 、 vdsl (極高速數字用戶線)和radsl (速率自適應數字用戶線)都使用了與網卡類似的智能裝置,它們裝在單根雙絞銅線的兩端,以在幾百到18000英尺的距離范圍內在銅線上提供極高的傳輸速度。
  2. This paper describes mainly system functions, measuring methods, circuit design, software program and errors analysis of a new type of measuring instrument. this instrument can measure and monitor electric parameters in single - phase circuits, three - phase ( three - wire or four - wire ) circuits. this system can be applied to electric devices and power plants, transformer substations with harmonic pollution. it can measure current, voltage, power, energy, frequence, power factor etc. it also can detect load quality, phase sequence, alarm, display and print results, as well as detect and dispose negative power

    該儀器適用於含有諧波污染情況下的機電設備現場、發電廠、供電局、企業變電所現場,可用來測量電流、電壓、有功功率、無功功率、視在功率、有功電能、無功電能、視在電能以及頻率和功率因數等電參數,並具有負載性質(感性、容性)判別,正、逆相序判別指示功能;超限報警功能;列印記錄功能和負功檢測及處理功能。
  3. This can fully consider the effect of the structure of transmission line and the selection of lighting parameter etc. by calculating and analyzing various of factor that affect the lightning tripping probability of 500kv double circuit transmission line, we can draw the conclusions : the result by intersecting method is more accord with the practicality circumstance than by existing standard methods, using unbalance high insulation and reverse sequence of wire can reduce the contemporary outage rate of double circuit line, reducing the footing resistance is one of the most efficiency method to reduce the back stroking rate of double circuit transmission line, the double back stroking rate and the single back stroking rate will fall by three ground wire, when the footing resistance is 10 ohm, the back stroking rate by three ground wire is 83 percent of by two ground wire

    在分析輸電線路繞擊耐雷性能時,對線路的雷電屏蔽問題進行了分析,提出對擊距法進行改進,充分考慮了風速的影響因素,編寫了具有工程實用價值的計算線路繞擊耐雷水平的程序,此方法可以充分考慮線路結構和雷電參數等對繞擊率的影響。通過對影響500kv同桿雙回線路雷擊跳閘率的各種因素進行了計算和分析,得到以下結論:採用相交法的計算結果比定義法更符合實際運行情況。採用不平衡高絕緣方式和導線逆相序排列可以大大降低雙回同時跳閘率。
分享友人