  1. This paper separately analyzed the principle and characteristic of water condensing + water condensing mode and air condensing + water condensing mode of compound condensing method. it is found that the building heating and cooling systems applied compound condensing method can well integrate the function of space cooling and space heating and sanitary hot water heating. the compound condensing method could well preserve energy, and its integration makes the investment of building heating and cooling system more economical

    論文對復合冷凝技術的水冷+水冷模式和風冷+水冷模式的原理分別進行了探討,討論發現此技術能使冷熱源機組將空調製冷、空調供暖、生產衛生熱水等功能互相結合起來,節能效果顯著,集成化的功能也使得建築冷熱源設備的初投資也大大減少,並很大程度上緩解了建築冷熱源設備對環境的熱污染和城市的「熱島效應」 。
  2. Using the matlab tools, a computer program is compiled to solve this mathematic model, by which simulations to the thermal environment of the heated space under different heating style are carried out. the simulations results and their analysis show that for different space with the same thermal comfort index, the energy consumption of low - temperature water floor radiant heating system is less than that of convection heating system

    基於上述採暖空間的熱網模型,運用matlab數學軟體編程,對低溫熱水地板輻射採暖方式和對流採暖方式下房間的熱環境進行動態分析,並對這兩種採暖方式下採暖系統的能耗進行計算機模擬計算,結果表明低溫熱水地板輻射採暖系統相對于對流採暖系統有顯著的節能性。
  3. Based on the thermal conservation principle, a thermal net model is established for the heated space, which can undergo dynamic analysis to the thermal environment of heated space and go on the heating system performance assess

    本文將根據室內空氣和圍護結構內表面的熱平衡,建立一描述採暖房間室內傳熱過程的熱網模型,基於該熱網模型,可以進行採暖空間熱環境動態分析和採暖系統能耗分析評價。
  4. Fans consume more power than the pumps of a liquid system, but if the unit is installed in a facility that uses air distribution, only a slight power cost is chargeable against the solar space - heating system

    風扇比起液體系統的泵,需要更多能量,但是如果工廠中建立的使用空氣分配的單元,相對太陽能空間加熱系統,僅僅需要很少的能量付出。
  5. For the space heated by low - temperature water floor radiant heating system, the mean radiant temperature and air temperature are two main factors that affect the indoor thermal quality as well as the building energy consumption, so how to minimize the heating load as much as possible on the condition of securing thermal comfort demand

    採暖空間的室內熱舒適度主要是由兩個因素來決定的:室內平均輻射溫度和室內空氣溫度,這兩個參數同時也影響室內採暖系統的能耗大小,因此,如何在保證室內人體熱舒適要求的條件下,最大限度地減少低溫熱水地板輻射採暖系統的能耗