surge impedance 中文意思是什麼

surge impedance 解釋
波動阻抗
  • surge : n 大浪,波濤;波濤洶涌的大海;(人群、感情等的)洶涌,洋溢,起伏,高漲;〈詩〉海;【機械工程】波...
  • impedance : n. 【物理學】阻抗。 acoustic impedance聲阻抗。
  1. Coaxial connectors for receiving aerials ; connectors for 75 ohm surge impedance

    接收天線用同軸連接件. 75歐姆浪涌阻抗用接連件
  2. However, by the time a lightning strike has traveled through the distribution network, surge arrestors will have dissipated a proportion of the charge, network impedance will have shaped the impulse and the residual energy can be represented in terms of its waveshape, and its peak current which is what will be present at a service entrance

    然而,雷擊經過電力網路進行傳送以後,避雷放電器會將一部分能量泄放掉,網路的阻抗也會對電涌進行修整,而殘余的能量將可以以它的波形來體現,其峰值電流也就是建築物進入端將會出現的情況。
  3. Used regulations method calculating, analyzing and comparing the lightning protection performance with field data for the line firstly, . then put forward more reasonable model ( distributing parameter model ) to calculate the surge impedance of tower combining the existing model and validate by emtp, furthermore studied the striking distance factor based on electromagnetism

    首先利用規程法對線路的耐雷性能進行計算、分析,並與現場數據比較;同時結合目前對桿塔波阻抗的研究方法,提出一種更合理的桿塔波阻抗計算模型?桿塔分佈參數模型,並利用emtp進行模擬計算和驗證。
  4. The theoretic calculating method of the maximum and the minimum water level in the differential surge tank has been derived firstly. also the explicit method of calculating surges in the differential surge tank has been deduced firstly by use of thaler series expansion. the calculating method of section of the well and the effective impedance hole in the surge tank has been gived

    根據差動式調壓室的基本微分方程,首次推導出了差動式調壓室涌浪幅值的理論計算公式;並同樣利用泰勒級數展開方法推導出了差動式調壓室水位波動的顯式計算式;導出了差動式調壓室大井面積和有效阻抗孔面積的計算方法。
  5. The model considers peak value of lightning current, tower grounding resistance, tower style, line surge impedance, power frequency voltage and distance between towers

    模型中考慮了雷電流幅值、桿塔沖擊接地電阻、桿塔具體形狀、尺寸、桿塔波阻抗、工頻電壓及檔距等因素的影響。
  6. For bus system installation, the focus is put on cable selection principle, installation process and antinoise measure ; for security protection equipment installation, the intrinsic safety concept, installation method equipment selection and installation under two electric power supply modes ( entity concept and fisco model ) and the bus system protection against surge voltage are illustrated ; for network component installation, the selecting, installing and integrating methods of general purpose terminators, repeaters, link equipment, bus power supply and impedance module are described

    在總線電纜的安裝方面,著重討論了電纜的選型原則、安裝方法和抗噪防擾措施;在安全保護設備安裝方面,介紹了總線系統中本質安全的概念、安裝方法、兩種供電方式(實體概念和fisco模型)下設備的選擇與安裝以及總線系統浪涌電壓的保護和設備安裝方法;在網路元件的安裝方面,主要列舉了通用終端器、中繼器、鏈路設備、總線電源及其阻抗模塊等的選擇、安裝和集成方法,為總線系統的安裝提供了可以借鑒的實用經驗。
  7. Firstly, we analyze the transient and steady character of single phase high - impedance grounding fault. secondly, based on wavelet analysis on checking mutational signal and direction high frequency protection theory, utilizing zero sequence current and module current, this paper provides a new scheme including fault starting element, fault phase selection element, directional element and main criterion. this scheme can bear high impedance and is immune to system surge and frequency warp, which gets over the shortcoming of the lack of sensitivity

    由於現有的保護方案無法快速有效地切除此類故障,本文在詳細分析了單相高阻接地故障的穩態和暫態特性的基礎上,從小波分析原理出發,利用小波變換檢測突變信號的原理,以零序電流、模電流等為研究對象,結合方向高頻保護的原理,設計了一套包含啟動元件、選相元件、方向元件、主保護的保護新方案。
  8. Mutual surge impedance

    互感波動阻抗
  9. Characteristic surge impedance

    特性浪涌阻抗