synchronous motor-generator 中文意思是什麼

synchronous motor-generator 解釋
同步電動發電機
  • synchronous : adj. 同時的,同期的;【物理學】同步的。adv. -ly
  • motor : n 1 原動者;原動力。2 發動機;馬達;電動機;【火箭】助推器;汽車。3 【解剖學】運動肌;運動神經。a...
  • generator : n 1 產生者,生殖者,創始者。2 發電機,發生器。3 【音樂】基礎低音。4 = generatrix a D C generator...
  1. Compared to the traditional converter, the new one can transform electric power from a static part to a rotary part without an electrocircuit connection, which makes the contactless power transform come true. one application of this converter is to supply a steady and regulable excitation circuit for synchronous generator by integrated its second winding with the motor while its primary winding is static. the thesis gives two methods of the rotating converter design paticullarly : flyback and fullbridge, and explains how the circuits are designed

    通過理論分析、模擬分析和實驗驗證,得出這兩種旋轉變換器都能進行感應電能傳輸,但它們的傳輸功率是不同的,反激式旋轉換器最大隻能傳輸幾十瓦功率的感應電能,因此只能用在感應電能傳輸較小的場合,或者信號傳輸的場合;而全橋式旋轉變換器能傳輸較大的功率,可用於電機的新型無刷勵磁方案中。
  2. Secondly, to achieve the independent regulation of active and reactive power output from the generator side which is designed for the purpose of tracing the maximum wind - energy capturing. the paper has analyzed the mathematic model of the ac excited doubly - fed machine and the stator field orientation control strategy of the motor as vscf wind power generator. thirdly, it has put forward and designed the dual pwm converter with the capacity of energy flowing bidirectional aimed at the demand of rotor energy bidirectional flow. the author constructed reliable and integrated experimental system and did a series of experimental study including no - load, cutting - in network and power generation at, below and above the synchronous speed

    論文首先分析了風機運行特性及其最佳風能利用原理,通過模擬及實驗驗證了採用直流電機的輸出特性模擬風力機的最大輸出功率曲線的可行性,並給出了模擬系統的硬體結構;然後為了實現交流勵磁發電機有功、無功功率獨立調節機理,分析了交流勵磁雙饋發電機的數學模型和在追蹤最大風能捕獲變速恆頻風力發電時必需的定子磁鏈定向矢量控制策略;針對雙饋發電機轉子能量雙向流動的要求,提出並設計了具有能量雙向流動能力的雙pwm交流勵磁用變頻器;最後為實現從理論到實踐的全面研究,研製出了一套小功率完整的雙pwm變頻器交流勵磁的雙饋風力發電機實驗系統,進行了空載、並網、同步速及上、下的發電運行等一系列的運行實驗;所完成的模擬和實驗研究均驗證了理論、模型和控制策略的正確性、可行性。
  3. This model is composed of a synchronous generator and two dc motor

    以一臺同步發電機作為模擬的電源,兩臺直流電動機作為電動車的后輪驅動電機。
  4. The influence of both synchronous generator and the distance from local power plant to load bus on load modeling are analyzed. when the influences are not negligible, the composite induction motor load model can not effectively describe the actual load. besides, the identifiability in this case is analyzed

    分析了同步發電機在綜合負荷中所佔的比例、地方發電廠離負荷母線的距離對負荷建模的影響,指出當同步發電機影響必須計及時,通常的感應電動機綜合負荷模型就不能正確描述區域負荷,並對由此引起的可辨識性及建模問題作了分析。
分享友人