transformer active power 中文意思是什麼

transformer active power 解釋
變壓器有功功率
  • transformer : n. 使變化的人[東西];【電學】變壓器;變換器;互感器。 polarity of transformer 變壓器繞線方向。
  • active : adj 1 活動的,有活動力的;【生物學】活性的;【電學】有功的;【無線電】有源的;【物理學】放射性的...
  • power : n 1 力,力量;能力;體力,精力;(生理)機能;〈常 pl 〉才能。2 勢力,權力,權限;威力;政權;權...
  1. First the paper use the different four network operating condition as the primary given conditions and set the 330 / 220kv transformer tap changer position in the standard position, adding the paralleled capacitor bank sets one by one into the network to change the amount of the input reactive power, thus obtained four sets of the 330kv and 220kv bus voltage and the active and reactive power losses changing curves

    進而研究了在每一確定並聯補償電容器組投入量條件下,隨聯變調壓檔位變化而產生出的一組並聯補償量、母線電壓與損耗的變化曲線。進而選出了隴南電網在四種選定電網運行方式下、有功損耗最小條件下的最優綜合控制組合曲線。
  2. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及電網潮流,總結出了如下規則:隴南電網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償電抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內無功潮流分佈合理、各變電站母線電壓在理想的范圍內時電網有功損耗最小,從而也提高了電網安全運行水平及供電質量。
  3. In order to improve the behavior of transformer protection that is incomplete at present in distinguishing magnetizing inrush current from fault current, the paper puts forward a kind of new principle of transformer differential protection after analyzing the characteristic of magnetizing inrush and active power consume of transformers. this protection uses differential protection based on positive sequence active power as a criterion to discriminate internal faults from magnetizing inrush, and ratio restraint differential current protection as a signal to touch off the protection

    針對當前電力系統中變壓器保護由於勵磁涌流鑒別理論不完善而導致的誤動率相對較高的問題,論文在分析了變壓器勵磁涌流特性和有功損耗的基礎上,提出了用變壓器正序有功功率差動作為區別勵磁涌流和故障電流的判據,並以成熟的比率制動差流保護作為內外部故障判據的變壓器主保護。
  4. Active electronic current transformer is a new type of high - voltage apparatus for current measurement of power system, which is a complete combination of optical electronic technology with fiber optic sensing technology

    電子式電流互感器是利用光電子技術和光纖傳感技術來實現電力系統電流測量的新型互感器。
分享友人