voltage to neutral 中文意思是什麼

voltage to neutral 解釋
對中點的電壓
  • voltage : n. 【電學】電壓,電壓量,伏特數。 the working voltage (電氣的)耐壓限度。
  • to : adv 到某種狀態;〈特指〉到停止狀態;關閉。 ★也常和動詞結合,略去其後賓語,而構成成語: The door i...
  • neutral : adj 1 中立的;中立國的。2 不偏不倚,公平的;中庸的;中間的;不倫不類的,不明確的;不鮮艷的,暗淡...
  1. To resolve the situation that the sensitivity of present ground fault protection schemes is low for the large - sized hydro - generators, a kind of protection scheme based on the fault component of third - harmonic voltage and two kinds of protection scheme based on the fault component of zero - sequence voltage at the terminals and neutral are developed, and they can obtain higher sensitivity and reliability and provide 100 % protection for the stator windings. the influence of noise on the stator ground fault protection based on the local modulus maximum of wavelet transform is analyzed

    針對目前大型水輪發電機定子繞組單相接地保護靈敏度偏低的問題,通過分析單相接地故障后機端和中性點零序電壓的變化特點,提出了一種基於機端和中性點三次諧波電壓故障分量和兩種基於機端和中性點零序電壓故障分量的高靈敏度、高可靠性保護方案,並實現定子繞組的100 %保護。
  2. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  3. Firstly the paper summarized the methods of passing over of neutral section and its application status quo in the domestic and oversea. as the research object of the paper, the reason of over - voltage caused by the method of ground transfer by vacuum breaker is analyzed though simulation and experiment. and based on the analyze, a method of automatic passing over of neutral section using thyristor vale to controlling the phase of electric power is presents

    本文首先綜述了國內外自動過電分相的方式及應用研究現狀,並以地面開關轉換方式為本文的研究對象,通過模擬和實驗,分析了這種方式產生過電壓的機理,以此為基礎,提出了以晶閘管閥控制電網電源投入時刻的自動過分相方案。
  4. Line - to - neutral voltage in a 3 - phase, 4 - wire, y - connected generator, line - to - neutral voltage is the voltage between a phase and the common neutral where the three phases are tied together

    相電壓在三相四線星形連接的發電機中,相電壓是指三相連接點與每相之間的電壓。
  5. According to zero sequence voltage distribution from system zero sequence impedance to shunt reactor zero sequence in zero sequence circuit, the zero sequence voltage at the terminal of shunt reactor and the zero sequence compensating voltage at neutral are compared in the scheme

    即根據零序網路中零序電壓在系統零序阻抗和電抗器零序阻抗上的分佈情況,通過直接比較電抗器首端零序電壓與補償到電抗器末端中性點的零序補償電壓的幅值大小,來判別電抗器匝間故障。
  6. Firstly, this paper introduces the asynchronous motor model, and compares it with the dc motor ’ s. then the paper studies the principle of vector control, and proposes an improved current model of rotor flux observer. this paper also studies the three - level inverter ’ s topology, working principle, the neutral - potential unbalance mechanism and its controlling strategy. the paper especially studies the svpwm in details. the interface between the vector control and the three - level inverter is studied in details, including the generation of reference voltage vector, its judging of the sector and triangular regions, and the working mechanism after it sent into three - level inverter. when synthesizing the reference voltage vector, select the vector which only includes p and o states as the starting vector, thus eliminate the vector shift problem when sector changes. this paper fully takes advantages of the powerful functions of matlab / simulink to set up the simulation model. this construction is very explicit. the simulation results verify the inverter voltage output is correct, the rotor flux is steady, the asynchronous motor ’ s dynamic and steady state performances and speed modulation are excellent

    本文首先介紹了異步電機的數學模型,在此基礎上將異步電機的數學模型與直流電機的數學模型進行了比較;然後介紹了矢量控制的基本原理,採用了一種改進的轉子磁鏈電流型觀測模型;對三電平逆變器的電路拓撲、工作原理、中點電位不平衡的機理及控制方法進行了介紹,詳細分析了空間矢量脈寬調制策略。本文對異步電機的矢量控制與三電平逆變器之間的介面進行了詳細的研究,包括:參考電壓矢量的形成、所落扇區與具體小三角形區域的判斷、送入逆變器之後的工作機理。在參考電壓矢量的合成時,選擇只包含p 、 o狀態的空間電壓矢量作為起始矢量,解決了扇區切換時的矢量突變問題。
  7. According to the practice on gezhouba to shanghai hvdc transmission project and in consideration of condition on three gorges hvdc project, some suggestions on protection of overvoltage and insulation coordination for outer insulation, against pollution - wet, dc neutral bus over - voltage and dc & ac filter are technically presented. it may be a reference in design of three gorges converter station

    根據葛南直流工程的經驗並結合三峽工程的情況,在換流站的外絕緣、直流耐污濕技術、直流中性母線過電壓防護、交直流濾波器的過電壓防護等方面提出了過電壓和絕緣配合的技術要求,供設計參考。
  8. The generators are of three - phase four - wire type, making use of star connection with neutral point. the rated line voltage is 400v. phase voltage 230v. frequency 50hz, power factor 0. 8 ( lag ). it can provide 60hz and the other voltage ' s generator according to necessary

    本發電機為三相四線制,採用帶有中性點的星接法,額定電壓為400伏,相電壓為230伏,頻率50赫,功率因素0 . 8 (滯后)根據用戶需要,也可提供60赫及其它電壓值的發電機。
  9. This paper analyses the reason that neutral voltage is not zero when linear three - phase system load connects to three - phase three - wire system source in y connection. the resolution is also given

    摘要分析了線性三相負載y聯接在三相三線制電源時,中點電位不為零的原因,並通過計算進行了驗證,給出了解決的方法。
  10. According to the present actual underground power system which neutral point is grounded through arc suppression coil in many supper big shaft, the development history and present situation of synthetic protection system used in hv flameproof switchgear are reviewed, and on the basis of analyzing the problems existed in high voltage flameproof switchgear, the selective leakage protective method based on the detecting harmonic direction of zero sequence current as well as the value of zero sequence voltage is proposed in this paper, and at the same time, harmonics extracting schematic and transforming circuit are also designed

    本文深入系統地研究了基於intel80c196kb單片機控制的6kv防爆開關綜合保護系統,主要內容如下:針對大型及特大型礦井供電系統中性點普遍採用消弧線圈接地方式的現狀,回顧了國內外礦用高壓防爆開關保護系統的發展歷史,分析了目前國內高壓饋電開關保護系統所存在的問題,提出了「基於零序電壓基波啟動,五次諧波功率方向比較」的選擇性漏電保護原理,設計了相應的五次諧波提取電路和功率方向鑒別電路。
  11. The result of simulation and test verified that this algorithm is simple to be carried out, and harmonics in output waveform are small, and neutral point voltage can be controlled very well, and narrow pulse problem is solved as well

    模擬和實驗結果表明,該方法實現簡單,輸出波形諧波含量小,中點電位得到很好的控制,並較好地解決了窄脈沖問題。
  12. Based on the project of " the developing of high voltage thyristor vale for auto - passing over neutral section of traction power supply system ", funded by railway ministry of china, the paper researches the application of high voltage thyristor vale to automatic passing over of neutral section equipment and solves its application design and controlling problem

    本文以「牽引供電系統晶閘管閥自動過分相裝置研製」項目為基礎,研究了高壓晶閘管閥在牽引供電網自動過分相中的應用,解決了高壓晶閘管閥在牽引供電網自動過分相裝置中的應用設計及其控制問題。
分享友人