zero-phase-sequence system 中文意思是什麼

zero-phase-sequence system 解釋
零序系統
  • zero : n (pl zeros zeroes)1 【數學】零;零號。2 零位;零點,起點;(溫度表的)零度,冰點;座標原點;無...
  • phase : n 1 形勢,局面,狀態;階級。2 方面,側面。3 【天文學】(月等的)變相,盈虧;【物、天】相,周相,...
  • sequence : n 1 繼續;接續;連續。2 順序;程序;次第;關系;關聯。3 後果;結果;接著發生的事;後事;後文。4 ...
  • system : n 1 體系,系統;分類法;組織;設備,裝置。2 方式;方法;作業方法。3 制度;主義。4 次序,規律。5 ...
  1. It includes four criterions of locating fault point ? “ transient zero sequence current amplitude law ”, “ stable base wave zero sequence current phase law ”, “ stable seventh harmonic zero sequence current phase law ” and “ s injection law ”. pointing out how the law locate the fault point to minimal fault section by applying these criterions gradually. the law will not only make up the blemishes existing in current methods for single - phase fault location in small current grounding system, but also locate the fault point to minimal fault isolating unit on fault line

    該方法通過將所包含的四個定位判據- 「暫態零序電流幅值法」 、 「穩態基波零序電流方向法」 、 「穩態7次諧波零序電流方向法」和「 s信號注入法」 -進行有選擇地遞進使用,不僅有效彌補了目前已有小電流接地系統單相接地故障選線的缺陷,更將故障定位在故障線路最小故障區段。
  2. Unified power flow controller ( upfc ) is one of the most powerful and most promising controllers of facts. if we use upfc to control the transmission parameters, terminal voltage, line impedance and phase angle in normal situation and use it to compensate zero sequence and negative sequence currents when one of transmission lines is cut off, we can implement two phases operating in high voltage transmission lines, which can improve stability and reliability for the transmission system

    統一潮流控制器( upfc )是功能最強、最具發展潛力的靈活交流輸電系統( facts )控制器之一,如果在常規條件下,用upfc實現輸電線路的電壓調節、移相、潮流控制、阻尼振蕩等功能,在發生單相永久性接地或單相斷路故障時,由傳統的三相跳閘改為單相跳閘,用upfc的並補來濾除兩端系統的零序和負序電流,用upfc的串補來提高輸電線的傳輸功率,以實現兩相長期運行,那麼輸電系統的穩定性、可靠性將大大提高。
  3. Firstly, we analyze the transient and steady character of single phase high - impedance grounding fault. secondly, based on wavelet analysis on checking mutational signal and direction high frequency protection theory, utilizing zero sequence current and module current, this paper provides a new scheme including fault starting element, fault phase selection element, directional element and main criterion. this scheme can bear high impedance and is immune to system surge and frequency warp, which gets over the shortcoming of the lack of sensitivity

    由於現有的保護方案無法快速有效地切除此類故障,本文在詳細分析了單相高阻接地故障的穩態和暫態特性的基礎上,從小波分析原理出發,利用小波變換檢測突變信號的原理,以零序電流、模電流等為研究對象,結合方向高頻保護的原理,設計了一套包含啟動元件、選相元件、方向元件、主保護的保護新方案。
  4. This paper brings forward that asvg is capable of compensating harmonic, negative sequence and zero sequence currents. so asvg can synchronously compensate the reactive current and harmful currents in three - phase four - wire unbalanced system

    本文提出靜止無功發生器還具有抑制諧波和濾除負序、零序電流的能力,從而可以用於對三相四線制不平衡系統同時進行無功補償和有害電流濾除。
  5. In the electric power system of neutral point effectively, if parameter is not symmetric, the zero - phase - sequence current will appear

    在中性點有效接地系統中,如果參數不對稱就會產生零序電流。
分享友人