劑量值 的英文怎麼說

中文拼音 [liángzhí]
劑量值 英文
dose value
  • : Ⅰ名詞1 (藥劑; 制劑) a pharmaceutical or other chemical preparation 2 (某些有化學作用的物品) a...
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • 劑量 : [物理學] [醫學] dosage; dose; dosis劑量槽 dosage bunker; 劑量測定(法) dosimetry; health work; ...
  1. Some problems in the action level and dose assesment of radon

    氡防護標準和評價中得注意的幾個問題
  2. 5. the osl dating of 37 samples of loess in weihe river basin by sar and multiple aliquot methods, indicates that sar protocol appears to be applicable to loess and appropriately correcting for sensitivity changes within the regenerated curves, however, there are major difference between the irsl and post - ir osl de determinations that suggest that sensitivity changes relating to either ( or both ) natural signals may not be correctly monitored

    同時,用單片再生法測小干3ha的黃土細顆粒樣品, slsl 、 irsl和post irosl測的年代在誤差范圍內基本相同,接近預估年代;對於3ha ? 10ha的黃土細顆粒樣品,一般post osl測的年代更接近預測;對于大於10ha的樣品,一般irsl測的年代普遍太小,多數blsl年代也偏小,而p 。
  3. In order to elaborate the app licability of osl to loess, especially single aliquot regenerative protocol ( sar ), involving stimulation of the same disc with an infra - red laser diode followed by blue leds to polymineralic fine - grains of loess, such explanations as light bleaching, preheat, anomalous fading, prior - ir exposure were investigated in this paper. for drawing adequate coarse grains from loess, quartz and feldspars, as well as loess, were etched by hydrofluoric acid and fluorosilicic acid. the sequence of ages of holocene loess in weihe rivier basin has been established by single - aliquot ( sar ) and multiple - aliquot using fine - grains and sar using coarse - grains

    本文通過渭河流域全新世黃土的光曬退實驗,地表黃土樣品的d _ e測定,細顆粒單片的預熱、反常衰退、紅外暴露實驗,說明釋光測年在全新世黃土中應用的可行性及單片再生法( sar )在黃土細顆粒中的適用性;為了從黃土中分離出足夠的粗顆粒,進行了純石英和長石的氫氟酸( hf )和氟硅酸( h _ 2sif _ 6 )溶蝕實驗,黃土粗顆粒石英溶蝕分離實驗;通過細顆粒單片、多片的blsl 、 irsl和post - irosl ,熱釋光,及粗顆粒石英的blsl的年代測定,選擇適于全新世黃土的釋光測年方法,並建立了渭河流域全新世黃土的年代序列。
  4. In the experimental studies on the behaviors of helium in aluminum, ion implantation technique was adopted to introduce helium with different energies, doses and distributions into some specimen of monocrystal, polycrystal, and preferred orientation as to the structure of aluminum. the energies varied in the range of 50ev to 4. 87mev. the corresponding helium peak depths by trim simulation varied in the range of 16 angstrom to 20. 7 microns

    在金屬鋁中氦行為的實驗研究中,首先用離子注入技術在單晶、多晶以及擇優取向的鋁樣品中引入不同能和濃度分佈的he原子,能范圍從50ev 4 . 87mev , trim模擬的he濃度峰的深度范圍為16 (
  5. Inspection, test, construction, and performance requirements for direct reading electrostatic electroscope type dosimeters

    直接和間接示石英纖維袖珍計的檢驗和測試驗規范
  6. ( 2 ) the reaction factors optimized by orthogonal tests are : the emulsion polymerization temperature is 60, the reaction time is 3 hours, the amount of emulsifier is 8wt %, the hydrophile lipophile balance ( hlb ) value of emulsifier is 15, the stirring speed is 4000r / min, the dropping speed is 1. 1g / min

    用正交實驗確定的最佳聚合反應工藝參數為:水解溫度60 ,水解聚合時間3h ,乳化8wt ,復合乳化hlb為15 ;攪拌速度為4000r min ,滴加速度為1 . 1g min 。
  7. International standard in the 1990 recommendations of the international commission on radiological protection icrp publication no. 60, the recommended dose limits for exposure associated with practice are as follows

    國際放射防護委員會在其一九九零年的建議書第60號刊物內,對于因活動而引致的輻射照射,建議的如下:
  8. Soil improvers and growing media - determination of a quantity

    土壤改良和培養基.測定
  9. Predictive value of transvaginal sonography for systemic methotrexate treatment of unruptured ectopic pregnancy

    經陰道超聲對異位妊娠單氨甲喋呤治療結果的預測價
  10. Correlation between signal cutoff ratios of anti - hcv enzyme immunoassay and their true positivity in blood donors

    獻血員丙型肝炎病毒抗體酶免疫法檢測試的測與其真陽性的相關性
  11. For the stochastic effect, a threshold does not exist, but the probability of having detrimental effect is proportional to the dose absorbed

    而後者沒有,但效應出現的機會率與有關。
  12. An analytical mosfet threshold voltage shift model due to radiation in the low - dose range has been developed for circuit simulations. experimental data in the literature shows that the model predictions are in good agreement. it is simple in functional form and hence computationally efficient. it can be used as a basic circuit simulation tool for analysing mosfet exposed to a nuclear environment up to about 1mrad. in accordance with common believe, radiation induced absolute change of threshold voltage was found to be larger in irradiated pmos devices. however, if the radiation sensitivity is defined in the way we did it, the results indicated nmos rather than pmos devices are more sensitive, especially at low doses. this is important from the standpoint of their possible application in dosimetry

    該模型物理意義明確,參數提取方便,適合於低輻照總條件下的mos器件與電路的模擬。並進一步討論了mosfet的輻照敏感性。結果表明,盡管pmos較之nmos因輻照引起的閾電壓漂移的絕對更大,但從mosfet閾電壓漂移的擺幅這一角度來看,在低輻照條件下nmos較之pmos顯得對輻照更為敏感。
  13. Clinical dosimetry - part 5 : application of x - rays with peak voltages between 100 and 400 kv in radiotherapy

    臨床.峰電壓為100至400kv的x射線放射療法
  14. 3 for example, if ambient gamma radiation is the only factor contributing to the radiation dose to a person, this dose of 5000 microsieverts may be reached when the ambient gamma dose rate is 1000 microsieverts per hour more than 3000 times above background and lasts for 5 hours ; or when the dose rate is 200 microsieverts per hour more than 600 times above background and lasts for 25 hours

    3 .例如,假若環境伽瑪率持續高達每小時1000微希沃特超過本底3000倍,則在5小時內,因為環境伽瑪輻射所引致的總便可能達到上述的5000微希沃特。若環境伽瑪率每小時200微希沃特超過本底600倍,則個人須持續受此輻射影響25小時,所受的總方可達到上述5000微希沃特。
  15. The total dose increases continuously from the time of arrival of the fallout toward the limiting(infinite time)value.

    從沉降物抵達時開始就不斷上升直到極限(無限時間)。
  16. The bleaching experiment of loess by iodine tungsten lamp and the equivalent dose ( de ) of loess estimated by sar from the earth ' s surface indicate that loess can be easily bleached by sunlight, and osl is suitable for the dating of loess. 2. equivalent dose estimated by sar, when each natural or regenerated dose osl measurement is corrected for changes in sensitivity using the osl response to a subsequent test dose and the recycling ratio is around 1, implies that sensitivity changes have been properly corrected

    用單片再生法( sar )測定黃土樣品的d _ e時,用固定的實驗釋光信號校正後,再循環比( recyclingratio )都在1左右,說明對釋光靈敏度的變化起到了很好地校正作用;校正後, ogy再生釋光信號與自然信號的比率都在5以下,信號的回復可以忽略不計。
  17. Dose limit refers to the maximum allowable dose arising from exposure received by a worker in practice

    一八限度:指人員因輻射作業所受之曝露,不應超過之劑量值
  18. 3. dna double strand breaks ( dsbs ) induced by ion beams of gel electrophoresis experiment has shown positive linear with dose, i. e., double strand breaks will increase as the dose increased

    分子生物學技術? ?電泳技術分析結果表明,離子輻射造成的dna雙鏈斷裂( dsb )與粒子呈線性正相關關系,即隨著粒子劑量值增大, dsb也逐漸上升。
  19. With the data from all kinds of inspecting methods, the system can detect the error on time and direct it the whole system has nine field detecting subsystem and one hangzhou host system

    能及時發現輻射水平的異常,並估算附加劑量值。該系統包括9個現場監測站(其中一個還是數據匯總站中心)和一個杭州中心站。
  20. At last, the heart beating speed and blood pressure of taxi drivers and the response time are measured after the vibration duration is 0, 2, 4, 6, 8, 10 hours. the phenomena that response time is longer and longer, the rate of heart beating is faster and faster and blood pressure raises firstly and then decreases are founded. the drivers will suffer from fatigue in about 8 hours

    最後,本論文在國內外首次對出租車駕駛員工作0 、 2 、 4 、 6 、 8 、 10小時后的心跳速度和血壓這兩個生理指標及反應時間進行了測,並發現隨著工作時間的增加,出租車駕駛員的反應時間逐漸加長,心跳速度逐漸增加,駕駛員的血壓先增加后降低;發現出租車駕駛員大概在工作8小時之後疲勞,與駕駛員的主觀感覺完全吻合;通過計算,職業駕駛員疲勞時對應的估計振動劑量值為: 11 . 12ms - 1 . 75 ,依此可以將此研究成果推廣到其他類似出租車駕駛員的職業駕駛員的疲勞判別中,從而可以制定出更合理的作業時間。
分享友人