排量式增壓器 的英文怎麼說

中文拼音 [bèiliángshìzēng]
排量式增壓器 英文
displacement blower
  • : 排構詞成分。
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : 名詞1 (樣式) type; style 2 (格式) pattern; form 3 (儀式; 典禮) ceremony; ritual 4 (自然科...
  • : 壓構詞成分。
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 排量 : aerodynamic volume displacement
  1. Air filtration portfolio, air filters, valve, oil mist machine, filter valve, oil mist separator, micro - mist separator, stability activated solenoid valve, pressure gauge, micro - valve and vacuum valves, links the release of the closure - pressure valves, and pipe connection, a one - way valve, t - shelves, shelves, brackets, diaphragm - type flow switches, blades type flow switches, further growth actuator, the valve lock, precision valve, pressure switches, mechanical pressure switches, pneumatic control ratio positioning devices, and electric - gas ratio positioning devices, and telecommunications - pressure converters, electro - pneumatic proportional valve, filter valve, shuttle valve, gas - electric relay and gas indicator, delay pneumatic valve and cylinder fcl, plumbing fcl, mufflers and exhaust cleaner, the excess flow valve with silencer, a one - way valve, rapid valve, rapid joints, rapid valve with fcl, rapid joint sub - cluster gas, micro joints, gas pipes, pipe from the devices, and helical coils, pipes, channels, scissors, multiple fastener, high - speed rotary joint, 10000 threaded joints, and insert the tube joints, rotary joints began, 68. 25 rapid joints and hoses, hose fittings and rapid non - electrostatic

    空氣過濾組合空氣過濾閥油霧過濾減閥油霧分離微霧分離穩定啟動電磁閥力表微型減閥減氣閥三通釋放截流閥力開關管接頭單向閥t型隔板隔板托架膜片型流開關漿葉型流開關速繼動鎖定閥精密減力開關機械力開關氣控比例定位電-氣比例定位電訊號-氣轉換電-氣比例閥過濾減閥梭動閥氣-電繼電氣源指示氣動延時閥氣缸限流管道限流消聲氣潔凈限流閥帶消聲單向止回閥快速氣閥快速接頭快速氣閥帶限流快速接頭集束分氣微型接頭氣喉管喉管脫離螺旋管管管道剪刀多管扣件高速旋轉接頭萬用螺紋接頭插入管接頭旋緊鎖接頭難燃性快速接頭和軟管不帶靜電快速接頭和軟管
  2. The research results show that the counter - flow condensers have a better performance than that of other arrangements in single - circuit condensers, and that branch flow should be adopted in multi - rows condensers to decrease the pressure drop and increase the heat transfer capacity, and that the influence of gravity force can not be ignored, and that there must be an optimum refrigerant mass flow which can make the condenser perform best when the air velocity is constant while there must be an optimum air flow which can make the condenser perform best when the refrigerant mass flow is constant

    研究結果表明,單迴路冷凝中,逆流布置換熱效果最好,叉流其次,順流最差;多管冷凝應盡可能採用分流方,以減小降,強換熱;布置冷凝流程時,重力的影響不可忽略;當風不變時,必然存在一最佳製冷劑流使冷凝性能達到最佳;當製冷劑流保持不變時,也相應存在一個最佳風使冷凝性能最佳。
分享友人