放射測量計 的英文怎麼說

中文拼音 [fàngshèliáng]
放射測量計 英文
electroradiometer
  • : releaseset freelet go
  • : Ⅰ動詞1 (用推力或彈力送出) shoot; fire 2 (液體受到壓力迅速擠出) discharge in a jet 3 (放出) ...
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : Ⅰ動詞1 (計算) count; compute; calculate; number 2 (設想; 打算) plan; plot Ⅱ名詞1 (測量或計算...
  • 放射 : radiate; emit; blas; radiation; emission; shooting; shedding; abjection; emanation; effluence
  • 測量 : measure; survey; gauge; meter; measurement; measuring; surveying; mensuration; metering; gauging;...
  1. Choosing y type reflection fiber optic detector, this thesis create a tiny displacement - detecting sensor that is made up of led ( light emitting diode ), fiber optic detector, electric eye, lock - in amplifier, display and other electro circuits

    本論文採用y型反式光纖探頭設製作了一種微位移裝置,它主要由發光二極體、光纖探頭、 、鎖相大器、顯示器及相關電路組成。
  2. This was expanded into the environmental radiation monitoring programme in 1987, with the objective of measuring the environmental radiation levels in hong kong prior to and after the operation of the guangdong nuclear power plant at daya bay. air, water, soil and food samples are regularly collected for radioactivity measurement

    劃的目的,是廣東大亞灣核電廠投產前後香港環境中的輻水平,而工作項目則包括定期?集空氣、水、土壤和食物的樣本以及這些樣本的性。
  3. General requirements of quality assurance program for effluent and environmental radioactivity monitoring at nuclear facilities

    核設施流出物和環境性監保證劃的一般要求
  4. Medical electrical equipment. part 2 : particular requiremet for the safety of patient contact dosemeters used in radiotherapy with electrically connected radiation detectors

    醫療用電氣設備.第2部分:用電連接器的治療法定病人接觸劑安全性的特殊要求
  5. Design of internal dosimetry programs

    內部劃設
  6. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - dosimetry for radiation protection over the energy ranges 8 kev to 1, 3 mev and 4 mev to 9 mev

    校準劑和劑強度定作為光子能函數靈敏度用x和基準線.能范圍在8kev - 1 , 3mev和4mev - 9mev保護用
  7. Graduation and calibration of surveying instrument for liquid scintillation counter by using radioactivity certified reference material, and the accurate measurement of ( superscript 3 ) h or ( superscript 14 ) c have been finished

    摘要利用性標準物質刻度和校準液閃數器儀器,並完成(上標3 ) h和(上標14 ) c活度的精確
  8. Surface materials for use in radioactive areas - methods of measuring and evaluating the decontamination factor

    性區域用表面材料.第1部分:去污染系數的算方法
  9. This paper uses methods of mathematical statistics to quantitatively measure the concentration and dispersion degree of spatial pattern and evaluate the convenience degree of spatial connection of wuhan in deviation ratio, compactness ratio, dispersion ratio, radial shape index and transportation distance

    摘要運用數理統方法,從偏離度、緊湊度、離散度、狀指數及出行距離等方面,對武漢市建成區幾何形狀的集中、分散程度和空間聯系的便捷程度進行定度評價。
  10. Determination of the detection limit and decision threshold for ionizing radiation measurements - fundamentals and applications to counting measurements on filters during accumulation of radioactive material

    電離輻限和判斷閾的確定.基本原則及對材料累積過程中過濾器的應用
  11. According to the principle of correlation detection, an automatic measurement system for extinction ratio of polarizer consisted of monochromator and dsp lock - in amplifier and compurer is designed not only to eliminate the influence on measurement accuracy caused by drift of intensity of light source but also to obatain approximate extinction spectrum

    摘要基於相干檢原理設了一套由單色儀、數字鎖相大器和算機聯合使用的透式偏光鏡消光比智能化試實驗系統,採用雙頻雙光路分光單探器接收鎖相大器分離信號比對法進行源補償,克服了光源光強漂移所帶來的影響;實現了可見光區消光比的精確自動,而且可以得近似的消光光譜。
  12. Nuclear energy - measurement of radioactivity in the environment - bioindicators - part 1 : guidance for the design of sampling programs

    核能.環境中性的.生物指示劑.第1部分:取樣程序設的指南
  13. Secondly, basing on the theory of on - off gain of small signal, the raman gain coefficient for frequency shift between 0. 5 and 20 thz of standard sigle mode optical fiber is measured by pump - probe method through a super luminescent diode ( sld ) as a broadband small signal probe source. thirdly, numerical simulation analysis of gain characteristic of raman fiber amplifier for c band wdm signal light is made according to the raman gain coefficient of the fiber measured before through target and four rank runge - kutta method. at the invariability of wavelength and maximum power of each of two pumps, schematic of powers of two pumps for best flatness on c band wdm optical gain was found out, at the same time, the factors of resulting in gain saturation is analyzed, too

    本文首先應用經典的電磁理論對拉曼光纖大器的工作機制進行了分析,然後,根據小信號理論推導出的開關增益求出了光纖拉曼增益系數的表達式,採用泵浦-探波的方法,利用超輻激光二極體( superluminescentdiode簡稱sld )作為探光源,了所用標準單模光纖頻移為0 . 5 - 20thz的拉曼增益系數,之後根據所得的光纖的拉曼增益系數譜對應用該類光纖構成的大c波段wdm光信號的拉曼光纖大器的增益特性採用打靶法和四階龍格- - -庫塔進行了數值算,在給定了兩個泵浦光源的波長和最大功率后,找出了反向泵浦情況下使c波段wdm光源增益最平坦的兩個泵浦的各自最佳功率,同時也分析了導致信號光飽和的原因。
  14. Methods receptor binding assay ( rba ) was adopted to measure the distribution of pgr and er in liver cancer and tissue in its vicinity in 63 patients with primary liver cancer ( plc ) undergone laparotomy and in non - tumor liver tissue in 7 cases with gastric carcinoma

    方法採用性配基結合分析法( rba )定了63例行手術切除的肝癌組織、癌周組織及7例非肝癌肝組織的雌、孕激素受體的含並結合臨床資料進行統分析。
  15. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - radiation characteristics and production methods

    校準劑和劑強度定作為光子能函數靈敏度用x和基準線.第1部分:特性和產生方法
  16. The design has the characteristics of high accuracy, low cost and wide measuring range, and thus offers a reference for further developing practical multiphase flowmeters of non - radioactivity pollution, low press loss and non - moving components

    該方案具有可靠、成本低、范圍廣的優點,為研製無性、無可動部件、低壓降的實用性多相流提供了借鑒。
  17. ( 4 ) it has succeeded in the technology of a computer spectrum - stabilizing method to solve drift problems in automatic analysis of gamma - ray spectrum. the study of portable gamma - ray data acquisition system is successful

    ( 4 )完成了伽瑪全譜中的軟體穩譜模塊的設,摒棄了性核素源,解決了伽瑪全譜中的譜漂移問題。
  18. Some key factors in design of kev radioactive ion beam facility are discussed. they are extension of primary ion beam line, target / ion source, selection of target materials, optical calculation of the radioactive ion beam system, measurement of weak radioactive ion beam and overall efficiency of the system

    本文介紹了kev性核束裝置中幾個關鍵部分的設和初步實驗結果,包括系統總體概況,初級束流線,靶源系統,靶材料選擇,系統光路,低能性弱束流的性劑及輻防護,系統總體效率評估等。
  19. Under the programme, air, water, foodstuff, soil and other samples are collected and analyzed regularly for their radioactivity content. ambient gamma radiation levels are also measured at a number of places over the territory

    劃內,天文臺定期收集及分析空氣水食物土壤和其他環境樣本,以定其所含性物質的水平,並且在多個地點環境伽馬輻水平。
  20. Radiation protection. radionuclides gauges. gauges designed for permanent installation

    防護.性核素.固定裝置用的
分享友人