故障電弧 的英文怎麼說

中文拼音 [zhàngdiàn]
故障電弧 英文
fault arc
  • : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
  • : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 名詞1. [數學] (圓周的任意一段) arc2. (古代指弓) bow
  • 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
  1. In the simplified model the feeder switches are regarded as the vertexes and the feeder lines as the arcs of a graph

    簡化模型把配網描述為有權的節點和的圖,在此基礎上進行的定位、隔離和恢復處理。
  2. According to the quickly adjustable characteristic of the peterson coil grounding system, this dissertation proposes a new control strategy. when the system is in operation, the strategy can limit the series resonance over - voltage by using the off - resonance method. when fault occurs, the strategy can conveniently suppressing arc by rapidly adjusting the inductance value of the peterson coil to the point, which the resonance with grounding capacitance of the power network is occurred

    依據可控硅控制消線圈接地系統的快速可控性,一改傳統的網正常運行時調節消線圈接近於全補償的預調諧方法,提出正常運行時採用脫諧方法抑制串聯諧振過壓;時立即調節消線圈感量達到與對地容諧振,以利熄的新型調節原理和方法。
  3. New designed auto tracing arc eliminating device based on this technique contents more technology, which has sample circuit, wide tuning scope, quick response and low noise. this paper firstly introduces neutral grounding histroy. by analyzing the syntony grounding theory, the transient and stable process of one - phase grounding fault, the threaten to secure run of power system and the importance of exact compensation for capacitive current are cognized

    論文中首先介紹了中性點接地方式的發展過程,通過對諧振接地原理和單相接地的暫態、穩態分析,認識到接地對系統安全運行的危害,通過消線圈對接地流的迅速準確補償是減小危害的最主要手段。
  4. This paper analyses the usage of lgk series of air plasma arc cutting machine, and enumerates the causes and solutions of striking arc, main circuit, gas path and cutting torch breakdown

    摘要分析了lgk系列空氣等離子切割機的使用方法,例舉了其引、主、氣路、割槍產生的原因和解決方法。
  5. Based on researching the function of every kind of eliminating arc loop, new concept was brought up in this paper, and the protective device for eliminating arc and overvoltage was researched and manufactured. when the arc light connecting the ground emerges, the chip synthesizing controller control the vacuum contacter which can be operated with dividing phase and make its fault phase earthed so that the arc light can be dissolved thoroughly

    本文在研究各種消線圈的基礎上,提出全新的概念,研製出了消及過壓保護裝置,該裝置在出現光接地時,通過單片機綜合控制器控制一組可以分相操作的真空接觸器,使相接地,達到徹底消除光的目的。
  6. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv網接地的形式、消線圈接地的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以纜為主的城區10kv網中性點接地方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際參數來建立數值計算模型,在考慮了網接地流變化、中性點阻取值大小、接地點接地阻值變化等多種影響因素的情況下,對中性點經消線圈接地和經小阻接地方式下網的過壓水平和接地點短路流大小進行了數值計算,其計算結果與科院所作現場試驗進行了比較。
  7. Then the idea of integral control of automatic resonance and single - phase earth faulted line selection was put forward

    並在此基礎上給出了補償網中消線圈自動調諧與單相接地選線一體化的綜合控制思路。
  8. The key process of the algorithm, called nodes transforming to arcs, is based on the calculation loads of coupling nodes and arcs loads from the loads of switch nodes. getting the area of coupling nodes is the most important process in nodes transforming to arcs. this paper presents a new method , which uses the adjacency matrix of distribution network and the information matrix of

    變結構耗散網路是一種新的配網自動化演算法,由配網開關頂點負荷求負荷和耦合頂點負荷的點變換是整個演算法中確定配網饋線區域的基礎,而進行點變換的關鍵就在於分離耦合點區域。
  9. Combined with the practical situiation in distribution network, it ' s suitable to select graph algorithm as the theoretical algorithm base. based on structure variable dissipated network theory, this thesis detailedly discusses the transforms of base - to - shape, shape - to - base, vertex - to - arc, arc - to - vertex, over - heated arc dectection, load allotting, load balancing and optimum restoration

    本論文基於變結構耗散網路理論,詳細討論了基形變換、形基變換、點變換、點變換、過熱搜尋、負荷分配、負荷均衡化以及優化恢復非區域供等一系列與饋線自動化功能相關的處理演算法。
  10. Arc - grounding fault line selection is the paper ' s key point and innovative point about small current grounding power systems. a lot of simulations are made based on the change rule and the character of fault voltage, fault current. the simulation study declare that the use of the method of wavelet analysis can select the fault line when the arc - grounding fault take place, it will play a important directive role in the research of the protection equipment

    對小流接地系統的選線模擬是本文的重點,也是一個創新點,本文從研究的角度,在深入分析接地時壓、流的特點和變化情況的基礎上,進行了大量的選線模擬,模擬表明時,小波分析方法也能準確地選出線路,這對研製高性能的接地保護裝置將起到重要的指導作用。
  11. As the electric power & electronic technology is used widely in low voltage area, the properties of voltage and current in normal working conditions of electrical appliance closely resemble or mimic the un - normal properties created by the arc fault, so it is difficult to distinguish between normal and un - normal cases

    隨著子技術在低壓領域的廣泛應用,一些器正常工作時的流特性與故障電弧的典型特性相似,給檢測工作帶來了難度。
  12. The influences of several factors such as harmonics, intermittent arc grounding, ct, load and fault resistance have been thoroughly analyzed, therefore, it is fundamental work for its application

    深入細致地分析了諧波、間歇流互感器、負荷、過渡阻等多個因素對選線結果的影響,為方案的實用化奠定了基礎。
  13. So the development of self - energy sf6 cb is very important. in the paper, the math model of arc - quenching chamber air - pressure character is built on the base of 126kv / 31. 5ka self - energy sf6 cb ' s exploiting, then the theory analysis and calculation is deeply been done for cylinder radius, nozzle spout radius and opening position of moved contact that they have the essential effect for the use of arc energy in the course of opening. arc - quenching chamber parameter is confirmed according to the request of full opening and fault opening when the cb is opening

    本文針對126kv31 . 5ka自能式sf _ 6斷路器的研製,建立了相應的滅室氣壓特性數學模型,對自能式sf _ 6斷路器開斷過程中能量利用有重要影響的滅室缸徑、噴口直徑、動觸桿開口位置進行了詳細深入的理論分析和計算,並根據斷路器開斷中的滿容量開斷和近區開斷的要求確定了滅室參數。
  14. This layout can stop the internal arc fault expansion ; can avoid harmful moisture, small animal and dusty interferences. it also has good perfomiance and high reliability. because the heat cannot transmit to the outside of the bus room, a good operation environment for the low space can be obtained

    主母線室置於箱體頂部一個單獨的金屬封閉的間隔內,並與10kv開關室、儀表室等間隔相互獨立,為同類產品首創;這種結構可以防止內部的擴大化,避免「火燒聯營」事;防護性能好,防潮、防小動物侵害、防積塵,運行可靠;由於母線室的隔熱作用,為下層空間創造了一個較好的運行環境。
  15. Field circuit breaker failure causing too low arcing voltage followed by blast of ionised air in + es cubicle and flashover at the left extremity of ac bus bars

    導致壓過低的磁場斷路器是引發+ es櫃空氣離和交流母排左側末端處發生閃絡的原因。
  16. After the neutral point is grounded through perterson coil, it can decrease the capacitor current through fault point and the over - voltage caused by the grounding fault, which is advantage for the extinguishments of electric arc

    中性點經消線圈接地后,有效減小了流過點的流,減小了光接地過壓,有利於熄滅。
  17. After the neutral point is grounded through peterson coil, it can decrease the capacitor current through fault point and the over - voltage caused by the grounding fault, which is advantage for the extinguishments of electric arc

    中性點經消線圈接地后,有效地減小了流過點的流,減小了光接地過壓,有利於熄滅。
  18. Fire accident can arise from low - voltage arc fault, and so it is necessary to detect arc fault

    摘要低壓故障電弧有引發火災的危險,所以檢測故障電弧是必要的。
  19. Through studying the principle of dimmer and switch power supply, it was found that in some frequency points, by analyzing the phase of electric voltage and current it can tell if arc faults occur

    研究調光燈及開關源的工作原理可以發現,通過分析迴路中流在某些頻率點的相位信息,可以有效判別是否發生了故障電弧
  20. The break - down arc and its protection in switchgear equipment

    開關設備中的故障電弧及其防護
分享友人